1Conceptpower Modular 80 and 100kVA
THE BEST WAY TO PREDICT THE FUTURE IS TO INVENT IT
2Unique Power Protection Concept (PPC)
6 Key-Features at a Glance
- Modularity
- Redundancy
- Scalability
- Environmentally Friendly
- Serviceability
- Manageability
3ConceptpowerTM Modular
Modularity
- First and unique hot swappable 3phase double
conversion (VFI) UPS modular design - 2 possible power ranges80 and 100kVA
Welcome to the future of power protection
4ConceptpowerTM Module
Front view 80-100kVA
- Active module includes
- Rectifier Booster
- Battery charger
- Inverter
- µProcessor control board
- Passive module includes
- Input filter
- Output filter
- Booster coils
- Static By-pass
5ConceptpowerTM Module
Dry contacts NC/NO, D25P/Fconnection
Smart port RS232
Front view 80-100kVA
By-pass line fuses
EPO, Gen-on, Batt.temp.connector
LCD Display Panelconnector
Module Interfaceconnector
ComBus Module to Module
6ConceptpowerTM Module
Rear view 80-100kVA
Weight of the passive module 80-100 kVA 55-60
Kg Size of the UPS module667x412x834mm (WxHxD)
Weight of the active module 80-100 kVA 55-60
Kg Size of the UPS module667x412x834mm (WxHxD)
7ConceptpowerTM Module
Inside view 80-100kVA
µ Control board
Batt. Charger
Input LC FIlter
By-pass
Inverter
Booster
DC Cap.
Output LC Filter
8ConceptpowerTM Modular
Power modules 80-100 kVA
Upgrade frame 300 kVA
Welcome to the future of power protection
9ConceptpowerTM Modular
UPGRADE FRAME
Power modules 80-100kVA
- Limited up to 10 modules in parallel (gt 10
modules on request)
- Distribution section for the max. capacity
(300kVA)
- No single point of failure
- Space saving, 300kVA in 1.22 sqm.
10ConceptpowerTM Modular
UPGRADE FRAME DISTRIBUTION 300KVA
Modules output disconnects
Centralized SNMP Slot (Multidrop).
RS232, PFC, EPO
DPA extension bus
Centralized MaintenanceBy-pass
11ConceptpowerTM Modular - Scalability
- Optimized capital investment by extending your
power protection capacity at a pace that fits
your business on demand - Scalable performance of the power capacity and
runtime by simply adding independent UPS or
battery increments
Upgrade Frame (Vertical Scalability) (floor-saving
-frame)
12ConceptpowerTM Modular Environmentally Friendly
- Sinewave input current (THD7-9)
- Input PF0.98 in a standard versionThis
means - Smaller cables size and lower losses
- Smaller fuses or Circuit Breakers (no
malfunction and false tripping) - No separate phase compensation required
- No extra heating of transformer and generators
oversized
No additional hardware for harmonic reduction is
required
13ConceptpowerTM Modular Environmentally Friendly
- Highest double-conversion efficiency ESIS (Energy
Saving Inverter Switching) up to 95 in on- line,
double conversion mode - Load dependent audible noise
- Wide input frequency windows (35-70Hz)
- Low weight (3x100kVA 700kg)
- Compact size (3x100kVA 1.22 sqm)
The total annual operating costs for a Newave
UPS can be gt40 less compared to those for a
previous generation
14ConceptpowerTM Modular Environmentally Friendly
Product positioning Case 1 configuration
required 2x200kVA redundant
15ConceptpowerTM Modular Environmentally Friendly
Product positioning Case 2 configuration
required 2x500kVA redundant
16Battery cost saving
- Flexible Battery Management (FBM)
- Variable DC-voltage enabling the use of battery
blocks (40-50 blocks of 12VDC) - Wide input voltage windows (-23/15 _at_100
load) (-30/15 _at_lt80 load)
(-40/15 _at_lt60 load) Less need for battery
operation - Automatic battery test with algorithm CPU
controlled Early warning in case of battery
fault - Temperature compensation Increases battery
lifetime - Ripple free through battery charger Longer
battery life time
17ConceptpowerTM Modular Serviceability
- Modular and hot-swappable design means minimizing
service and maintenance cost and - Reduction of MTTR, maximize your power
protectionavailability - Front access only
- No needs for skilled personnel on site
- No need of spares, just modules
18ConceptpowerTM Modular Manageability
- Redundant Power Management Display advances the
Power Protection Manageability - Common data execution functions for parallel
systems on redundant parallel PMDs. - The complete parallel system may be managed by
any one of the parallel PMDs. - PMD consists of mimic diagram for system status,
push buttons for single module and parallel
system control and LCD for monitoring, event logs
and diagnosis.
19ConceptpowerTM Module Display
Most important information available at first
glance
20ConceptpowerTM Modular Remote Control and
Shutdown
- Remote Signalling Panel (RSP)For Status and
Alarm Remote Indications - Wavemon (CD)For Automatic Server shutdownand
Monitoring. Cross Platform shutdown available - SNMP-card or Box for connection of UPS in Network
Management systems
2110 reasons for buying ConceptpowerTM Modular
1. Optimize capital investment and available
space Pay-as-you-grow solution lowers your
capital costs and increases utilization rates,
while innovative rack-based technology frees up
space previously needed for infrastructure
support. 2. Adapt to ever-changing power
requirements No need to abandon previous
investment when power density needs increase or
if physically moving your data centre. Adapt to
changing wattage requirements in your racks with
single- or multi-branch rack-mount power
distribution units. 3. Accelerate speed of
deployment Electrical and physical modularity
allows for rapid installation with minimal
engineering. 4. Lower the cost of service
contracts Simplicity of system design and
intelligent modular parts lessen the dependency
on expensive service contracts. 5. Increase
availability Specifically engineered to deliver
higher availability through proactively designed,
building block architecture and reduced MTTR
2210 reasons for buying ConceptpowerTM Modular
6. Decrease mean-time-to-recovery (MTTR)
Compartmentalize potential failures with system
components consisting of intelligent,
maintainable modules for quick fault
recovery. 7. Plan for a power density that is
increasing and unpredictable Eliminate hot spots
in your data centre caused by higher power
densities by targeting availability where you
need it most. 8. Minimize points of failure
between the UPS and the critical load Move
redundancy closer to the load and prevent the
majority of failures that cause critical load
downtime. 9. Minimize human error Simplicity of
design and intelligent modules increase system
availability by mitigating human error the
number one cause of critical load downtime. 10.
Decrease the operating costs With efficiency up
to 95 (double conversion mode), the operating
costs for a Conceptpower modular UPS can be gt40
less compared to those for a previous generation
23Power Protection Leader Through Innovation