Lesson Title
DAGR Operational Checkout
Lesson Number
113-002
2
LESSON OBJECTIVES
  • Perform the DAGR Operational Checkout procedure.

3
OVERVIEW
  • Introduction
  • Operational Checkout Procedure Familiarity
  • Pretest setup
  • Operations
  • Perform the DAGR Operational Checkout Procedure

4
OVERVIEW
  • Page Function
  • SV Sky View Page Function
  • Channel Status Page Function
  • SV Status Page Function
  • SV Message Page Function
  • DOP Calculation Page (Advanced) Function
  • SV Schedule Page (Advanced) Function
  • SV Select Page Function

5
DAGR OPERATIONAL CHECKOUT
  • Operational Checkout
  • Determines if Operating Correctly
  • Aids in detecting DAGR Malfunctions

6
DAGR OPERATIONAL CHECKOUT
  • Pretest Setup
  • WARNING
  • Lithium batteries can explode
  • Reverse polarity can cause damage to the battery
    and receiver
  • CAUTION
  • Do not mix battery type
  • DAGR Used for Time
  • DAGR Resets to Default
  • External DC Power

7
DAGR OPERATIONAL CHECKOUT
  • Note
  • Clear View of Sky
  • Display Heater
  • No Pretest Connections or Adjustments
  • External Power Source with Host Platform mount

8
DAGR OPERATIONAL CHECKOUT
  • Ref Para 18.3
  • Operational Checkout
  • Inspect the DAGR and external cables and
    equipment for damage and/or missing parts.
    (Refer to the parts list for associated parts
    used.)
  • b. Push the POWER key to turn the DAGR on, and
    make sure the DAGR or DAGR system antenna has a
    clear view of the sky.
  • c. During power up, observe the power-on status
    display. Make sure that self-test passes and
    battery indication batteries not applicable to
    system installation shows sufficient battery
    power left. Do not use the DAGR if a failed
    self-test is indicated.

9
DAGR OPERATIONAL CHECKOUT
  • d. After the DAGR successfully completes power-on
    self-test and shows the SV Sky View page or
    Present Position page, perform the following
    procedure for an operator induced commanded
    self-test.
  • Note
  • List of Passed and Failed tests

10
DAGR OPERATIONAL CHECKOUT
  • Note
  • Self-test does not track SV
  • Activate commanded DAGR self-test.
  • (a) If the Present Position page is not
    already displayed, push and hold the POS key
    (except when showing a message pop-up, then push
    the QUIT key first). The Present Position page is
    displayed.
  • (b) From the Present Position page, push the
    MENU key.

11
DAGR OPERATIONAL CHECKOUT
  • (c) Highlight Select Op Mode, then push the ENTER
    key.
  • (d) Highlight Test, then push the ENTER key.
  • (e) The DAGR displays an ENTER TEST MODE message
    prompting the operator to confirm or cancel
    entering test mode. Push ENTER key to confirm.

12
DAGR OPERATIONAL CHECKOUT
  • (2) Test In Progress display appears with
    specific area of testing listed at bottom and a
    bar graph denoting progress. The DAGR
    automatically tests multiple areas.

13
DAGR OPERATIONAL CHECKOUT
  • Note
  • Test ENTER key
  • (3) After the test in progress tests are
    completed, Keypad Test is displayed. Push each
    key on the keypad and verify the corresponding
    key shown on the display toggles between normal
    and highlighted appearance. Push the ENTER key to
    continue to the next display.

14
DAGR OPERATIONAL CHECKOUT
  • (4) Display Light Test display appears with the
    brightness adjustment cycling between 0 and
    100. The percentage adjustment is reflected in
    the light bulb of the display. Verify the display
    lighting by viewing the DAGR display in a dark
    area. Push ENTER key to continue.

15
DAGR OPERATIONAL CHECKOUT
  • (5) Contrast Test display appears with the
    contrast adjustment cycling between 0 and 100.
    The percentage adjustment is reflected in the bar
    graph of the display. Push ENTER key to continue.

16
DAGR OPERATIONAL CHECKOUT
  • (6) The Display Test Beginning message appears
    momentarily. After sequencing through white,
    light gray, dark gray, and black, the Display
    Test Completed message appears, followed by the
    Power-On Status display listing self-test results
    as Pass or Fail.

17
DAGR OPERATIONAL CHECKOUT
  • Note
  • Push and Hold ENTER key
  • (7) If Power-On Status remains displayed and
    does not time out, push the ENTER key to
    acknowledge.
  • (8) The SV (Satellite Vehicle) Sky View page is
    displayed.

18
DAGR OPERATIONAL CHECKOUT
  • e. With the SV Sky View page displayed, push
  • the MENU key.
  • Highlight Select Op Mode, then push the ENTER
    key.
  • g. Highlight Continuous, then push the ENTER key.
    This mode enables the DAGR to acquire a current
    position fix.
  • h. After satellites are acquired and a current
    position fix is obtained, the DAGR display stops
    blinking and Navigate SVs is shown on the SV Sky
    View page, then automatically switches to the
    Present Position page.

19
DAGR OPERATIONAL CHECKOUT
  • Note
  • Display Blinks
  • i,. Do the following before using the DAGR
  • Ensure the correct function set is being used
  • Ensure the correct user profile is being used
    if using the advanced function set.
  • Set the DAGR to the desired operating mode.

20
SKY VIEW PAGE
  • Ref. Para 13.2.3
  • 1. From any display (except a message pop-up),
    push the MENU key twice to display the Main Menu.
  • 2. Highlight Satellite, then push the ENTER key.
  • 3. Highlight SV Sky View, then push the ENTER
    key. The SV Sky View page is displayed.

21
PAGE FUNCTION
  • Sky View Page
  • Graphical Status Information
  • Signal Strength Information
  • Satellite Positions
  • Current Status
  • VIS
  • GOOD
  • ALM AGE
  • Almanac Data
  • Current Operating Mode

22
PAGE FUNCTION
  • Channel Status Page
  • Satellite Data for Active Channels
  • SV
  • C/No
  • CODE
  • FREQ
  • J/I

23
PAGE FUNCTION
  • SV Status Page
  • Status of visible satellites
  • SV
  • AZ
  • ELA
  • SET
  • HLTH

24
PAGE FUNCTION
  • SV Message Page
  • Almanac Age
  • Healthy Satellite Data
  • Satellite Special Messages

25
PAGE FUNCTION
  • DOP Calculation Page
  • Best and Worst Times
  • Note
  • Data Lost

26
PAGE FUNCTION
  • SV Schedule Page
  • Note
  • Data Lost
  • Satellite Visibility

27
PAGE FUNCTION
  • SV Select Page
  • - CAUTION -
  • Performance Degraded
  • Select
  • satellite frequencies
  • codes
  • acquisition methods
  • Deselect satellites

28
CHECK ON LEARNING
  • The Operational Checkout is designed to do what?
  • It is designed to show whether the unit is
    operating correctly or not.
  • True or False
  • The DAGR needs a clear view of the sky in
    order to do a successful operational checkout.
  • True
  • True or False
  • Do not use the DAGR if a failed self-test is
    indicated.
  • True
  • Where is the DOP Calculation Page accessed from?
  • It is accessed from the Satellite submenu.