STYLITIS-41 - PowerPoint PPT Presentation

About This Presentation
Title:

STYLITIS-41

Description:

STYLITIS-41 is suitable for measurements in Meteorological, Wind/Hydro potential and other Environmental fields 1. MAIN FEATURES 7 channels, and specifically ... – PowerPoint PPT presentation

Number of Views:33
Avg rating:3.0/5.0
Slides: 26
Provided by: JohnBa170
Category:

less

Transcript and Presenter's Notes

Title: STYLITIS-41


1
STYLITIS-41
  • is suitable for measurements in Meteorological,
    Wind/Hydro potential and other Environmental
    fields

2
1. MAIN FEATURES
  • 7 channels, and specifically
  • - 3 Counter Channels (types SIN, 40
    (SIN with filter), TTL or REED). - 4
    Analog Channels 2 with no gain (05V sensors
    supported)
    2 with gain (standard-by request) as
    well.
  • Sampling once per second.
  • Math statistics (Average, Min, Max, Sdv) recorded
    per interval (from 1 min to 1 hour).
  • Recording in internal memory of 512KB (buffer) or
    in Removable Compact Flash Cards (up to 2GB) for
    practically unlimited data storage.
  • 1 serial communication port (DCE).
  • 5 Precision voltage (5V) excitation outputs 3
    Pulsed and 2 Fixed.

3
2. PHYSICAL FORM AND SHELTER BOX
  • Stylitis-41 features
  • Control
  • LCD display and 16-key numeric keyboard local,
    full operation except data download.
  • Total control and more user friendly operation
    via our Stylitis Explorer software.
  • Serial Port/Communication 1 serial communication
    port (DCE), suitable for
  • Local Operation, by connecting it to a PC
  • Remote operation, by connecting it to an external
    GSM modem or to a Sym-o-net modem (Symmetrons
    modem for GPRS operation and encrypted data
    emailing).
  • Internet/LAN operation, by connecting it to an
    external Serial-to-Ethernet Adaptor.
  • ENCLOSURE ??65 sealed.
  • DIMENSIONS 31 x 21,5 x 17,5cm, WEIGHT 4kg.
  • INPUT CONNECTORS Removable screw terminal strips
    on right side.
  • SHELTER BOX (Optionally, if the logger is used
    for outdoor use, in harsh environments)
  • Any IP65 box should be OK
  • Advised minimum dimensions 50x40x20 cm
  • In the Shelter box, you can additionally install
    other accessories of yourmeasuring system, such
    as a lead acid battery and a charge controller
    (connected with a solar panel) for the systems
    power supply

4
3. SCREEN AND KEYBOARD
  • Stylitis-41 has an LCD screen and a 16-button
    keyboard, via which all main operations except
    data downloading can be performed. Specifically,
    via the screen and keyboard you can
  • View instantaneous channel values.
  • View and change logger time, password and
    recording interval.
  • Change the channels setup.
  • View certain information regarding the loggers
    status card and buffer status and recording time
    remaining, f/w version, battery voltage.
  • Change the acquisition status (ON/OFF).
  • View the internal modems signal strength (if it
    is in GSM data mode).
  • However, Stylitis-41s free operating software,
    Stylitis Explorer, is more user friendly and
    enables more advanced operations, such as easier
    and more advanced setup, while data can also be
    downloaded. However, a virtual screen and
    keyboard are also available via the software.

5
4. COMPATIBLE COUNTER SENSORS (EXAMPLES)
  • Stylitis-41 supports a wide variety of
    measurements and sensors.
  • Indicatively, some counter sensors are
  • and many more

MEASUREMENT SENSORS
Wind Speed Horizontal NRG 40, 40H YOUNG 05103 Wind Speed Sensor Vector A100-L2, -R, -K, -LM Thies First Class Anemometer
Electrical energy Revalco 1RCEM series ABB ODIN4165
Rain Height NRG RainGage Vector Tipping Bucket
6
5. COMPATIBLE ANALOG SENSORS (EXAMPLES)
  • Indicatively, some analog sensors are
  • and many more

MEASUREMENT SENSORS
Wind Direction NRG 200P Vector W200P Thies First Class Wind Vane Young 05103 Wind Direction Sensor
Temperature/Humidity Temperature Vector T351, etc (PT-100), NRG 110S Humidity NRG RH5 Both sensors DeltaOhm HD9009TR
Barometric Pressure Vaisala PTB10- series, PTB210- series NRG BR20 Setra 276, Apogee SB-100
Solar Radiation LiCor LI-200SA, Skye SKS-1110 KippZonen CMP series Apogee SP-110, SP-212, SP-215
7
6. COMMUNICATION METHODS
  • Communicate with the datalogger via Stylitis
    Explorer, its operating software, in various
    ways. The datalogger can be used
  • On its own, for local operation
  • Locally
  • With a serial-to-Ethernet adaptor, connected to
    its serial port, for Ethernet operation
  • Via Ethernet
  • With an external GSM/GPRS modem and other types
    of modems (which do not require a SIM card),
    connected to its serial port, for remote
    operation
  • Via GPRS, using a cheap Dynamic IP SIM Card (via
    Diameson Server)
  • Via GPRS, using a static IP SIM Card
  • Via a GSM data call.
  • Via Satellite
  • Via RF modems
  • Measuring network via RF modems
  • Remote measuring network via RF modems
  • The communication methods are presented more
    analytically in the next chapters.

8
7. LOCAL COMMUNICATION
  • Locally


  • RS-232
  • Connect via a straight serial cable your computer
    COM port to the loggers serial port.

Stylitis-41
9
17. ETHERNET COMMUNICATION
  • 2. Via Ethernet (local network or the
    internet)
  • RS-232
  • Connect a Serial-to-Ethernet adaptor to the
    dataloggers serial port.
  • Connect the Ethernet port to a LAN or to the
    internet.
  • An ADSL connection (a static IP) for the logger
    is required only to connect the logger to the
    internet.

LAN/ internet
Serial-to-Ethernet
ADSL Router
Stylitis-41
10
8. GPRS COMMUNICATION VIA DYNAMIC IP SIM
  • 3. Via GPRS, using a cheap Dynamic IP SIM Card
    (via Diameson Server)
  • RS-232

    Virtual
    COM
  • Connect Stylitis-41s serial port to the DEVICE1
    port of a Sym-o-net modem, set to GPRS client
    mode, via a NULL MODEM cable.
  • Neither ADSL (static IP) connection is required
    for the logger nor expensive static IP SIM cards.
  • A cheap dynamic IP GPRS SIM card is required.
  • Low operation cost The Sym-o-net is permanently
    online, but only data exchange is charged.
  • Sym-o-nets and Computers are connected as clients
    to Diameson Gateway, Symmetrons server software.
  • Symmetrons Diameson is available for
    connections, but you can use your own Diameson,
    to manage your own Sym-o-nets.

GPRS Network
Sym-o-net modem
Diameson Gateway
Internet
Stylitis-41
11
9. GPRS COMMUNICATION VIA STATIC IP SIM
  • 4. Via GPRS, using a static IP SIM Card
  • RS-232


    Virtual COM
  • Connect Stylitis-41s serial port to the DEVICE1
    port of a Sym-o-net modem, set to GPRS server
    mode, via a NULL MODEM cable.
  • A GPRS static IP SIM card is required.
  • Again, only data exchange is charged.
  • The Sym-o-net acts like a server, and the
    computer connecting to it acts as its client.

GPRS Network
Sym-o-net modem
Internet
Stylitis-41
12
10. GSM COMMUNICATION
  • 5. Via a GSM data call
  • RS-232

    RS-232
  • Connect one GSM modem to the dataloggers serial
    port and one to a computer COM port.
  • Call the loggers modem, provided that both
    modems SIM cards support GSM data calls.

GSM Network
GSM modem
Stylitis-41
GSM modem
13
11. SATELLITE COMMUNICATION
  • 6. Via Satellite
  • RS-232

    RS-232
  • Two satellite iridium modems are required, one
    connected to the computer and one to the
    dataloggers serial port.
  • Communication is achieved via satellite.

Stylitis-41
Iridium modem
Iridium modem
14
12. RF COMMUNICATION
  • 7. Via RF modems

  • RS-232
    RS-232
  • Connect one RF Modem to Stylitis-41s serial port
    and one to the computers COM port.
  • Achieve remote connections without a SIM card,
    for a limited distance (usually a few kilometers)
    between modems.

Radio Modem
Radio Modem
Stylitis-41
15
12. COMMUNICATION VIA RF NETWORK
  • 8. Measuring network via RF modems
  • RS-232


  • RS-232
  • RS-232
  • Capability of communication with multiple
    dataloggers (one at a time), by using an RF modem
    for the computer (as a Master) and one for each
    datalogger (as Slaves).
  • Again the distance between the Master modem and
    each Slave modem is limited (usually a few
    kilometers).
  • Each datalogger modem is set to have a unique
    address. Communicate with one at a time.

Stylitis-41
Radio Modem
Radio Modem
Radio Modem
Stylitis-41
16
13. COMMUNICATION VIA REMOTE RF NETWORK
RS-232 RS-232
  • 9. Remote measuring network via RF modems

Stylitis-41
  • Same method as before, with the difference that
    the modem network can be remote, regarding the
    computer.
  • The Master modem can be accessed via the GPRS
    network via Symmetrons Sym-o-net modem.
  • Sym-o-net, as stated in previous chapters can
    connect as a client to Diameson Gateway, via a
    dynamic IP SIM card.
  • Again the distance between the Master modem and
    each Slave modem is limited (usually a few
    kilometers).

  • Virtual
    COM

Radio Modems
  • RS-232

GPRS Network
Internet
Diameson Gateway
Sym-o-net
17
18. STYLITIS EXPLORER STARTING UP
  • Stylitis Explorer is Stylitis-41s free operating
    software.
  • Start up with Stylitis Explorer, by creating Site
    folders and Connections.
  • Create one unique site folder for each
    datalogger.
  • In each site folder, multiple (different types
    of) connections can be created for the logger.
    The different connection types correspond to the
    communication methods, discussed before.
  • The connections created are saved as windows
    files, which are recognized by Stylitis Explorer
    in a folder interface, along with the compressed
    and decompressed data files (see Chapter 20), and
    setup files, ie logger settings (see next
    Chapter) saved in a file.
  • There is also a user friendly way to manage and
    view a list of all the created sites and go to a
    specific site with a double-click. View
    statistics, such as last connection and download
    (manual and automatic).
  • Refer to the corresponding screen shot in Chapter
    22.
  • After achieving a connection, you can communicate
    with the logger. Besides changing logger and
    Sym-o-net modem (if used) settings and download
    data, you can view some features, and
    specifically
  • View the loggers status Instant parameters,
    such as the date and time, the battery voltage,
    the current data file being recorded, the
    recording time remaining in the buffer and in the
    card, etc.
  • View an Online plot of the selected channels
    values. All samples are plotted (every second).
    Appropriate units appear on the plot.Refer to
    the corresponding screen shot in Chapter 22.
  • Via the virtual keyboard, navigate in the
    loggers menus to view the instant channel values
    and the status parameters one by one.

18
19. STYLITIS EXPLORER SETUP
  • Connect to the datalogger, via Stylitis Explorer,
    via one of the connections you created and modify
    its setup, ie settings such as the recording
    interval (selectable from 1 min to 1 hour) and
    the loggers site name. However, the main
    settings to be adjusted are the channel settings.
  • CHANNEL SETTINGS
  • The settings of all channels can be changed in
    two ways
  • Manually. Change settings manually. Manual setup
    can be done either via a virtual keyboard, by
    navigating in the loggers menus or via the user
    friendly Easy Setup (see Chapter 22 for screen
    shot)
  • Select mode. For counter channels select Counter,
    Frequency or Events. For analog ones, select
    Analog, PT-100 or Vane.
  • Select type. For counter channels, select TTL,
    REED, SIN or 40 (SIN with filter). For Analog
    channels A3, A4, enable/ disable the gain (which
    is standard, by request).
  • Type the Slope and Offset parameters.
  • Via Stylitis Explorers Sensor Library. Via Easy
    Setup again, instead of changing the settings
    manually, you can select a specific measurement
    and then a specific sensor, related to this
    measurement. Optionally, also change the
    measuring units. All settings are updated
    automatically.
  • SYM-O-NET SETTINGS
  • Sym-o-net is Symmetrons GPRS modem which can
    cooperate with Stylitis-41. If you are using it,
    adjust its settings via Sym-o-net Programmer, an
    add-on software to Stylitis Explorer. The
    settings to be adjusted are
  • Selection of the modems operation, defining the
    type of the remote connection, as discussed in
    previous chapters GSM data mode, GPRS client
    mode (via Diameson server) or GPRS server mode.
  • SMS cellphone number (optionally). An alarm SMS
    is sent if the power supply is found below 11V.
  • GPRS settings, if GPRS operation is selected. SIM
    card provider settings APN, User Name, Password.
    Diameson settings IP address and Device
    Listening port.
  • Email settings. Enable or disable encrypted
    (according to the password) data emails at least
    once a day. Define the SMTP mail server, sender,
    recipient and if the SIM card provider requires
    authentication, type the email accounts User
    Name and Password.
  • Peripheral Schedule. Define between what hours of
    the day the datalogger and Sym-o-nets
    DEVICE2and DEVICE3 will be available for remote
    communication (and the modem will be turned on).

19
20. STYLITIS EXPLORER ACQUISITION AND DOWNLOAD
  • After writing the desired setup in the
    datalogger, enable data acquisition to start
    recording. Data is recorded in compressed form,
    in two ways
  • In the loggers internal 512KB memory (buffer).
    Only the current file is stored in the buffer, ie
    if you set AcquisitionOFF, the buffer is cleared
    and data are lost.
  • In a removable Compact Flash card (up to 2GB).
    The data storage is practically unlimited.
    Multiple data files can be stored in the card. A
    new file begins when downloading the current file
    or disabling and re-enabling the acquisition.
  • When downloaded, a compressed file is
    decompressed into a data file, which can be
    viewed via a text editor. Compressed and
    decompressed data files are stored in the
    loggers site folder, as mentioned in Chapter 18.
  • Data download can be achieved either manually or
    automatically via AutoConnect software (see
    Chapter 24).
  • MANUAL DOWNLOAD
  • From the buffer. Download the current file. In
    the end, you will be asked if you wish to clear
    the buffer and begin a new file or not (the same
    file will continue to grow).
  • From the Compact Flash. There are 3 download
    options when you are using a Compact Flash
  • Download the most recent file. If Acquisition is
    ON, this is the current file. In this case, the
    current file is firstly closed (the next file
    begins) and then downloaded.
  • Download the cards directory. This way all the
    cards files (the last 256 ones) appear with
    their number, start date and size. The directory
    is also saved in a text file in the site folder.
  • Download a previous file, by typing their number.
    Again, the last 256 files are available. To
    download all previous files, retrieve the card
    and read it via a card reader.

20
21. STYLITIS EXPLORER OFFLINE DATA MANAGEMENT
  • After downloading the data files in the site
    folder, you can manage them offline. Stylitis
    Explorer offers some useful tools for offline
    management and presentation
  • Plot. View the selected channels plot, in up to
    3 graph groups. View values at a specific moment
    with the channel units.Refer to the
    corresponding screen shot in Chapter 23.
  • Data File Processing. Check the integrity of a
    folders files, ie check for missing or duplicate
    records or if the interval is the same for all
    files.
  • Statistics. Statistics of the files data can
    appear per hour, per day, per month and per year.
    Statistics include be the average values of the
    data (within the hour, day, month or year), the
    max, min or sdv values, or sum of all values.
    They are presented via a bar graph or a dot
    plot.Refer to the corresponding screen shot in
    Chapter 23.
  • Data Availability. View the percentage of the
    available data of a site folder within the years,
    in which there are data. For a specific year,
    view the corresponding percentage within its
    months.Refer to the corresponding screen shot in
    Chapter 23.
  • Convert data file parameters. Apply new Slope and
    Offset values in a downloaded file in retrospect
    and create a new file.
  • Export to WindRose/Excel/.CSV/.TAB file. Export a
    files data to an Excel, a comma delimited or a
    tab delimited file. Especially for wind data
    (speed and direction channels), you can export
    them to WindRose, the wind analysis software,
    add-in to the Microsoft Excel, which is
    manufactured by CRES and distributed by
    Symmetron.For WindRose, refer to the
    corresponding screen shot in Chapter 23.

21
22. STYLITIS EXPLORER SCREEN SHOTS (PART 1)
  • Site folders and
    files interface

    Online plot

22
23. STYLITIS EXPLORER SCREEN SHOTS (PART 2)
  • Data
    availability

    Data file plot

23
24. AUTOCONNECT SOFTWARE
  • As stated before, data files can be downloaded
    manually, via Stylitis Explorer, via any
    connection.
  • However, data download, along with other actions
    as well, can be preformed automatically, in a
    regular basis, via the additional free software
    AutoConnect.
  • The datalogger can perform a different action
    each weekday
  • Download Data The current data file, either from
    the buffer or from theCompact Flash. There is an
    option to clear the buffer in the end or not.
  • Download Status Instant parameters, such as the
    current file, the recording time remaining, etc.
  • Download Display. Get the instant channel values.
  • Update Captum. Captum is a free service to
    present real-time and historical data of
    Symmetron data loggers on the World Wide Web.



  • Captum Plot
  • The selected action of a weekday can be performed
    once a day at a specific selected time, or
    infinite connections can be made that weekday
    every as many minutes as you wish.
  • Besides editing the auto connections (like in
    Stylitis Explorer) via AutoConnects interface,
    you can
  • View a list of all your automatic connections and
    execute one or more manually.
  • Check each connections latest status, ie if it
    succeeded, or failed and why.
  • View the date and time of last connection and
    last successful download for each one.

24
25. MAIN APPLICATIONS AND CONCLUSION
  • Stylitis-41 could be used in
  • Wind energy assessment.
  • Solar plant monitoring.
  • Weather stations.
  • Electrical Measurements.
  • and many more
  • Summing up, its main advantages are
  • Specialized in wind/hydro measurements.
  • Variety of sensor types supported, along with
    suitable voltage excitation outputs.
  • Variety of communication methods.
  • Free operating and automatic connection software.

25
about Symmetron
  • Our company was founded in 1989 by experienced
    engineers and evolved as a major manufacturer of
    dataloggers and supplier of measurement
    equipment. Symmetron is certified according to
    the ISO9001 quality system and we are proud to
    have deployed thousands of measurement systems
    worldwide.
  • Address
  • 1, Antikythiron Street
  • 153 44 Gerakas
  • Greece tel 30-210-6034002fax 30-210-6034003
    email info_at_symmetron.grwww.symmetron.gr
Write a Comment
User Comments (0)
About PowerShow.com