Title: STYLITIS-41
1STYLITIS-41
- is suitable for measurements in Meteorological,
Wind/Hydro potential and other Environmental
fields
21. MAIN FEATURES
- 7 channels, and specifically
- - 3 Counter Channels (types SIN, 40
(SIN with filter), TTL or REED). - 4
Analog Channels 2 with no gain (05V sensors
supported)
2 with gain (standard-by request) as
well. - Sampling once per second.
- Math statistics (Average, Min, Max, Sdv) recorded
per interval (from 1 min to 1 hour). - Recording in internal memory of 512KB (buffer) or
in Removable Compact Flash Cards (up to 2GB) for
practically unlimited data storage. - 1 serial communication port (DCE).
- 5 Precision voltage (5V) excitation outputs 3
Pulsed and 2 Fixed.
32. PHYSICAL FORM AND SHELTER BOX
- Stylitis-41 features
- Control
- LCD display and 16-key numeric keyboard local,
full operation except data download. - Total control and more user friendly operation
via our Stylitis Explorer software. - Serial Port/Communication 1 serial communication
port (DCE), suitable for - Local Operation, by connecting it to a PC
- Remote operation, by connecting it to an external
GSM modem or to a Sym-o-net modem (Symmetrons
modem for GPRS operation and encrypted data
emailing). - Internet/LAN operation, by connecting it to an
external Serial-to-Ethernet Adaptor. - ENCLOSURE ??65 sealed.
- DIMENSIONS 31 x 21,5 x 17,5cm, WEIGHT 4kg.
- INPUT CONNECTORS Removable screw terminal strips
on right side. - SHELTER BOX (Optionally, if the logger is used
for outdoor use, in harsh environments) - Any IP65 box should be OK
- Advised minimum dimensions 50x40x20 cm
- In the Shelter box, you can additionally install
other accessories of yourmeasuring system, such
as a lead acid battery and a charge controller
(connected with a solar panel) for the systems
power supply
43. SCREEN AND KEYBOARD
- Stylitis-41 has an LCD screen and a 16-button
keyboard, via which all main operations except
data downloading can be performed. Specifically,
via the screen and keyboard you can - View instantaneous channel values.
- View and change logger time, password and
recording interval. - Change the channels setup.
- View certain information regarding the loggers
status card and buffer status and recording time
remaining, f/w version, battery voltage. - Change the acquisition status (ON/OFF).
- View the internal modems signal strength (if it
is in GSM data mode). - However, Stylitis-41s free operating software,
Stylitis Explorer, is more user friendly and
enables more advanced operations, such as easier
and more advanced setup, while data can also be
downloaded. However, a virtual screen and
keyboard are also available via the software.
54. COMPATIBLE COUNTER SENSORS (EXAMPLES)
- Stylitis-41 supports a wide variety of
measurements and sensors. - Indicatively, some counter sensors are
- and many more
MEASUREMENT SENSORS
Wind Speed Horizontal NRG 40, 40H YOUNG 05103 Wind Speed Sensor Vector A100-L2, -R, -K, -LM Thies First Class Anemometer
Electrical energy Revalco 1RCEM series ABB ODIN4165
Rain Height NRG RainGage Vector Tipping Bucket
65. COMPATIBLE ANALOG SENSORS (EXAMPLES)
- Indicatively, some analog sensors are
- and many more
MEASUREMENT SENSORS
Wind Direction NRG 200P Vector W200P Thies First Class Wind Vane Young 05103 Wind Direction Sensor
Temperature/Humidity Temperature Vector T351, etc (PT-100), NRG 110S Humidity NRG RH5 Both sensors DeltaOhm HD9009TR
Barometric Pressure Vaisala PTB10- series, PTB210- series NRG BR20 Setra 276, Apogee SB-100
Solar Radiation LiCor LI-200SA, Skye SKS-1110 KippZonen CMP series Apogee SP-110, SP-212, SP-215
76. COMMUNICATION METHODS
- Communicate with the datalogger via Stylitis
Explorer, its operating software, in various
ways. The datalogger can be used - On its own, for local operation
- Locally
- With a serial-to-Ethernet adaptor, connected to
its serial port, for Ethernet operation - Via Ethernet
- With an external GSM/GPRS modem and other types
of modems (which do not require a SIM card),
connected to its serial port, for remote
operation - Via GPRS, using a cheap Dynamic IP SIM Card (via
Diameson Server) - Via GPRS, using a static IP SIM Card
- Via a GSM data call.
- Via Satellite
- Via RF modems
- Measuring network via RF modems
- Remote measuring network via RF modems
- The communication methods are presented more
analytically in the next chapters.
87. LOCAL COMMUNICATION
- Locally
-
RS-232 - Connect via a straight serial cable your computer
COM port to the loggers serial port. -
-
Stylitis-41
917. ETHERNET COMMUNICATION
- 2. Via Ethernet (local network or the
internet) -
- RS-232
-
- Connect a Serial-to-Ethernet adaptor to the
dataloggers serial port. - Connect the Ethernet port to a LAN or to the
internet. - An ADSL connection (a static IP) for the logger
is required only to connect the logger to the
internet.
LAN/ internet
Serial-to-Ethernet
ADSL Router
Stylitis-41
108. GPRS COMMUNICATION VIA DYNAMIC IP SIM
- 3. Via GPRS, using a cheap Dynamic IP SIM Card
(via Diameson Server) - RS-232
Virtual
COM - Connect Stylitis-41s serial port to the DEVICE1
port of a Sym-o-net modem, set to GPRS client
mode, via a NULL MODEM cable. - Neither ADSL (static IP) connection is required
for the logger nor expensive static IP SIM cards. - A cheap dynamic IP GPRS SIM card is required.
- Low operation cost The Sym-o-net is permanently
online, but only data exchange is charged. - Sym-o-nets and Computers are connected as clients
to Diameson Gateway, Symmetrons server software. - Symmetrons Diameson is available for
connections, but you can use your own Diameson,
to manage your own Sym-o-nets.
GPRS Network
Sym-o-net modem
Diameson Gateway
Internet
Stylitis-41
119. GPRS COMMUNICATION VIA STATIC IP SIM
- 4. Via GPRS, using a static IP SIM Card
- RS-232
Virtual COM - Connect Stylitis-41s serial port to the DEVICE1
port of a Sym-o-net modem, set to GPRS server
mode, via a NULL MODEM cable. - A GPRS static IP SIM card is required.
- Again, only data exchange is charged.
- The Sym-o-net acts like a server, and the
computer connecting to it acts as its client. -
GPRS Network
Sym-o-net modem
Internet
Stylitis-41
1210. GSM COMMUNICATION
- 5. Via a GSM data call
- RS-232
RS-232 - Connect one GSM modem to the dataloggers serial
port and one to a computer COM port. - Call the loggers modem, provided that both
modems SIM cards support GSM data calls.
GSM Network
GSM modem
Stylitis-41
GSM modem
1311. SATELLITE COMMUNICATION
- 6. Via Satellite
- RS-232
RS-232 -
- Two satellite iridium modems are required, one
connected to the computer and one to the
dataloggers serial port. - Communication is achieved via satellite.
Stylitis-41
Iridium modem
Iridium modem
1412. RF COMMUNICATION
- 7. Via RF modems
-
RS-232
RS-232 -
- Connect one RF Modem to Stylitis-41s serial port
and one to the computers COM port. - Achieve remote connections without a SIM card,
for a limited distance (usually a few kilometers)
between modems.
Radio Modem
Radio Modem
Stylitis-41
1512. COMMUNICATION VIA RF NETWORK
- 8. Measuring network via RF modems
- RS-232
-
RS-232 - RS-232
- Capability of communication with multiple
dataloggers (one at a time), by using an RF modem
for the computer (as a Master) and one for each
datalogger (as Slaves). - Again the distance between the Master modem and
each Slave modem is limited (usually a few
kilometers). - Each datalogger modem is set to have a unique
address. Communicate with one at a time.
Stylitis-41
Radio Modem
Radio Modem
Radio Modem
Stylitis-41
1613. COMMUNICATION VIA REMOTE RF NETWORK
RS-232 RS-232
- 9. Remote measuring network via RF modems
Stylitis-41
- Same method as before, with the difference that
the modem network can be remote, regarding the
computer. - The Master modem can be accessed via the GPRS
network via Symmetrons Sym-o-net modem. - Sym-o-net, as stated in previous chapters can
connect as a client to Diameson Gateway, via a
dynamic IP SIM card. - Again the distance between the Master modem and
each Slave modem is limited (usually a few
kilometers). -
Virtual
COM
Radio Modems
GPRS Network
Internet
Diameson Gateway
Sym-o-net
1718. STYLITIS EXPLORER STARTING UP
- Stylitis Explorer is Stylitis-41s free operating
software. - Start up with Stylitis Explorer, by creating Site
folders and Connections. - Create one unique site folder for each
datalogger. - In each site folder, multiple (different types
of) connections can be created for the logger.
The different connection types correspond to the
communication methods, discussed before. - The connections created are saved as windows
files, which are recognized by Stylitis Explorer
in a folder interface, along with the compressed
and decompressed data files (see Chapter 20), and
setup files, ie logger settings (see next
Chapter) saved in a file. - There is also a user friendly way to manage and
view a list of all the created sites and go to a
specific site with a double-click. View
statistics, such as last connection and download
(manual and automatic). - Refer to the corresponding screen shot in Chapter
22. - After achieving a connection, you can communicate
with the logger. Besides changing logger and
Sym-o-net modem (if used) settings and download
data, you can view some features, and
specifically - View the loggers status Instant parameters,
such as the date and time, the battery voltage,
the current data file being recorded, the
recording time remaining in the buffer and in the
card, etc. - View an Online plot of the selected channels
values. All samples are plotted (every second).
Appropriate units appear on the plot.Refer to
the corresponding screen shot in Chapter 22. - Via the virtual keyboard, navigate in the
loggers menus to view the instant channel values
and the status parameters one by one.
1819. STYLITIS EXPLORER SETUP
- Connect to the datalogger, via Stylitis Explorer,
via one of the connections you created and modify
its setup, ie settings such as the recording
interval (selectable from 1 min to 1 hour) and
the loggers site name. However, the main
settings to be adjusted are the channel settings.
- CHANNEL SETTINGS
- The settings of all channels can be changed in
two ways - Manually. Change settings manually. Manual setup
can be done either via a virtual keyboard, by
navigating in the loggers menus or via the user
friendly Easy Setup (see Chapter 22 for screen
shot) - Select mode. For counter channels select Counter,
Frequency or Events. For analog ones, select
Analog, PT-100 or Vane. - Select type. For counter channels, select TTL,
REED, SIN or 40 (SIN with filter). For Analog
channels A3, A4, enable/ disable the gain (which
is standard, by request). - Type the Slope and Offset parameters.
- Via Stylitis Explorers Sensor Library. Via Easy
Setup again, instead of changing the settings
manually, you can select a specific measurement
and then a specific sensor, related to this
measurement. Optionally, also change the
measuring units. All settings are updated
automatically. - SYM-O-NET SETTINGS
- Sym-o-net is Symmetrons GPRS modem which can
cooperate with Stylitis-41. If you are using it,
adjust its settings via Sym-o-net Programmer, an
add-on software to Stylitis Explorer. The
settings to be adjusted are - Selection of the modems operation, defining the
type of the remote connection, as discussed in
previous chapters GSM data mode, GPRS client
mode (via Diameson server) or GPRS server mode. - SMS cellphone number (optionally). An alarm SMS
is sent if the power supply is found below 11V. - GPRS settings, if GPRS operation is selected. SIM
card provider settings APN, User Name, Password.
Diameson settings IP address and Device
Listening port. - Email settings. Enable or disable encrypted
(according to the password) data emails at least
once a day. Define the SMTP mail server, sender,
recipient and if the SIM card provider requires
authentication, type the email accounts User
Name and Password. - Peripheral Schedule. Define between what hours of
the day the datalogger and Sym-o-nets
DEVICE2and DEVICE3 will be available for remote
communication (and the modem will be turned on).
1920. STYLITIS EXPLORER ACQUISITION AND DOWNLOAD
- After writing the desired setup in the
datalogger, enable data acquisition to start
recording. Data is recorded in compressed form,
in two ways - In the loggers internal 512KB memory (buffer).
Only the current file is stored in the buffer, ie
if you set AcquisitionOFF, the buffer is cleared
and data are lost. - In a removable Compact Flash card (up to 2GB).
The data storage is practically unlimited.
Multiple data files can be stored in the card. A
new file begins when downloading the current file
or disabling and re-enabling the acquisition. - When downloaded, a compressed file is
decompressed into a data file, which can be
viewed via a text editor. Compressed and
decompressed data files are stored in the
loggers site folder, as mentioned in Chapter 18. - Data download can be achieved either manually or
automatically via AutoConnect software (see
Chapter 24). - MANUAL DOWNLOAD
- From the buffer. Download the current file. In
the end, you will be asked if you wish to clear
the buffer and begin a new file or not (the same
file will continue to grow). - From the Compact Flash. There are 3 download
options when you are using a Compact Flash - Download the most recent file. If Acquisition is
ON, this is the current file. In this case, the
current file is firstly closed (the next file
begins) and then downloaded. - Download the cards directory. This way all the
cards files (the last 256 ones) appear with
their number, start date and size. The directory
is also saved in a text file in the site folder. - Download a previous file, by typing their number.
Again, the last 256 files are available. To
download all previous files, retrieve the card
and read it via a card reader.
2021. STYLITIS EXPLORER OFFLINE DATA MANAGEMENT
- After downloading the data files in the site
folder, you can manage them offline. Stylitis
Explorer offers some useful tools for offline
management and presentation - Plot. View the selected channels plot, in up to
3 graph groups. View values at a specific moment
with the channel units.Refer to the
corresponding screen shot in Chapter 23. - Data File Processing. Check the integrity of a
folders files, ie check for missing or duplicate
records or if the interval is the same for all
files. - Statistics. Statistics of the files data can
appear per hour, per day, per month and per year.
Statistics include be the average values of the
data (within the hour, day, month or year), the
max, min or sdv values, or sum of all values.
They are presented via a bar graph or a dot
plot.Refer to the corresponding screen shot in
Chapter 23. - Data Availability. View the percentage of the
available data of a site folder within the years,
in which there are data. For a specific year,
view the corresponding percentage within its
months.Refer to the corresponding screen shot in
Chapter 23. - Convert data file parameters. Apply new Slope and
Offset values in a downloaded file in retrospect
and create a new file. - Export to WindRose/Excel/.CSV/.TAB file. Export a
files data to an Excel, a comma delimited or a
tab delimited file. Especially for wind data
(speed and direction channels), you can export
them to WindRose, the wind analysis software,
add-in to the Microsoft Excel, which is
manufactured by CRES and distributed by
Symmetron.For WindRose, refer to the
corresponding screen shot in Chapter 23.
2122. STYLITIS EXPLORER SCREEN SHOTS (PART 1)
- Site folders and
files interface
Online plot
2223. STYLITIS EXPLORER SCREEN SHOTS (PART 2)
- Data
availability
Data file plot
2324. AUTOCONNECT SOFTWARE
- As stated before, data files can be downloaded
manually, via Stylitis Explorer, via any
connection. - However, data download, along with other actions
as well, can be preformed automatically, in a
regular basis, via the additional free software
AutoConnect. - The datalogger can perform a different action
each weekday - Download Data The current data file, either from
the buffer or from theCompact Flash. There is an
option to clear the buffer in the end or not. - Download Status Instant parameters, such as the
current file, the recording time remaining, etc. - Download Display. Get the instant channel values.
- Update Captum. Captum is a free service to
present real-time and historical data of
Symmetron data loggers on the World Wide Web. -
Captum Plot - The selected action of a weekday can be performed
once a day at a specific selected time, or
infinite connections can be made that weekday
every as many minutes as you wish. - Besides editing the auto connections (like in
Stylitis Explorer) via AutoConnects interface,
you can - View a list of all your automatic connections and
execute one or more manually. - Check each connections latest status, ie if it
succeeded, or failed and why. - View the date and time of last connection and
last successful download for each one.
2425. MAIN APPLICATIONS AND CONCLUSION
- Stylitis-41 could be used in
- Wind energy assessment.
- Solar plant monitoring.
- Weather stations.
- Electrical Measurements.
- and many more
- Summing up, its main advantages are
- Specialized in wind/hydro measurements.
- Variety of sensor types supported, along with
suitable voltage excitation outputs. - Variety of communication methods.
- Free operating and automatic connection software.
25about Symmetron
- Our company was founded in 1989 by experienced
engineers and evolved as a major manufacturer of
dataloggers and supplier of measurement
equipment. Symmetron is certified according to
the ISO9001 quality system and we are proud to
have deployed thousands of measurement systems
worldwide. - Address
- 1, Antikythiron Street
- 153 44 Gerakas
- Greece tel 30-210-6034002fax 30-210-6034003
email info_at_symmetron.grwww.symmetron.gr