Title: STYLITIS-10
1STYLITIS-10
- offers high performance data acquisition and
control in a competitive price
21. MAIN FEATURES
- 8 multi-function channels, which can be used as
- - Measurement inputs 1-2 Counter and
6-7 Analog channels (Ch8 can operate as both)
- 7 digital inputs (the analog ones). - - Control outputs (they change either
manually or as a function of input values). - Sampling once per second.
- Math statistics (Average, Min, Max, Sdv) recorded
per interval (from 1 sec to 1 hour). - Recording in internal 4MB Flash memory.
- Modbus and SDI-12 Interfaces.
- 2 serial communication ports 1 DTE
(COMMUNICATION port) and 1 DCE (PERIPHERAL port).
- Precision current (0.5 mA) and voltage (2.5 V)
excitation outputs.
32. PHYSICAL FORM
- Stylitis-10 features
- Control
- LCD screen and 4-button keyboard local, brief
operation - Total control via our Opton software
- Com Ports 2 serial communication ports 1 DTE
and 1 DCE - ENCLOSURE Plastic ABS, either Desktop or wall
mounted - DIMENSIONS 18 x 10 x 4cm, WEIGHT 200g
- INPUT CONNECTORS Removable screw terminal strips
on front panel
43. COMPATIBLE MEASUREMENTS AND SENSORS
- Input channels supported
- Counters (type SIN or TTL)
- Analog Voltage Inputs (Various Gains, up to
02.5V sensors supported) - Analog Current Inputs (Various Gains, up to
050mA sensors supported) - Digital Bus (MODBUS RTU and SDI12)
- Digital Inputs
- Digital Outputs active low, for control of small
relays, either changed manually or as a function
of input values - Some indicative measurements and related sensors
are - Wind Speed and Direction (Anemometers and Wind
Vanes). - Temperature and Humidity (Thermometers,
Hygrometers and Thermo-hygrometers) - Barometric Pressure (Barometers)
- Solar Radiation (Pyranometers)
- Water Depth and pH (Water Depth and pH sensors)
- Active, Reactive and Apparent Energy and Power
(Single phase and 3-phase Active Energy meters
and 3-phase multifunction meters) - AC and DC Voltage and Current (3-phase
multifunction meters and separate AC and DC
Current and Voltage meters) - and many more
54. COMMUNICATION METHODS AND MODELS
MODEL COMMUNICATION METHODS
Plain Stylitis-10 Locally (RS-232) Via Satellite Via RF Modems
Stylitis-10GSM Via a GSM data call Via GPRS, via a dynamic IP SIM Via GPRS, via a static IP SIM
Stylitis-10Ethernet/ WiFi Via LAN or a static IP internet connection Via a dynamic IP internet connection
65. PLAIN STYLITIS-10
- Locally
- RS-232
- Via Satellite
- RS-232
RS-232 - Via RF Modems.
- RS-232
RS-232
Stylitis-10
Iridium modem
Iridium modem
Stylitis-10
Radio Modem
Radio Modem
Stylitis-10
76. STYLITIS-10 GSM
- Via a GSM data call
-
RS-232 -
- Via GPRS, using a cheap Dynamic IP SIM Card (via
Symmetrons Diameson Server) -
Virtual COM - (Diameson Gateway is Symmetrons software server
connecting all dynamic IP SIM devices) - 3. Via GPRS, using a static IP SIM Card
-
Virtual COM
GSM Network
GSM modem
Stylitis-10GSM
GPRS Network
Diameson Gateway
Internet
Stylitis-10GSM
GPRS Network
Internet
Stylitis-10GSM
87. STYLITIS-10 ETHERNET/WIFI
- Via Ethernet/WiFi (local network or a static IP
internet connection) -
- (An ADSL connection is required only for
connections to the internet) - Via a dynamic IP internet connection (via
Symmetrons Diameson Server) -
Static IP ADSL Router
LAN/ internet
Stylitis-10 Ethernet/WiFi
Dynamic IP ADSL Router
Diameson Gateway
Internet
Stylitis-10 Ethernet/WiFi
98. OPTON SOFTWARE
- Opton is Stylitis-10s free operating software.
Via Opton you can - Create Site folders and Connections. Each
datalogger has its unique folder, while multiple
(different types of) connections can be created
for the logger. The different connection types
correspond to the communication methods,
discussed before. - Modify its Setup Channel parameters (they can be
set manually or automatically, by selecting a
specific sensor from Optons sensor library),
recording interval, GPRS settings, SMS and Email
settings, etc. - Optionally, receive SMSs and Emails. Receive the
daily data file via Email. (Available in both the
GSM and the Ethernet version). Receive SMSs (GSM
version) the average channel values every
interval or every day, an alarm if a control
output changes state, or a PhotoVoltaic (PV)
alarm indicating faulty operation in a solar
plant with multiple inverters. - Alternatively, in dynamic IP GRPS connections
(via Diameson server) and in the Ethernet version
(also via Diameson), instead of SMS, data and
alarms can be sent to a web database, Captum, to
a specific user account and to this accounts
email. Interval data and alarms can be plotted in
Captum, alarms can be shown in a table, while
data statistics are presented in bar graphs per
hour, per day of the month, per day of the week
and per month. - View the loggers status Instant parameters,
such as the current file, the recording time
remaining, etc. - View the instant channel values.
- Enable/ disable data acquisition to create data
files, stored in the 4MB memory. - Download data files, which are stored in the
loggers memory in compressed form. They are
stored and decompressed automatically in the site
folder, to be viewed via a text editor. Download
the recent file (a new file begins) or one or
more previous files at once. - View an Online plot of the channel values. All
samples are plotted (every second). - Manage the downloaded data files offline view
the datachannels plot and statistics (the
sameones presented in Captum), check the
integrity of a folders files (check for missing
or duplicate records or if the interval is the
same for all files).
109. OPTON AND CAPTUM SCREEN SHOTS
- Online
plot
Captum Statistics per weekday
1110. AUTOCONNECT SOFTWARE
- As stated before, data files can be downloaded
manually, via Opton, via any connection. - However, data download, along with other actions
as well, can be preformed automatically, in a
regular basis, via the additional free software
AutoConnect. - The datalogger can perform a different action
each weekday - Download Data All data files missing from the
folder. - Download Status Instant parameters, such as the
current file, the recording time remaining, etc. - Download Current Values. Get the instant channel
values. - The selected action of a weekday can be performed
once a day at a specific selected time, or
infinite connections can be made that weekday
every as many minutes as you wish. - Besides editing the auto connections (like in
Opton) via AutoConnects interface, you can - View a list of all your automatic connections and
execute one or more manually. - Check each connections latest status, ie if it
succeeded, or failed and why. - View the date and time of last connection and
last successful download for each one.
1211. MAIN APPLICATIONS AND CONCLUSION
- Stylitis-10 could be used in
- Electrical Measurements.
- Weather stations.
- Wind energy assessment.
- Solar plant monitoring and faulty operation
detection via alarm. - Remote control of relays.
- Fire prevention networks.
- and many more
- Summing up, its main advantages are
- Combination of analog and digital bus channels in
a competitive price. - Variety of communication methods.
- Free operating and automatic connection software.
- Combination of input channels with control
outputs. - Portability, thanks to its small size.
- Alarm and data SMS and data Emails sent to a
specified recipient.
13about Symmetron
- Our company was founded in 1989 by experienced
engineers and evolved as a major manufacturer of
dataloggers and supplier of measurement
equipment. Symmetron is certified according to
the ISO9001 quality system and we are proud to
have deployed thousands of measurement systems
worldwide. - Address
- 1, Antikythiron Street
- 153 44 Gerakas
- Greece tel 30-210-6034002fax 30-210-6034003