STYLITIS-50
  • Most advanced datalogger for wind energy
    assessment

2
1. MAIN FEATURES
  • 19 channels, and specifically
  • - 9 Counter Channels (types SIN, 40
    (SIN with filter), TTL or REED). - 10
    Analog Channels 2 voltage inputs with no gain
    (05V sensors supported).
    4 voltage inputs with
    gain as well 2 with gain10, 2 with gain200.
    2
    selectable as voltage inputs with no gain or
    current inputs (for 420mA sensors)
    2 only as
    differential inputs PT-100
  • Sampling once per second.
  • Math statistics (Average, Min, Max, Sdv) recorded
    per interval (from 1 min to 1 hour).
  • Recording in internal memory of 512KB (buffer) or
    in Removable Compact Flash Cards (up to 2GB) for
    practically unlimited data storage.
  • Built-in Sym-o-net modem, for GSM/GPRS
    connections and encrypted data emailing.
  • 1 serial communication port (DTE).
  • 1 auxiliary serial port (DCE). Connect an
    additional RS-232 device or sensor, like an
    ultrasonic anemometer, to communicate with it
    remotely, via the same Sym-o-net modem. When
    communicating with the device, communication with
    the datalogger is not possible.
  • Unique sensor supervisor technology. Check the
    power consumption of each sensor separately.
    Shows fault cause without visiting site. Ability
    to isolate faulty sensors.
  • Fixed precision voltage excitation outputs, for
    counter sensor supply 1x2.5V, 9x5V and 2x11V.
  • Pulsed precision excitation outputs, for analog
    sensor supply 1x5V and 1x1mA.

3
2. PHYSICAL FORM
  • Stylitis-50 features
  • Control
  • LCD display and 16-key numeric keyboard local,
    full operation except data download.
  • Total control and more user friendly operation
    via our Stylitis Explorer software.
  • Serial Port/Communication 1 serial communication
    port (DTE), suitable for
  • Local Operation, by connecting it to a PC.
  • Internet/LAN operation, by connecting it to an
    external Serial-to-Ethernet Adaptor.
  • Remote operation is possible via its built-in
    modem (for GSM/ GPRS operation and encrypted data
    emailing). An external modem (of other type, not
    requiring a SIM card) can also be connected to
    the serial port.
  • ENCLOSURE ??65 sealed.
  • DIMENSIONS 27 x 17 x 11 cm, WEIGHT 1,5kg.
  • INPUT CONNECTORS Removable screw terminal strips
    on right side.

4
3. COMPATIBLE MEASUREMENTS AND SENSORS
  • Input channels supported
  • Counters. Type SIN, 40 (SIN with filter), TTL
    or REED
  • Analog Voltage Inputs with no gain. 05V sensors
    supported
  • Analog Voltage Inputs with gain. (gain10 or
    gain200)
  • Analog Current Inputs (for 420mA sensors)
  • Differential PT100 inputs
  • Some indicative measurements and related sensors
    are
  • Wind Speed and Direction (Anemometers and Wind
    Vanes).
  • Temperature and Humidity (Thermometers,
    Hygrometers and Thermo-hygrometers)
  • Barometric Pressure (Barometers)
  • Solar Radiation (Pyranometers)
  • Water Depth and pH (Water Depth and pH sensors)
  • Active Energy (Single phase and 3-phase)
  • AC and DC Voltage and Current (AC and DC Current
    and Voltage meters)
  • and many more

5
4. COMMUNICATION METHODS
  • Communication with Stylitis-50 can be achieved in
    various ways
  • The datalogger can be used
  • On its own, for local and remote (GSM/GPRS)
    operation
  • With a serial-to-Ethernet adaptor, connected to
    its serial port, for LAN/ internet operation
  • With other types of modems (which do not require
    a SIM card), connected to its serial port
  • The communication methods are presented more
    analytically in the next chapters

6
5. LOCAL AND ETHERNET OPERATION
  • Locally

  • RS-232
  • Via Ethernet (local network or the internet)
  • RS-232
  • (An ADSL connection is required only for
    connections to the internet)

Stylitis-50
LAN/ internet
Serial-to-Ethernet
ADSL Router
Stylitis-50
7
6. GSM/GPRS OPERATION
  • Via a GSM data call



  • RS-232
  • Via GPRS, using a cheap Dynamic IP SIM Card (via
    Diameson Server)



  • Virtual COM
  • (Diameson Gateway is Symmetrons software server
    connecting all dynamic IP SIM devices)
  • 3. Via GPRS, using a static IP SIM Card



  • Virtual COM

GSM Network
GSM modem
Stylitis-50
GPRS Network
Diameson Gateway
Internet
Stylitis-50
GPRS Network
Internet
Stylitis-50
8
7. REMOTE OPERATION WITHOUT A SIM CARD
  • Via Satellite
  • RS-232

    RS-232
  • Via RF Modems.
  • RS-232

    RS-232
  • (Access one or more loggers without a SIM card
    within a limited distance-usually a few km)

Iridium modem
Iridium modem
Stylitis-50
Radio Modem
Radio Modem
Stylitis-50
9
8. STYLITIS EXPLORER SOFTWARE
  • Stylitis Explorer is Stylitis-50s free operating
    software. Via Stylitis Explorer you can
  • Create Site folders and Connections. Each
    datalogger has its unique folder, while multiple
    (different types of) connections can be created
    for the logger. The different connection types
    correspond to the communication methods,
    discussed before.
  • Modify its Setup Channel parameters, recording
    interval, GPRS settings, etc.
  • Specifically, channel parameters can be set in 3
    ways manually via a virtual keyboard (same
    buttons and appearance as the real one), manually
    via a more user friendly interface (Easy Setup)
    or automatically (via Easy Setup again), by
    selecting a specific sensor from Stylitis
    Explorers sensor library
  • View the loggers status Instant parameters,
    such as the current file, the recording time
    remaining, etc.
  • View the instant channel values.
  • Enable/ disable data acquisition to create data
    files, stored in the removable Compact Flash card
    (up to 2 GB). Files are not stored in the 512KB
    internal memory (buffer) when acquisition is
    disabled.
  • Download data files, which are stored in the
    Compact Flash card, or the current file of the
    buffer, in compressed form. They are stored and
    decompressed automatically in the site folder, to
    be viewed via a text editor. From the Compact
    Flash you can download the recent file (a new
    file begins), the cards directory (to speculate
    the files size, number, start and end date), or
    a previous file.
  • Adjust the built-in Sym-o-net modem settings, for
    GSM/GPRS connections and encrypted data emails.
  • View an Online plot of the channel values. All
    samples are plotted (every second).
  • Manage the downloaded data files offline.
  • For single data files view the channels plot
    and statistics, apply new Slope and Offset values
    in retrospect
  • For a folders files check the integrity of the
    files (check for missing or duplicate records or
    if the interval is the same for all files) and
    view the data availability within the months and
    years.

10
9. STYLITIS EXPLORER SCREEN SHOTS
  • Online
    plot

    Data file plot

11
10. AUTOCONNECT SOFTWARE
  • As stated before, data files can be downloaded
    manually, via Stylitis Explorer, via any
    connection.
  • However, data download, along with other actions
    as well, can be preformed automatically, in a
    regular basis, via the additional free software
    AutoConnect.
  • The datalogger can perform a different action
    each weekday
  • Download Data The current data file, either from
    the buffer or from theCompact Flash. There is an
    option to clear the buffer in the end or not.
  • Download Status Instant parameters, such as the
    current file, the recording time remaining, etc.
  • Download Display. Get the instant channel values.
  • Update Captum. Captum is a free service to
    present real-time and historical data of
    Symmetron data loggers on the World Wide Web.



  • Captum Plot
  • The selected action of a weekday can be performed
    once a day at a specific selected time, or
    infinite connections can be made that weekday
    every as many minutes as you wish.
  • Besides editing the auto connections (like in
    Stylitis Explorer) via AutoConnects interface,
    you can
  • View a list of all your automatic connections and
    execute one or more manually.
  • Check each connections latest status, ie if it
    succeeded, or failed and why.
  • View the date and time of last connection and
    last successful download for each one.

12
11. MAIN APPLICATIONS AND CONCLUSION
  • Stylitis-50 could be used in
  • Wind energy assessment.
  • Solar plant monitoring.
  • Weather stations.
  • Electrical Measurements.
  • Tank level monitoring
  • and many more
  • Summing up, its main advantages are
  • Specialized in wind measurements.
  • Adequate channel number covering most needs (can
    measure speed/ direction in 9 heights).
  • Variety of sensor types supported, along with
    suitable voltage and current excitation outputs.
  • Unique sensor supervisor technology. Ability to
    isolate faulty sensors, if power consumption is
    high.
  • Variety of communication methods.
  • Free operating and automatic connection software.

13
about Symmetron
  • Our company was founded in 1989 by experienced
    engineers and evolved as a major manufacturer of
    dataloggers and supplier of measurement
    equipment. Symmetron is certified according to
    the ISO9001 quality system and we are proud to
    have deployed thousands of measurement systems
    worldwide.
  • Address
  • 1, Antikythiron Street
  • 153 44 Gerakas
  • Greece tel 30-210-6034002fax 30-210-6034003
    email info_at_symmetron.grwww.symmetron.gr