Title: Planning Department, Permits and Inspections Division


1
Planning Department, Permits and Inspections
Division
  • Building Contractors Luncheon

2
Builders Luncheon
  • Used as communication tool
  • Will invite all builders and contractors that
    conduct business with the city
  • Will discuss code and ordinance issues
  • Will bring up issue of recurring code violations
  • Offer interpretation of codes and ordinances
  • Allow comments from the floor

3
Inspector / Builder Luncheon
  • Questions and Answers

4
Inspector / Builder Luncheon
  • Mayor and Council Members are invited
  • In this picture, Mayor and Building Official
    welcome and introduce new builders in town

5
National Survey Identifies Common Violations
  • Survey date May 2005, 400 Building Officials
    Participated
  • Most common violations in new homes were in wood
    framing.
  • Beam, Studs, Joist sizing, Cutting Notching,
    Fire Blocking
  • Egress Windows, Stairs, Handrails, Guardrails

6
LOCAL SURVEY July 1, 04 through June 30, 05
  • Bldg. Frame inspection 632 Turndowns
  • Bldg. Final Inspections - 330 Turndowns
  • Plbg. Top Out Inspect. - 570 Turndowns
  • Plbg. Final Inspections - 250 Turndowns
  • Elec. Cover Inspection - 376 Turndowns
  • Elec. Final Inspection - 541 Turndowns
  • A/C Cover Inspection - 353 Turndowns
  • A/C Final Inspection - 373 Turndowns

7
Ladder Effect
  • IRC Section 316
  • Ornamental Pattern cannot create a ladder effect
    as shown in this picture.
  • Child can climb and fall.

8
TYPICAL ORNAMENTAL GUARD
9
STEP FLASHING
10
STEP FLASHING APPLICATION
  • ASPHALT ROOFING MANUFACTURERS ASSOCIATION (ARMA)
    RECOMMENDS STEP FLASHING.
  • IRC REQUIRES IT. See Section R905.2.8.4
    Sidewall Flashing

11
(No Transcript)
12
(No Transcript)
13
MANIFOLD PLUMBING SYSTEM
  • APPROVED AND LISTED PLUMBING SYSTEMS ARE
    ACCEPTABLE.
  • MANIFOLD SET-UP MUST NOT INTERFERE WITH THE
    REQUIRED GARAGE / LIVING AREA SEPERATION BY ½
    GYP BOARD AS REQUIRED IN SECTION R309 OF THE IRC.

14
MANIFOLD PLUMBING SYSTEMS
  • IRC CODE REQUIRES ½ GYP BOARD SEPERATION BETWEEN
    GARAGE AND LIVING AREA.
  • SUPPLIED THIN PLASTIC COVER DOES NOT MEET THE
    INTENT OF THE CODE.

15
MANIFOLD PLUMBING SYSTEMS
  • MUST MEET IRC REQUIEMENTS FOR CUTTING AND
    NOTCHING
  • STEEL PLATE OR OTHER MEANS OF SUPPORT AND
    PROTECTION IS REQUIRED

16
GROUNDING
  • NEC SECTION 250-52 REQUIRES ROD TO BE INSTALLED
    AT LEAST 8 IN SOIL AND TOP OF ROD FLUSH WITH
    GROUND LEVEL
  • MANY CASES SERVICES ARE NOT PROPERLY GROUNDED
    WHEN ROD IS NOT IN SOIL THE FULL 8.

17
GROUNDING
  • TESTS CONDUCTED TO DETERMINE IF THERE IS A NEED
    FOR 2 GROUND RODS AS SOME CITIES ARE NOW
    REQUIRING.

18
GROUNDING
  • Spot checks conducted at different locations in
    the city found that at this time we do not need
    two ground rods.
  • Code says we must maintain less than 25 ohms of
    resistance at the ground rod and our tests
    results indicate a variance from a low 4.9 ohms
    to a high 14.3 ohms. All less than 25 Ohms.

19
INSPECTORS TO USE NEXTELS
  • INSPECTORS WILL START USING THEIR NEXTELS TO
    CONTACT CONTRACTORS IN ADVANCE OF ARRIVING AT JOB
    SITE. THOSE WITHOUT DIRECT CONNECT TWO WAY
    RADIO WILL GET A CELL PHONE CALL.