SENA
  • One-Stop Solution in Device Networking

HelloDevice Super series SS100/110/400/800
Dec, 2004
2
Contents
  • Overview
  • Configuration Ways
  • Text-based Interface
  • Web-based Interface
  • Features
  • Operation Modes
  • TCP/UDP Multiple Remote Hosts
  • Security
  • PC Card Support
  • Data Logging
  • Event Handling
  • SNMP
  • Dynamic Domain Name
  • Customization Support
  • Case Studies
  • Door Access Application (Customized)
  • Medical Application (Customized)
  • Bridge Monitoring System

3
Overview (1)
  • Linux-based Open platform (kernel 2.4.2)
  • Supports 1/4/8 serial port (RS232/422/485)
  • 1 PCMCIA slot
  • ATA flash memory, LAN/WLAN, PSTN/CDMA Modem
  • Flexible host mode mode
  • TCP/UDP single/multi-session support
  • Primary/Secondary host support
  • Powerful Security
  • Industry-standard encryption support
  • SSL v3, and TLS v1
  • Encryption algorithm support
  • 3DES, and RC4
  • Flexible customization
  • Linux CLI with development environment
  • Source file add/modify/compile/link in 1MB user
    space
  • Web customization

4
Overview (2)
Connections
Device
Remote Host
Host (SS)
Any device with serial interface
  • RS-232
  • RS-422
  • RS-485
  • LAN
  • Wireless (802.11b)
  • PSTN
  • Mobile (CDMA)

5
Configuration Ways
  • Text-based Interface
  • Web-based Interface

6
Text-based Interface
  • System Console
  • Telnet (port 23) or
  • SSH (port 22)
  • Privileges
  • Admin user can access and edit configuration
    parameters.
  • Root user can have full control on SS via CLI, in
    addition to access and configuration rights.

7
Web-based Interface
Web-based interface using web browsers such as
IE, Netscape and Opera
8
Features
  • Operation Modes
  • TCP/UDP Multiple Remote Hosts
  • Security
  • PC Card Support
  • Data Logging and Event Handling
  • SNMP
  • Dynamic Domain Name
  • Customization Support

9
Operation modes
  • Various operation modes

Remote host
  • TCP/UDP

device
TCP/UDP socket
  • modem emulation

Remote host
DTE
TCP socket
  • Dial-in/out mode

Remote host
modem
TCP socket
DTE
modem
10
TCP/UDP Multicasting
  • Overview
  • Configuration
  • Connection
  • Application Diagram
  • Application Areas

11
Overview
  • SS supports an enhancement transmission method
    "TCP/UDP multicasting", which transmits serial
    device data to multiple hosts simultaneously.
  • Max. 32 hosts (incomingoutgoing) per one port
    allowed.
  • Max. 16 outgoing connections (registered remote
    hosts) per one port allowed
  • Each registered TCP host can have a backup host
  • UDP host mode does not support backup host since
    there is no way to check status of primary remote
    host.
  • Multicasting feature is very useful in
    application areas where user needs to transmit a
    message to several display signboard devices
    simultaneously.

12
Configuration
  • Access the SS web interface
  • Choose Serial port --gt Configuration --gt Port
    --gt Remote host configuration

13
Connection
14
Application Diagram
15
Application Areas
  • Applications which require Multiple data
    transmission include
  • LED Signboard,
  • Electronic Metering,
  • Any customer requiring Multiple data transmission.

16
Security
  • SSL Encryption Overview
  • SSL Encryption Configuration
  • SSL Encryption Connection
  • Other Security Features
  • Application Areas

17
SSL Encryption Overview
  • SSL creates a secure connection between a client
    and a server, over which any amount of data can
    be sent securely.
  • By setting the cryptography method as one of
    SSLv2, SSLv3, SSLv3 rollback to v2 or TLSv1, the
    Super Series can communicate with other device
    supporting SSL/TLS cryptography method in
    encrypted sessions.
  • SSL configuration settings are available only
    when the host mode is set to TCP or Modem
    Emulation mode.
  • SSL works by using a private key to encrypt data
    that's transferred over the SSL connection.

18
SSL Encryption Configuration
  • Access the SS web interface
  • Choose Serial port --gt Configuration --gt Port
    --gt Host mode configuration
  • Choose Serial port --gt Configuration --gt Port
    --gt Cryptography configuration

19
SSL Encryption Connection
  • Run SSL or TLS client application
  • openssl s_client connect 192.168.0.26001 ssl3

20
Other Security Features
  • Serial data encryption
  • 3DES, RC4
  • Static Key encryption
  • Secured Web interface
  • HTTPS
  • IP filtering
  • serial port based IP filtering
  • box based IP filtering
  • Secured file uploading
  • SCP

21
Application Areas
  • Applications which require more secure
    communications include
  • Financial,
  • Retail/POS,
  • Government,
  • Medical, and
  • Any customer requiring enhanced security to
    protect sensitive information.

22
PC Card Support
  • Overview
  • CF Memory card configuration
  • Modem card configuration
  • LAN card configuration
  • WLAN card configuration

23
Overview
  • PC card types that can be added to the SS include
    a serial modem, compact-flash card, wireless LAN
    card, and a network LAN card.

24
CF Memory card configuration
  • Access the SS web interface
  • Choose PC Card --gt Configuration

25
Modem card configuration
  • Access the SS web interface
  • Choose PC Card --gt Configuration

26
LAN card configuration
  • Access the SS web interface
  • Choose PC Card --gt Configuration

27
WLAN card configuration
  • Access the SS web interface
  • Choose PC Card --gt Configuration

28
Data Logging and Event Handling
  • Overview
  • Data Logging Configuration
  • Data Event Handling Configuration
  • Data Event Handling Test

29
Overview
  • The SS can capture all system and port data, and
    save it into a log file. This buffer can be
    viewed from the web, saved to memory, or saved to
    a Flash Card, syslog server or NFS server.
  • System logs track events such as logins,
    authentication failures, system configuration
    changes, and more.
  • Port logs document the data flow through the SS
    serial ports.
  • In addition, the SS can be configured for system
    alerts and notifications. It can send email
    messages when an alarm message is detected in the
    serial port data.
  • The SS uses SMTP for sending email notifications
    and SNMP for trap alerts.

30
Data Logging Configuration
  • Access the SS web interface
  • Choose Serial port --gt Configuration --gt Port
    --gt Port logging

31
Data Event Handling Configuration
  • Access the SS web interface
  • Choose Serial port --gt Configuration --gt Port
    --gt Port logging

32
Data Event Handling Test
  • Event Handling via SNMP browser and SMTP email

33
SNMP
  • Overview
  • Configuration
  • Connection

34
Overview
  • SS supports SNMP that provides status and
    performance of connected serial devices through
    their Ethernet connections.
  • Applications such as NMS or an SNMP browser can
    exchange information with the SS.
  • The SS supports SNMP authentication, Login, and
    Link up traps.
  • The SS supports both versions 1 and 2 of the SNMP
    protocol and delivers the System and Port alerts
    as traps.

35
Configuration
  • Access the SS web interface
  • Choose Network --gt SNMP configuration

36
Connection
  • Authentication, Login, and Link up traps in Kiwi
    SNMP browser

37
Dynamic Domain Name
  • Overview
  • Configuration and Connection

38
Overview
  • Dynamic DNS Protocol enables users to access the
    SS via a domain name for floating IP environments
    such as DSL line and DHCP.
  • To use this service, users must set-up an account
    in Dynamic DNS Network Services and add domain
    name, user name and password on the SS DDNS
    configuration page.
  • Whenever user reboots the SS in floating IP
    environments, it sends updated IP address to
    Dynamic DNS Network Services.

39
Configuration and Connection
  • Access the SS web interface
  • Choose Network --gt Dynamic DNS configuration
  • Access the SS web interface and use domain name
  • For e.g., ismdemo.dyndns.biz

40
Customization Support
  • Overview
  • User Web Customization - HTML pages
  • User Web Customization CGI Java pages
  • Serial Filter Application

41
Overview
  • Web customization options
  • Plain HTML files
  • CGI written in C
  • User application implementation
  • Filter applications in C
  • Other applications in C or shell scripts
  • To quickly develop custom applications that run
    on the HelloDevice Super Series, SDK (Software
    Development Kit) is needed.
  • SS SDK is a 256MB CF card composed of executable
    binaries (including gcc), header files, and
    library files.
  • Executable binaries run on SS (MPC855T Linux)
  • Header files and Library files are compatible
    with SS platform
  • With SS SDK, users can compile their own C/C
    source code to run on SS without installing
    cross-compile utilities on their PC.

42
User Web Customization - HTML pages (1/3)
Preparation
  • If you are using Windows, using SCP (secure copy
    protocol) client tools for Windows will be handy
    for file transfer from/to SS
  • Winscp (GUI)
  • Download _at_ http//winscp.sourceforge.net/eng/
  • Install as other applications
  • Pscp (command line interface)
  • Download pscp.exe _at_ http//www.chiark.greenend.org
    .uk/sgtatham/putty/download.html
  • Copy pscp.exe into C\Windows directory

43
User Web Customization - HTML pages (2/3)
Running User HTML file
  • Prepare index.html file and other related files
    (e.g. index.html and webtest.swf)
  • Just copy the files to SS, /usr2/usrweb directory
    using SCP tools (e.g. winscp) and it will work!

44
User Web Customization - HTML pages (3/3)
Browsing SS User Web Pages
45
User Web Customization CGI Java pages (1/3)
Preparation Recognizing SDK Card
  • After recognition, SDK is mounted on /mnt/flash/
    directory

root_at_192.168.0.15 editconf -------------------
--------------------------------------------------
--------- Welcome to SS-110 configuration page
IP mode DHCP IP
address 192.168.0.15 ---------------------------
--------------------------------------------------
- Select menu 1. Network configuration
ltEntergt Refresh ---gt 3 ---------------------------
--------------------------------------------------
- PC Card configuration -------------------------
--------------------------------------------------
--- Currently configured PC card (none)
Select menu 1. Change card configuration 2.
Stop the card service to disable or remove card
3. Probe a new card ltESCgt Back, ltEntergt
Refresh ---gt 3 Do you want to probe a new pc
card? (y/n) y A new PC card is discovered.
--------------------------------------------------
---------------------------- PC Card
configuration ------------------------------------
------------------------------------------
Currently configured PC card ATA/IDE fixed disk
card Model SanDisk SDP 5/3 0.6 Size 257 MB
File system ext2 ---gt ------------------------
--------------------------------------------------
---- Welcome to SS-110 configuration page
------------------------------------------------
------------------------------ Select menu 1.
Network configuration 6. Exit without
saving 7. Exit and apply changes 8. Exit and
reboot ltEntergt Refresh ---gt 7 Are you sure to
save changes? (y/n) y Saving.. Configuration is
saved successfully Are you sure to apply changes?
(y/n) y Applying........ Configuration is
applied successfully
46
User Web Customization CGI Java pages (2/3)
Compiling and Copying files
  • Make working directory such as /mnt/flash/work
  • Copy cgi source file (e.g. ex.c) into the working
    directory
  • Compile .c file with the option of
    L/mnt/flash/lib (Library path)
  • Copy .cgi binary file to /usr2/cgi-bin/
    directory
  • Copy index.html that has CGI link in it to
    /usr2/usrweb/ directory

47
User Web Customization CGI Java pages (3/3)
Sample CGI Source file and Output
root_at_192.168.0.15/mnt/flash/work cat
ex.c include ltstdio.hgt include
ltstdlib.hgt include ltstring.hgt main(int argc,
int argv) printf("Content-type
text/html\n\n") printf("lthtmlgt")
printf("ltbody bgcolor\"0000C0\"gt")
printf("ltbgtltfont color\"FF0000\"gtThis is a
sample CGI pagelt/fontgtlt/bgt\ n")
printf("lt/bodygt") printf("lt/htmlgt\n")
fflush(stdout) root_at_192.168.0.15/mnt/fla
sh/work gcc -o ex.cgi ex.c -L/mnt/flash/lib root_at_
192.168.0.15/mnt/flash/work cp ex.cgi
/usr2/cgi-bin/ root_at_192.168.0.15/mnt/flash/work
48
Serial Filter Application (1/4)
SS Serial Filter Structure
  • Users just need to write filter application only
    to customize serial port application rather than
    writing whole source code
  • Typical situation for serial application
    customization
  • Add/remove protocol header
  • Periodically check serial device

49
Serial Filter Application (2/4)
Sample file
  • Location /mnt/flash/sample/filter
  • periodic_filter.c
  • Periodic query of the serial device application
    might start from here
  • empty_filter.c
  • Do nothing. Adding/removing header application
    might start from here

50
Serial Filter Application (3/4)
How to
  • Log into the SS (Telnet or SSH)
  • Copy sample file from SDK to working directory
    (e.g. /mnt/flash/work)
  • Compile source file (Be careful with compile
    options)gcc -o myfilter myfilter.c
    -L/mnt/flash/lib lpthread
  • Copy compiled binary to /usr2 directory
  • Specify filter application and arguments using
    configuration web or menu configuration

51
Serial Filter Application (4/4)
Sample Filter and Output
root_at_192.168.0.15/mnt/flash/work cp
/mnt/flash/sample/filter/periodic_filter.c
./myfilter.c root_at_192.168.0.15/mnt/flash/work
gcc -o myfilter myfilter.c -L/mnt/flash/lib
-lpthread root_at_192.168.0.15/mnt/flash/work cp
myfilter /usr2 root_at_192.168.0.15/mnt/flash/work
editconf ---------------------------------------
--------------------------------------- Serial
port configuration - Port 1 --gt Filter
application --------------------------------------
---------------------------------------- Select
menu 1. Filter application path name
/bin/ss.filter 2. Filter application
arguments ltESCgt Back, ltEntergt Refresh ---gt 1
Enter a filter application full path name(ex
/bin/filter) ---gt /usr2/myfilter ----------------
--------------------------------------------------
------------ 1. Filter application path
name /usr2/myfilter 2. Filter application
arguments ltESCgt Back, ltEntergt Refresh ---gt 2
Enter filter application arguments ---gt 'You will
see this msg every 1 sec' 1
52
Case Studies
  • Door Access Application (Customized)
  • Medical Application (Customized)
  • Bridge Monitoring System

53
Door Access Application (Customized)
54
Door Access Application (Customized)
  • Target Device RF-ID Card Reader
  • Application Details
  • Customer has added a user customized filtering
    program that transmits only needed serial-based
    RF's to the management station through the SS110.
  • As a result, the time that is required to process
    visitors door access requests has been
    dramatically minimized.
  • Why SS instead of the PS?
  • Fast response required ? Local protocol parser
    application is required on the SS to reduce the
    network traffic

55
Bridge Monitoring System
System Architecture
56
Bridge Monitoring System
  • Target Device Gage length deformation sensors
    on a Railway Bridge
  • Application Details
  • Long gage length deformation sensors (GPS) that
    are installed throughout a railway bridge to gain
    actionable information from the bridge
  • Why SS110?
  • Powerful logging capability (Syslog server)
  • Wireless LAN thru PCMCIA slot

57
Medical Application
  • Target Device Medical Monitoring Device
  • Application Details
  • Serial based medical devices are connected to
    Ethernet using the SS400/800
  • Medical devices are reset remotely by sending
    serial-break signal thru the SS
  • Serial-break feature is implemented using the
    SS customization feature

58
Contact SENA
  • SENA Technologies, Inc.
  • info_at_sena.com
  • Phone82-2-529-7025
  • Fax 82-2-573-7710
  • Web Address http//www.sena.com
  • 210 Yangjae-dong Seocho-gu
  • Seoul 137-130, South Korea
Write a Comment
User Comments (0)
About PowerShow.com