1
Accreditation for Voting Equipment Testing
Laboratories
  • Gordon Gillerman
  • Standard Services Division Chief
  • gordon.gillerman_at_nist.gov
  • http//www.nist.gov/nvlap

2
What is Accreditation?
  • Accreditation - 3rd partly attestation of
    laboratory competence
  • Standards and Handbooks
  • ISO/IEC 17025 and NVLAP Handbook 150 General
    Requirements
  • NVLAP Handbook 150-22 Voting System Testing
    Laboratory Specific
  • Accreditation is not product certification
  • Laboratories test develop data
  • EAC certifies attestation of voting system
    conformity

3
(No Transcript)
4
NVLAP Accreditation
  • Accreditation process includes
  • Evaluation of laboratory quality documentation
  • on-site visit by a technical assessor(s), with
    expertise in the voting standards, and a quality
    systems lead assessor
  • typically 3 to 4 days
  • Labs are accredited to a core set of set methods
    derived from the voting system standard
  • Objective evidence during assessment is
    documented using checklists developed

5
NVLAP Accreditation
  • Methods of gathering objective evidence include
  • Observations
  • Interviews
  • review of documentation
  • witnessing of testing
  • Nonconformities cited against specific
    requirements in the standard.
  • Labs correct all nonconformities before
    accreditation
  • NVLAP accredited laboratories are recommended by
    NIST for inclusion in the EACs accreditation
    program
  • NVLAP accreditation is renewed annually with
    on-site visits occurring the 1st and 2nd years,
    and every other year thereafter.

6
Program Actions
  • Labs may request to expand their scope of
    accreditation
  • add standards (aka test methods)
  • additional on-site visit may be needed to assess
    labs competency
  • Monitoring visits may occur to verify a labs
    competency for cause
  • Outside entities may bring issues to NVLAPs
    attention.
  • In most cases a monitoring visit would address
    specific concerns
  • If an accredited lab should prove unable to meet
    the accreditation requirements then accreditation
    would be suspended or potentially withdrawn

7
Core Test Methods
  • Federal Election Commission FEC Voting System
    Standard of 2002 (VSS-2002), including the Help
    American Vote Act (HAVA) requirements and the
    Election Assistance Commission (EAC) Voluntary
    Voting System Guidelines of 2005 (VVSG-2005) for
    core test methods involving
  • a. Technical Data Package Review
  • b. Physical Configuration Audit (including
    examination of
  • hardware components for safety,
    usability/accessibility,
  • maintainability/operability of the equipment
    and operational
  • validation against user documentation

8
CORE Test Methods
  • c. Source Code Review
  • d. Witness Build and System Information Testing
  • e. Functional Configuration Audit including the
    operational testing of hardware and software
    components and validation against user
    documentation)
  • f. System Integration Testing (including
    validation of accuracy, reliability, other high
    volume tests, and validation of processes and
    tools provided to support the election
    operation) and
  • g. Telecommunication and Security Testing.

9
(No Transcript)
10
Laboratory Accreditations Role in Voting System
Certification
Voting System Vendor
EAC Certified Voting System List
Certification
Equipment
Accredited Voting System Testing Labs
Voting System Purchaser
Test Results
accreditation
NVLAP and EAC
Write a Comment