Title: LCLS Beam and Detector Simulations


1
LCLS Beam and Detector Simulations
  • ICFA Mini-Workshop on Commissioning of X-FELs
  • April 18-22, 2005

This work was performed under the auspices of
the U.S. Department of Energy by the University
of California, Lawrence Livermore National
Laboratory under contract No. W-7405-Eng-48 and
by Stanford University, Stanford Linear
Accelerator Center under contract No.
DE-AC03-76SF00515 for the LCLS project..
2
Outline
  • Spontaneous Radiation Model
  • Spontaneous and FEL signals in Direct and
    Indirect Imager Diagnostics
  • Spontaneous Reflection in Undulator Vacuum
    Chamber
  • Conclusions

3
Spontaneous Radiation Model
4
Spontaneous Data Chain
  • UCLA Near-Field Calculator
  • 2 Gbyte HDF5
  • HDF5 to Paradox Converter
  • (x,y,E,P) Paradox format, 4 X 1 GByte
  • ReBinner Coarser Energy Bins (159)
  • (x,y,E,P) Paradox format, 350 MByte
  • DB Converter faster to read
  • (E,Px,y) Paradox, 50 MBytes
  • Viewer

5
Spontaneous Fluence at NEH Hutch 1
Te 4.5 GeV Z 243 m Dx 1.0 mm Dy 0.3
mm 1.85 mJ
Te 14.5 GeV Z 243 m Dx 0.3 mm Dy 0.1
mm 18.2 mJ
2
4
6
Energy Slices
Near-Field calculation 88 m from
End-of-Undulator, Sven Richie, UCLA
20 mm
20 mm
Far-Field calculation 400 m from
Center-of-Undulator, Roman Tatchyn, SSRL
0 lt E lt 10 keV
7.6 lt E lt 9.0 keV
10 lt E lt 20 keV
20 lt E lt 27 keV
7
LCLS beam footprint
Expected LCLS beam profile contains FEL and
Spontaneous halo
2-3 mJ FEL
20 mJ Spontaneous
3 mJ High energy core Eg gt 400 keV
At entrance to NEH, FEL tuned to 8261 eV
Fundamental
8
Spontaneous and FEL signals in the Direct Imager
Diagnostic
9
Camera Image Calculator Chain
Spontaneous DB
Photoelectrons in Camera (2.5 x Zeiss SITEC
CCD)
Spontaneous e x FEL
Absorbed in 25 mm LSO
(E,Px,y)
x e
FEL
Transmitted by Material
10
14.5 GeV Spontaneous, NEH H1
All photons
Stops in 25 mm LSO
11
14.5 GeV Spontaneous Direct Imager Signal
Photons
Energy
All photons
Stops in 25 mm LSO
Photoelectrons/Pixel
CCD photoelectron levels lt 150K e-
Full well (16 bit) 327K e- so this is ½ scale on
CCD readout
(X-Ray resolution 300 x 100 mm)
12
14.5 GeV Spontaneous FEL
Photons
Energy
All photons
Stops in 25 mm LSO
Need attenuation of 2.4 x 10-4 for CCD full well
Photoelectrons/Pixel
(X-Ray resolution 300 x 100 mm)
13
Use of 16.9 mm B4C Attenuator
Raw photon spectra of FEL Spontaneous
Spectra of FEL Spontaneous after B4C
Photons/keV
Spectra of photons stopping in LSO
14
Direct Imager Image
14.5 GeV
100 FEL Spontaneous through 16.8 mm B4C into
25 mm LSO
Good FEL signal at ½ CCD Full Scale but increased
background in image
(X-Ray resolution 300 x 100 mm)
15
How faint can FEL be?
(X-Ray resolution 300 x 100 mm)
14.5 GeV
1 FEL Spontaneous directly into 25 mm LSO
0.01 FEL Spontaneous into 25 mm LSO
16
4.5 GeV Spontaneous, NEH H1
All photons
1.852 mJ
Direct Imager Photoelectrons
8 x 1011
Photons / keV
0
Stops in 25 mm LSO 1.205 mJ
Direct Imager Photoelectrons
(X-Ray resolution 1000 x 300 mm)
17
Total Energy Calorimeter Concept
Cooler
CMR Sensor
Sapphire heat sink
CMR W vs T
Si or Be 1x1x.5 mm
Xray Beam
Electrothermal Feedback
Apply constant V Measure I Calculate P
Direction of heat flow
18
Energy deposition in each layer
19
SINDA Cool Down Time Results
Cool Down Time is about 0.6 ms
20
Response to 14.5 GeV Spontaneous
Energy Absorbed in 500um Silicon
21
Response to 14.5 GeV Spontaneous 0.01 FEL
Energy Absorbed in 500um Silicon
22
Spontaneous Monte Carlo Chain
  • Spontaneous DB
  • (E,Px,y) Paradox, 50 Mbytes
  • Inject FEL
  • (E,Px,y) Paradox, 50 Mbytes
  • Cumulative DB
  • (x,y,FE) Paradox, 50 Mbytes
  • Photon MC Generator creates random photons
    according to cumulative distribution
  • (x,y,z,vx,vy,vz,E) of individual photons

23
Spontaneous Monte Carlo Simulation
Photon starting angles generated to give
calculated spontaneous spatial distribution
Photon starting x, y matches electron
distribution, a Gaussian with s 30 mm
Photon starting z is uniform along undulator
(from 0 lt z lt 130 m)
24
Each photon final x, y has its own cumulative
energy distribution
Calculated far-field energy spectrum
Monte Carlo Energy Distribution
25
Simulated spatial distributions agree with
far-field calculation
All Photons
Monte Carlo 465 m from beginning of undulator
Far-Field Calculation 400 m from center of
undulator
26
Simulated spatial distributions agree with
far-field calculation higher orders
27
Monte Carlo Simulation of LCLS
100 FEL Spontaneous
1 FEL Spontaneous
0.1 FEL Spontaneous
28
Indirect Imager Simulation
1 m
2.90068 degrees
Spontaneous e FEL
101 mm
Be/SiC 300 layer pairs 60 Angstrom period Gamma
0.2 On 0.5 mm thick Si 10 cm diameter
29
For Full Power FEL ML allows imager to operate
w/o damage
30
0.1 FEL
31
Low Energy Background Dominates
Egt2.5 keV Cleans up signal !
32
Spontaneous Emission Angle Below Critical Angle
243 m
130 m
60-200 mm
Qmax 0.5 1.8 mRad
Qmin 0.2 0.8 mRad
33
Vacuum Pipe Simulation 14.5 GeV
With pipe
Without pipe
34
Line outs through center
With pipe
Without pipe
35
Reflection at higher orders
UCLA Calculation, without pipe
Monte Carlo, without pipe
Monte Carlo, with pipe
0 lt E lt 10 keV
10 lt E lt 20 keV
20 lt E lt 30 keV
36
Photon Energies gt 400 KeV
Without pipe
With pipe
37
Reflection in pipe at 4.5 GeV
38
Tilted pipe at 14.5 GeV
Pipe parallel to beam
Pipe tilted 19 mR, raised 0.9 mm, and shifted to
the right 0.9 mm
39
Summary
  • Beam modeling codes include direct calculations
    of near-field spontaneous FEL signals and
    Monte-Carlo simulations of scattering
  • Reflection off of undulator vacuum chamber
    seriously distorts the spontaneous radiation
    pattern
  • Direct imager model in progress to specify
    scintillator and attenuator thickness, and CCD
    gain parameters. Similar model for Indirect
    Imager, and Calorimeter.
  • Modeling of other diagnostics is proceeding in
    FY05