SciFi Test Results - PowerPoint PPT Presentation

1 / 13
About This Presentation
Title:

SciFi Test Results

Description:

SciFi Test Results. Zisis Papandreou. SPARRO Group, Regina. Hall D Collaboration Meeting ... 100 MeV /e beam. 20 kHz coincidence rate. Beam was 2x2 cm2 with 2% ... – PowerPoint PPT presentation

Number of Views:40
Avg rating:3.0/5.0
Slides: 14
Provided by: zisispap
Category:
Tags: scifi | results | scifi | test

less

Transcript and Presenter's Notes

Title: SciFi Test Results


1
SciFi Test Results
  • Zisis Papandreou
  • SPARRO Group, Regina
  • Hall D Collaboration Meeting
  • Bloomington, Indiana
  • November 1st, 2001

2
Objectives and Fiber Types
  • Objectives
  • Light collection efficiency (cladding)
  • Scintillation light production (doping)
  • Light attenuation coefficient
  • Timing resolution
  • Fibers Tested
  • Kuraray SCSF-81
  • Single-clad Batch 2000
  • Single-clad Batch 2001
  • Pol.Hi.Tech. 0046
  • Single-clad
  • Double-clad
  • Bicron
  • Prohibitively expensive

3
Experimental Setup
4
Cosmic Rays - Attenuation
Geometric Mean
L/R ADC
Distance from left (cm)
???? 321 cm 259cm
247cm
5
TRIUMF M11 Setup
100 MeV ???/e beam 20 kHz coincidence rate Beam
was 2x2 cm2 with 2 protons
6
Experimental Area
7
Particle ID
300
RF
0
TOF
8
Measurement Groups
  • Group-1 (all fiber bundles)
  • 10 cm length scans, 40-260 cm main runs
  • Group-2 (Pol.Hi.Tech. Multi-clad)
  • Vertical versus Horizontal orientation
    configuration dependence
  • Group-3 (Pol.Hi.Tech. Multi-clad)
  • Beam height scan alignment dependence
  • Group-4 (Pol.Hi.Tech. Multi-clad)
  • Forward/Reverse scan magnetic field dependence
  • Group-5 (both Kuraray bundles)
  • Double thickness thickness dependence

9
Attenuation Length
10
Attenuation Conclusions
  • Kuraray 2000 and 2001 batches were consistent ?
    280cm
  • Pol.Hi.Tech. Multi-clad ? 235cm
  • Pol.Hi.Tech. Single-clad broken
  • No dependence on configuration, beam height,
    magnetic field
  • Numbers lower than KLOE (Kuraray 320cm)

11
Timing Resolution
? Pol.Hi.Tech. Single-clad broken
? Pol.Hi.Tech. Multi-clad
? Kuraray bundles
12
Configuration Dependence
?Vertical
?Horizontal (misaligned)
400ps/650ps 0.62
?Horizontal
13
Next to do
  • Analysis
  • Extract index of refraction
  • Improve timing resolution in software
  • Look at particle ID
  • Compare results with cosmic ray tests
  • Order Kuraray multi-clad fibers and test
  • Repeat cosmic-ray measurements
  • Begin prototype construction
Write a Comment
User Comments (0)