Title: PCI 6th Edition
1PCI 6th Edition
- Building Systems
- (Seismic)
2Presentation Outline
- Building System Loads
- Seismic
- Structural Integrity
- LFRS Walls
- LFRS Frames
- Diaphragms
3Seismic Changes
- Based on new changes to ASCE 7 and ACI 318
- Based current seismic research and observations
4Seismic Changes
- Some of these changes are
- Recognition of jointed panel construction
- Recognition of strong and ductile connections in
precast frames - Recognition and requirements for connections in
precast walls
5Seismic Changes
- Additional changes are
- Modification of drift computation and limiting
drift - Deformation compatibility of elements
- Additional soil type classifications
- Special considerations locations near seismic
faults - Consideration of redundancy and reliability in
strength design requirements
6Seismic Changes
- Design Forces are Based on Risk
- Previous codes based on 10 chance of exceedance
in 50 years - IBC 2000, 2003 codes based on 2 chance of
exceedance in 50 years
7Seismic Risk
- Soil factors
- Other regions of high seismic risk - not just
west coast anymore
8- Practically every precast, prestressed concrete
structure designed under IBC 2000 will require
some consideration of seismic effects.
9Seismic Performance Objectives
- Current design - minor damage for moderate
earthquakes - Accepts major damage for severe earthquakes
- Collapse is prevented of severe events
10Seismic Performance Objectives
- In order to achieve the design objectives, the
current code approach requires details capable of
undergoing large inelastic deformations for
energy dissipation.
11Seismic Design Approach
- Emulation
- No special requirements for low seismic risk
- Chapter 21 requirements for moderate and high
seismic risk - Non-emulative design
- PRESSS
- Acceptance criteria for frames
12Earthquake Loads Equivalent Lateral Force
Method
- Base Shear, V
-
- V CsW
- Where
- Cs - Seismic Response Coefficient
- W - Total Weight
13Equivalent Lateral Force Method Limitations
- This method may not apply to buildings with
irregularities in Seismic Design Categories D, E,
or F
14Earthquake Loads Total Weight, W
- Dead Load of structure plus
- 25 of reduced floor live load in storage areas
- live load in parking structures not included
- Partition load if included in gravity dead
- Total weight of permanent equipment
- 20 of flat roof snow load, pf
- where pf gt 30 psf
15Seismic Response Coefficient, Cs
- Function of
- Spectral response acceleration
- Site soil factors
- Building Period
- Response modification factors
- Importance factor
16Seismic Response Coefficient, Cs
- Step 1 - Determine SS and S1
- Step 2 - Determine site Soil Classification
- Step 3 - Calculate Response Accelerations
- Step 4 - Calculate the 5 Damped Design
Spectral Response Accelerations - Step 5 - Determine the Seismic Design Category
- Step 6 - Determine the Fundamental Period
- Step 7 - Calculate Seismic Response Coefficient
17Step 1 Determine SS and S1
- From IBC Map
- From local building codes
- IBC 2003 CD-ROM
- Based on
- Longitude / Latitude
- Zip Code
18(No Transcript)
19Step 2 Determine Site Soil Classification
- If site soils are not known use Site Class D
- Figure 3.10.7 (a) (page 3-111)
- From soil reports
20Step 3 Calculate Response Accelerations
- SMS FaSS
- SM1 FvS1
-
- Where
- Fa and Fv are site coefficients from Figure
3.10.7 (b) and (c) (page 3-111) - SS spectral accelerations for short periods
- S1 spectral accelerations for 1-second period
- All values based on IBC 2003
21Step 4 Calculate the 5-Damped Design Spectral
Response Accelerations
- SDS (2/3)SMS
- SD1 (2/3)SM1
22Step 5 Determine the Seismic Design Category
- Table 3.2.4.1.
- Sometimes this restricts the type of Seismic
Force Resisting System (SFRS) used (see Figure
3.10.8) (page 3-112)
23Step 6 (Approximate Period) Determine the
Buildings Fundamental Period
- Where
- Ct 0.016 for moment resisting frame systems of
reinforced concrete - 0.020 for other concrete structural systems
- x 0.9 for concrete moment resisting frames
- 0.75 for other concrete structural systems
- hn distance from base to highest level (in
feet)
24Step 6 (Exact Period) Determine the Buildings
Fundamental Period
- Rayleighs formula
- Where
- wi dead load weight at Floor i
- di elastic displacement at Floor i
- Fi lateral force at Floor i
- g acceleration of gravity
- n total number of floors
25Step 7 Determine Seismic Response Coefficient,
Cs
- Lesser of
- Where
- R Response Modification Factor
- Figure 3.10.8 (page 3-112)
- ? Seismic Importance Factor
26Step 7 Determine Cs
- Minimum Value of Cs
- Special Cases In Seismic Design Categories E and
F
Cs 0.044SDS?
27Vertical Distribution of Lateral Force
- Where
- Fx Force per floor
- Cvx Vertical distribution factor
- V Base shear
- k 1 - buildings with a period 0.5 sec
- 2 - buildings with a period gt 2.5 sec
- hi and hx height from base to Level i or x
- wi and wx Level i or x portion of total
gravity load
28Location of Force in Plane
- Accidental Torsion
- calculated by assuming that the center of mass is
located a distance of 5 of the plan dimension
perpendicular to the applied load on either side
of the actual center of mass - Total torsion sum of the actual torsion plus
the accidental torsion
29Seismic Drift Requirements
- Elastic Displacement Amplification
Factor, dx - Stability Coefficient Limits, q
- P-D Effects
30Drift Limits
- Figure 3.10.9 (page 3-113)
31Drift Amplification Factor, dx
- Where
- dx Amplified deflection of Level x
- dxe Deflection of Level x determined from
elastic analysis, includes consideration of
cracking - Cd Deflection amplification factor
- (Figure 3.10.8)
- ? Seismic Importance Factor
32Stability Coefficient, ?
- Where
- Px Total vertical unfactored load including
and above Level x - ? Difference of deflections between levels x
and x-1 - Vx Seismic shear force acting between levels x
and x-1 - hsx Story height below Level x
- Cd Deflection amplification factor
33Stability Coefficient, ?
- The stability coefficient is limited to
-
- Where
- ß ratio of shear demand to shear capacity
between Levels x and x-1
34P-D Effects
- To account for P-? effects, the design story
drift is increased by - (1- ?)-1
-
- If ? lt 0.10, P-? effects may be neglected
35Reliability Factor, ri
- Required in High Seismic Design Categories D, E,
and F - The Earthquake Force is increase by a Reliability
Factor, ri - 1.5 Maximum Required Value
- ri 1.0 for structures in Seismic Design
Categories A, B and C
36Reliability Factor, ri For Moment Frames
- Where, for each level
- Ai floor area
- rmaxi For moment frames, the maximum of the
sum of the shears in any two adjacent columns
divided by the story shear. For columns common to
two bays with moment-resisting connections on
opposite sides, 70 of the shear in that column
may be used in the column shear summary.
37Reliability Factor, ri For Shear Walls
- Where, for each level
- Ai floor area
- rmaxi For shear walls, the maximum value of
the product of the shear in the wall and 10/lw
divided by the story shear.
38Load Combinations
- U 1.4(DF)
- U 1.2(DFT) 1.6(LH)
- U 1.2D 1.6(Lr or S or R) (1.0L or 0.8W)
- U 1.2D 1.6W 1.0L 0.5(Lr or S or R)
- U 1.2D 1.0E f1L 0.2S
- U 0.9D 1.6W 1.6H
- U 0.9D 1.0E 1.6H
- f1 1.0 Parking garages
- 1.0 Live load 100 psf on public assembly
floors - 0.5 All others
39Modification for Vertical Acceleration
- E ?QE 0.2SDSD
- Seismic Load Combinations Become
- U (1.2 0.2SDS)D ?QE f1L 0.2S
- U (0.9 0.2SDS)D ?QE 1.6H
Where QE Horizontal Seismic Force
40Modification for Vertical Acceleration
- E ?QE 0.2SDSD
- Seismic Load Combinations Become
- U (1.2 0.2SDS)D ?QE f1L 0.2S
- U (0.9 0.2SDS)D ?QE 1.6H
41Overstrength Factor, Wo
- Components within the Diaphragm
- Chord ties
- Shear Steel
- Connectors
- ?o 2.0 - Seismic Design Categories C, D, E
and F - ?o 1.0 - Seismic Design Categories A and B
42Special Load Combinations
- U 1.2D fiL Em
- U 0.9D E
-
- Where
- Em WoQE 0.2SDSD
- and
- Wo Overstrength Factor
43Overstrength Factor, Wo
- Connections from Diaphragms to Seismic Force
Resisting System (SFRS) - ?o Seismic Design Categories C and higher
- Figure 3.10.8 (page 3-112)
44Structural Integrity Requirements
- All members must be connected to the Lateral
Force Resisting System (LFRS) - Tension ties must be provided in all directions
- The LFRS is continuous to the foundation
- A diaphragm must be provided with
- Connections between diaphragm elements
- Tension ties around its perimeter
- Perimeter ties provided
- Nominal strength of at least 16 kips
- Within 4 ft of the edge
- Column splices and column base connections must
have a nominal tensile strength not less than
200Ag in pounds
45Structural Integrity Requirements
- Precast vertical panels connected by a minimum of
two connections - Each connection is to have a nominal strength of
10 kips - Precast diaphragm connections to members being
laterally supported must have a nominal tensile
strength not less than 300 lbs per linear ft - Connection details allow volume change strains
- Connection details that rely solely on friction
caused by gravity loads are not to be used
46Lateral Force Resisting Systems (LFRS)
- Rigid frames and shear walls exhibit different
responses to lateral loads
47Influential Factors
- The supporting soil and footings
- The stiffness of the diaphragm
- The stiffness LFRS elements and connections
- Lateral load eccentricity with respect to center
of rigidity of the shear walls or frames
48Shear Wall Systems
- Most common lateral force resisting systems
- Design typically follows principles used for
cast-in-place structures
49International Building Code(IBC) Requirements
- Two categories of shear walls
- Ordinary
- Special
50ACI 318-02 Requirements
- Created an additional intermediate category, but
has assigned no distinct R, ?o and Cd
51ACI 318-02 Wall Definitions
- Defines all shear walls as structural walls
- Three levels of definition
- Ordinary structural (shear) wall
- Intermediate precast structural (shear) wall
- Special precast structural (shear) wall
52Ordinary Structural (Shear) Wall
- Wall complying with the requirements of Chapters
1 through 18 - No special seismic detailing
53Intermediate Precast Structural(Shear) Wall
- Wall complying with all applicable requirements
of Chapters 1 through 18 - Added requirements of Section 21.13
- Ductile connections with steel yielding
- 1.5 factor for non-yielding elements
- IBC imposes restriction that yielding be in the
reinforcing
54Special Precast Structural (Shear) Wall
- Precast wall complying with the requirements of
21.8. - Meeting the requirements for ordinary structural
walls and the requirements of 21.2 - Requires precast walls to be designed and
detailed like cast-in-place walls, emulative
design - Meet the connection requirements of Section 21.13.
55Design Guidelines for Shear Wall Structures
- Evaluation of building function and applicable
precast frame - Preliminary development of shear wall system
- Determination of vertical and lateral loads
56Design Guidelines for Shear Wall Structures
- Preliminary load analysis
- Selection of shear walls
- Final load analysis
- Final shear wall design
- Diaphragm design
57Moment Frame Classifications
- Three Classifications
- Ordinary Moment Frame
- Intermediate Moment Frames
- Special Moment Frames
- Based on Detailing
- Seismic Design Categories
58Ordinary Moment Frames
- Seismic Performance Categories A B
- ACI 318 Chapters 1 to 18
- Response modification factor, R 3
59Intermediate Moment Frames
- Seismic Performance Category C
- ACI 318 only defines intermediate as
cast-in-place - Response modification factor, R 5
60Special Moment Frames
- Seismic Performance Categories D, E, and F
- Yielding will be concentrated in the beam, Strong
column -weak beam behavior - Special Moment frames
- ACI 318 Sections 21.2 through 21.6
- Response modification factor, R 8
61Diaphragms
- A diaphragm is classified as rigid if it can
distribute the horizontal forces to the vertical
lateral load resisting elements in proportion to
their relative stiffness - Long-span applications suggest that many precast
diaphragms may in fact be flexible
62Diaphragm Design
- The distinction between rigid and flexible
diaphragms is important not just for diaphragm
design, but also for the design of the entire
lateral force resisting system.
63Diaphragm Classification
- Flexible diaphragm
- Lateral deflection twice average story drift
- Rigid diaphragm
- Not flexible
- Implies capability to distribute load based on
relative stiffness of LFRS elements
64Steps in the Design Method
- Step 1 - Calculate and compare distribution and
diaphragm forces - Based on rigid diaphragm action
- Based on flexible diaphragm action
- Step 2 - Check of diaphragm deformation with
respect to drift limits - Step 3 - Check attached element drift limits
- Step 4 - Adjustments in vertical element
stiffness and placement to limit drift
65Diaphragm Design Forces
- Based on Wind and Seismic Events
- Wind
- Combined windward and leeward wind pressures
- Act as uniform load on building perimeter
- Distributed to the LFRS based on diaphragm
behavior
66Seismic Diaphragm Design Forces
- Separate calculations from the design of the LFRS
- Diaphragm Design force, FP
- Seismic Design Categories B or C
- Fp 0.2IESDSWp Vpx
- Where
- Vpx represents forces from above levels that
must be transferred through the diaphragm due to
vertical system offsets or changes in stiffness.
67Seismic Diaphragm Design Forces
- Seismic Design Category D
- 0.2IESDSwpxlt Fp lt 0.4IESDSwpx
68Diaphragm Detailing
- Wind and Low Seismic Hazards
- Moderate Seismic Hazards
- Seismic Design Category D - Topped Systems
- High Seismic Hazards - Untopped Systems
69Wind and Low Seismic Hazard
- Seismic Design Category A
- Strength requirements imposed by the applied
forces, No Amplification - Seismic Design Category B
- Requires the design of collector elements
- Does not require forces to be increased by over
strength factor, ?o (Revised from IBC 2000)
70Moderate Seismic Hazard
- Topped and Pretopped Systems
- Seismic Design Category C
- Concrete wall systems have special requirements
IBC 2003 - Diaphragm must include
- special continuous struts or ties between
diaphragm chords for wall anchorage. - use of Sub-Diaphragms, the aspect ratio of is
limited to 2½ to 1
71Moderate Seismic Hazard
- Walls classified as Intermediate Precast Walls
- Collector elements, their connections based on
special load combinations - Need to include overstrength factor
- Ductile connections with wall interface
- The body of the connection must have sufficient
strength to permit development of 1.5fy in the
reinforcing steel
72Seismic Design Category (SDC) D
- Topped Systems
- Untopped Systems
- Not implicitly recognized in ACI 318 - 02
- Section 21.2.1.5
- permits a system to be used if it is shown by
experimental evidence and analysis to be
equivalent in strength and toughness to
comparable monolithic cast-in-place systems
73SDC D Topped Systems
- High strain demand across the joints
- Reinforcing steel needs to be compatible with
this demand - Use of larger wire spacing or bars may be needed
- Mesh in the topping must take the entire shear
across the joint. - Correct lapping to maintain diaphragm integrity
74SDC D Topped Systems
- Specific provisions in ACI 318-02
- Chord steel determined from flexural analysis
- Shear strength based entirely on reinforcement
crossing the joint -
- Vn Acvrnfy
- Where
- Acv thickness of the topping slab
- ?n steel ratio of the reinforcement
75SDC D Topped Systems
- ACI 318-02
- minimum spacing requirement of 10 in
- Diaphragm f -factor vertical element fshear
-factor - May result in f 0.6, based on ACI 318-02
Section 9.3.4
76Questions?