Title: Circuit Board : Electric Gate
1Circuit Board Electric Gate
24V Power supply
White 5-- To red on Gate solenoid Black 6--
To black on gate solenoid
4 8 loop for buzzer
3 red To alert buzzer 9 Green To alert
buzzer
13 and 14 For dry contact activation ( Push
Button)
17 and 18 For serial or voltage pulse
activation, (not to exceed 24V)
Note Placement of Jumpers as per product J1,
J2, J3, J4
2Circuit Board Lights
For Turnstiles and Gate applications
24 Volt power supply
2 and 6 To- red light Black and white wire
4 and 8 loop
3 and 9To -green light. Red and Green wire
13 and 14 for Dry contact activation ( Push
Button)
Note Placement of Jumpers as per product J1,
J2, J3, J4
3Circuit Board Electric Gate with photo eye.
24 Volt power supply
5 Red wire to- gate solenoid. 6 Black wire
to- gate solenoid
10 White wire to- Brown wire of photo eye
11 Black wire to- white wire of photo eye.
12 Red wire to- black and blue wire of Photo eye
13 and 14 for dry contact activation, (If
required)
Note Placement of Jumpers as per product J1,
J2, J3, J4
4Circuit board Waist high Turnstile / High Gate.
24 volt power supply.
5 White wire to- Turnstile Solenoid 6 Black
wire to- Turnstile Solenoid
15 Red wire to- Micro switch 16 Green wire
To- Micro switch
13 and 14 For dry contact activation ( Push
Button )
17 and 18 For Serial or Voltage post, ( not
to exceed 24volts)
Note Placement of Jumpers as per product J1,
J2, J3, J4
5Circuit Board Magnetic Lock Gate.
24 Volt Power supply
5 White wire to Red on Gate Magnet 6 Black
wire to Black on Gate magnet
13 and 14 For dry contact activation ( Push
Button)
17 and 18 for serial or voltage pulse
activation, ( not to exceed 24 V)
Note Placement of Jumpers as per product J1,
J2, J3, J4
6 600lbs Magnetic lock specifications.
CX-91M-06 Installation Instructions 5502
Timberlea Blvd. Mississauga, Ontario L4W
2T7 905-366-3377 Toll Free 877-226-3369 www.camde
ncontrols.com Model Description Features Current
Draw CX-91M-06 Single Basic 480mA _at_ 12V240mA _at_
24V CX-91M-06TDS Single adj. timer, door
position switch bond sensor SHOCK HAZARD.
Care must be taken to keep the power supply and
wiring isolated from ground (earth). Use of an
ohmmeter to test for shorts is recommended prior
to service. A. 12V DC Input Set jumpers for 12V
DC operation. (See diagram below) Connect the
ground (-) lead from a 12V DC power source to
terminal 2.Connect the positive () lead from a
12V DC power source to terminal 1. B. 24V DC
Input Unit is delivered from Factory with single
jumper ON for 24V operation.Connect the ground
(-) lead from a 24V DC power source to terminal
2.Connect the positive () lead from a 24V DC
power source to terminal. C. Contacts Reed
switch dry contacts are rated 0.5 Amp_at_30V DC/AC.
For safe operation, do not exceed this rating.If
you normally require a normally open contact,
connect to the black and green wire of the PCB.If
you normally require a normally closed contact,
connect to the black and red wire of the
PCB. Printed Circuit Board Schematic (shown with
all options) Jumper 12V DC 24V DC Magnet Power
Selector IC 1 Timer Power Supply Reed Switch
(Sensor) White Blue Green Black Red NC NO VR C110
V AC Switch or Solid State Switching Device 12 or
24 VDC CORRECT 110 V AC Switch or Solid State
Switching Device 12 or 24 VDC INCORRECT
Important Power switch should always be wired as
shown below in order to minimize the effect of
residual magnetism. Contact Camden for other
wiring considerations.
7Turnstile Counter
Technical Manual 702084-0001 Series C342 Self
Powered LCD Display HV Input Introduction Your
Veeder-Root brand Series C342 panel instrument is
powered by an internal lithium battery, features
an 8 digit LCD display and is housed in a ultra
compact 1/32 DIN package. An IEC IP65 rated front
panel is suitable for washdown environments. All
models feature signal and remote-reset inputs
capable of accepting the high voltage AC or DC
impulses They can be applied in much the same
manner as electromechanical devices of similar
voltage rating, but have the inherent life and
reliability benefits of modern electronic
design. This product has been configured at the
factory to perform one of the following
functions Count Totalizer, Time Totalizer
(HoursMinutesSeconds), or Time Totalizer
(Hours, 1/100 resolution). Features Available
models include count and time totalization
Unique input circuit accepts 12 to 250 V, AC/DC,
for signal and reset functions Crisp 8 digit
LCD display provides easy to read process
values Compact 1/32 DIN bezel and 60mm behind
the panel depth save panel space Internal
lithium battery provides long life and eliminates
the need for external power IEC IP65 rated
front panel for use in washdown
environments Veeder-Root brand S E T U
P OPERATION Front Panel Reset Used to reset the
Process Value Display, unless disabled through
the keylock input
8(No Transcript)
9ABB Modular Range of Pilot Devices In addition
to traditional operators like Pushbuttons,
Selector switches, Emergency stops and Pilot
lights, ABB also offers a wide range of special
functions such as Machine stops, Toggle switches,
Buzzers, Definite purpose pushbuttons,
Potentiometers and Reset buttons. The pilot
devices have a modern, robust and functional
design and can be used both indoor and outdoor.
On front side the products meet protection degree
IP66 and on terminal side they meet IP20. They
are also approved in accordance with UL Type 1,
3R, 4, 4X, 12 and 13. Operators are available
with bezels in three different alternatives i.e.
black plastic, chrome plastic and metal. Rotation
is prevented by ridges and springs on the
operators. The Contact blocks are provided with
a wiping, cleaning function to secure the contact
function. The contact carriers are color coded to
indicate normally open and normally closed
contacts. For all illuminated products the same
lamp blocks can be used for both filament bulbs
and LEDs. The operators and pilot lights are
fast and easy to install by use of snap-on
solutions. Installation of contact blocks and
actuators can be done separately and pre-wiring
is possible.