Title: PASSER II SOFTWARE
1PASSER II SOFTWARE
2PASSER II
- Progression Analysis and Signal System Evaluation
Routine - Traffic Signal Optimization model
- Texas Transportation Institute (TTI)
- Widely used model for arterial routes
- Component program of AAP
- Arterial Analysis Package
- Pre-Processor
3AAP
- Provides easy access to PASSER II and TRANSYT 7F
- Using one data input scheme
4PASSER II
- A macroscopic, deterministic optimization model
designed to develop maximal bandwidth timing
plans on an arterial highway - Objective function of maximizing bandwidth
efficiency - Ensures good perceived progression timing plans
5- Bandwidth efficiency
- Ratio of thru bandwidth (in both directions)
divided by twice the cycle length
6Inputs
- Traffic volumes, laneage
- Saturation flow rates
- Minimum phase times
- Permitted phase sequences
- Analysis methods
- To evaluate existing conditions
- Enter offsets and splits
- To optimize
- No information is entered
7Outputs
- Three basic types
- Input data report
- Gives all input data in a structured format
- Design recommendations
- Including phase sequences, cycle length, offsets
and splits - measures of effectiveness (MOE) values for
- Bandwidth efficiency
- Bandwidth attainability
- Degree of saturation
- Delay
- Probability of queue clearance and fuel
consumption - Time Space Diagrams
8Using AAP
4
A STREET
9Artery Setup
10Help Options
- F1 for individual help options
- F2 for extended information about the class of
data - F3 for the functional key list
11F1 Help option for Artery Stop Factor
12F2 Help Option for Artery Setup
13F3 Functional Key List
14Artery Data
- Speeds are automatically entered as the values
input in Artery setup - They can be changed individually, if desired
15- Mode can be
- P- pretimed control
- F - actuated control
- S- semi-actuated control
- artery is assumed to be the non-actuated phase
- I no signal control
16Length
From adjacent upstream intersection to the
current intersection
Forward Direction, Eastbound
Second Street
B Street
First Street
Third Street
A Street
1500
1950
1425
If the lengths in the reverse direction are the
same as the forward, press F9 and the lengths
will be automatically input
17Artery Data
- Traffic Volume
- Lanegae
- Right turns are assumed to be shared
- Only enter the number of lanes under the the
right turns if there is an exclusive right turn
lane - Peak Hour Factor
- Saturation Flow
- Minimum Green Times
- Speed
18Traffic Volumes
19Diagram of Network
20(No Transcript)
21Approach Data
- Press F9 to calculate the volume adjustments
- Press escape to accept these values
- Press page down key to enter info for other
intersections
22(No Transcript)
23(No Transcript)
24(No Transcript)
25Timing Plan
26Timing Plan
OR
OR
OR
G
L
T
W
E
N
S
27Timing Plan
OR
F
OR
R
28LT
- Column Subsequence
- 1 leading lefts
- 2 leading thrus
- 3 forward direction leading
- reverse lagging
- 4 reverse direction leading, forward lagging
No. Meaning 0 phase combination not
allowed 1 phase combination allowed, no
overlap 2 phase combination allowed, with overlap
29(No Transcript)
30Example
31Run Instructions
32Run PASSER II
33View PASSER II Output
Then select your file name
34Output Menu
35Best Solution
36A Street and First Street
37(No Transcript)
38Artery Summary
39(No Transcript)
40Time Space Diagram
41Reading PASSER II Output
2 6
4 8
2 6
1 5
3 7
4 8
42Reading PASSER II Output
Draw the phasing diagram assuming EB as the
forward direction for 26, 16, 15, 48, 38,
37
43Example
44(No Transcript)
45First Street and A street
46A Street and B Street
47Length
From adjacent upstream intersection to the
current intersection
Forward Direction, Eastbound
0
800
900
1320
1650
Main Street
1650
1320
900
800
A Street
D Street
C Street
B Street
E Street
If the lengths in the reverse direction are the
same as the forward, press F9 and the lengths
will be automatically input
48Approach Data
49Laneage
Laneage at all intersections NB and SB 1
exclusive left turn lane 1 through and right
turn lane EB and WB 1 exclusive left turn
lane 1 through lane 1 through and right
turn lane
50Phasing