Sensing and Actuation in Miniaturized Systems PRESENTATION - PowerPoint PPT Presentation

About This Presentation
Title:

Sensing and Actuation in Miniaturized Systems PRESENTATION

Description:

The competent cells and the recombinant plasmids are mixed ... effective DNA transformation using competent E. coli cells and plasmid DNA with ... – PowerPoint PPT presentation

Number of Views:13
Avg rating:3.0/5.0
Slides: 12
Provided by: ozNth
Category:

less

Transcript and Presenter's Notes

Title: Sensing and Actuation in Miniaturized Systems PRESENTATION


1
Sensing and Actuation in Miniaturized Systems
PRESENTATION
  • DNA Transformation by
  • Local Heat Shock

9533071 ???
2
Outline
  • Abstract
  • Introduction
  • Design And Fabrication
  • Experimental Procedure
  • Results
  • Conclusions

3
Abstract
  • DNA transformation by local heat shock using a
    MEMS device has been successfully demonstrated
    using an on-chip micro heater and corresponding
    microfluidic system
  • The transformation experiments have been
    conducted and 200 improvement in transformation
    efficiency was showed as compared with control
    tests using conventional methodology

4
Introduction
  • Widely used in genetic engineering and molecular
    biology as an indispensable and key process in
    gene cloning, gene therapy and protein expression
  • Among all the DNA transformation methods,
    electroporation and heat shock are two commonly
    used procedures. Heat shock devices are easy to
    make and biocompatible.
  • Some researchers believe that the abrupt heat
    pulse makes cell membranes more fluid and
    permeable for the foreign DNA to transport into
    cells

5
  1. Bacterial cells, which were treated by chemicals
    such as CaCl2 to make the cell membrane
    permeable
  2. Plasmid DNA, a circular DNA that can replicate
    itself after DNA transformation process

6
Design and Fabrication
  • The competent cells and the recombinant plasmids
    are mixed
  • The mixture is then treated by a brief heat pulse
    at 42? for 90seconds for the transformation
    process
  • A fluidic cap using molded PDMS to construct
    micro chamber and channels and a heating
    substrate with microheaters constructed by
    resistive heaters with electrical insulation
    layer on the top

7
(No Transcript)
8
Experimental Procedure
  • A fine thermocouple (CHAL-0005), was good
    linearity between 0 to 65?, TCR of the heater
    0.0015/? and the coefficient of determination of
    the linear fit is 0.9999

9
  • E. coli stored was thawed on ice and mixed with
    plasmid DNA, which contains both Venus and
    ampicillin resistance gene
  • Compare local heat shock, conventional heat
    shock, and without heat shock

10
Results
  • The micro device achieves 2.62106colonies/µg,
    which is about over 200 better than the
    conventional heat shock result at
    1.13106colonies/µg
  • No transformed cell can be observed without heat
    shock procedure

11
Conclusions
  • A MEMS local heat shock device has been
    successfully designed, fabricated and tested to
    demonstrate effective DNA transformation using
    competent E. coli cells and plasmid DNA with
    embedded Venus gene.
  • The improvement in efficiency is likely coming
    from the effective heating process in the micro
    scale . As such, this MEMS device has potentials
    to be part of lab-on-a-chip systems.
Write a Comment
User Comments (0)
About PowerShow.com