Introduction to NuVAX
Presentation Outline
  • Introduction to NuVAX
  • Benefits
  • Performance
  • NuVAX 1000
  • NuVAX 2000
  • NuVAX 3200
  • Target systems and applications
  • Configuration Form
  • Documenting your configuration
  • Migration plan
  • Test acceptance plan

2
NuVAX Benefits
  • Seamless transition
  • No software migration or re-engineering
  • Lower operating costs
  • Retire old, hard-to-maintain disks and tapes
  • Improve hardware reliability
  • Negligible user re-training
  • Retain existing real-time applications
  • Retain specialized I/O interfaces and expensive
    process control, data acquisition, or telemetry
    equipment

3
NuVAX Performance
  • Increase performance and productivity
  • compared to the 3VUPS of a MicroVAX 3600
  • NuVAX 1000 runs at 18 VUPS
  • NuVAX 2000 runs at 18 VUPS
  • NuVAX 3200 runs at 24 VUPS

4
NuVAX 1000
NuVAX 1000 is a VAX on a Board
  • Replaces VAX processor, memory, disks and tape
    drives in the VAX chassis.
  • Applications are transferred onto NuVAXs hard
    drive and run without modification with VAX
    emulation software.
  • Existing specialized Qbus controllers and
    equipment are supported without any configuration
    changes.

5
NuVAX 1000
NuVAX 1000 replaces VAX CPU, memory, disk and
tapes in your Qbus chassis
6
NuVAX 1000
NuVAX 1000 Layout
Front Panel
Standard Quad Width Qbus Controller
Software Key
On-board CPU
40GB Hard Drive
On-board Memory
7
NuVAX 1000
NuVAX 1000 Front Panel
Status LEDs
Console Port
Ethernet Port for Installation Configuration
VAX Network
8
NuVAX 2000
VAX Replacement System
  • Contains NuVAX 1000 with CPU, memory, disk drive
  • In a modern Qbus chassis with reliable new
    backplane and power supply
  • Retain your existing specialized Qbus
    controllers.
  • Or optionally select new replacement modules from
    Logical
  • DRV11-WA, DR11-W
  • DRV11-J
  • DRQ3B
  • IEQ11

9
NuVAX 2000
NuVAX 2000 replaces VAX CPU, memory, disk and
your Qbus chassis
10
NuVAX 2000
NuVAX 2000 Layout
4 available Quad Qbus slots
NuVAX 1000 with CPU, memory, and disks
New backplane
New power supply
11
NuVAX 3200
NuVAX 3200 is a complete VAX replacement system
  • Replaces VAX chassis, CPU, memory, mass storage,
    and Qbus controller.
  • Your VAX Disk images are transferred onto a
    modern system.
  • QP option modules replace your Qbus controllers.

12
NuVAX 3200
NuVAX 3200 replaces the complete VAX system
13
NuVAX 3200
NuVAX with external Qbus controller support
14
NuVAX 3200
NuVAX 3200 System
5 Slots for Option Modules
Emulation Software with License Key
Serial port for Console
Removable SATA Hard Drive
Rack mount system
15
NuVAX 3200
NuVAX Option Modules
  • DRV11-WA, DR11-W
  • DRV11-J
  • DRQ3B
  • DRPI
  • DHV11, DHU11
  • DELQA, DELUNA
  • IEQ11, IEU11
  • Unibus adapter that supports existing Unibus
    controllers
  • We can design an interface for your specific
    application

16
Target Systems for Replacement
MicroVAX II Shown in BA123 Enclosure
MicroVAX 3500/3600 in H9644 Enclosure with
Embedded BA213
17
Target Application
Application tied to Qbus controllers
  • Military or industrial application
  • Real-time operation
  • Investment in specialized equipment

18
Configuration Form
Use of Configuration Form
  • Document your existing system for migration
    purposes.
  • Document migration plan.
  • Document acceptance and verification process.

19
Configuration Form
Document Existing System
Use pull down menus to select module in each slot
Note device address and vector for each module
List any third party controllers
20
Configuration Form
Migration Plan
List the proposed new equipment
21
Configuration Form
Migration Plan
List QP modules for the NuVAX 3200
22
Configuration Form
Migration Plan
List QP modules and Qbus modules for the NuVAX
3200-BA system with external Qbus modules.
23
Configuration Form
Define a Test Acceptance Plan
The test acceptance plan is a quantifiable means
of knowing that the NuVAX system is fully
functional in your application.
24
In Closing
Thank you for your time. We look forward to
working with you in the future. Please let us
know how we can help you with your system
migration.
Write a Comment
User Comments (0)
About PowerShow.com