Title: Qu es Concerto
1RENAISSANCE ZARAGOZA Report on progress on WP1
WP2 planned activities Lyon 27th April 2009
GEE-UdZ
2Summary (27th/04/2009)
- WP1
- WP1.1
- WP1.2
- WP1.3
- WP1.4
- WP1.5
- WP2
- WP2.1
- WP2.2
- WP2.5
3Activity Type RTD/Innovation
WP1 Research, Technological
and Innovation Development
- W.P 1.1 Energy Policy, Planning, RD
- W.P. 1.2 Definition and Validation of
- Design Standards and Bids
- W.P. 1.3 Wood-fuel supply chains assessment and
organisation - W.P. 1.4 ESCo studies
- W.P. 1.5 Socio-economic research
4Summary (27th/04/2009)
- WP1 Research, Technological and Innovation
Dev - WP1.1 Ready for the final document (ZAR) on
July/September 2009 - WP1.2 Certification tools and analysis of current
normative (coordination with the WP2 for the
experimental verification of S and W points of
these tools. Also to analyze the effect of
changes just coming) - WP1.4 Urbic is ready to complete the ESCo
theoretical analysis. Afterward, we (Urbic and
UoZ) will start the study to propose the creation
of two ESCo as some interesting applications to
real cases. - WP1.5 Year 3 has been lost in what this is
concerned due to ECODES withdrawal and the
process substitution. This and the delay on
experimental data from Digital Monitoring Network
has forced UoZ to evaluate new strategies that
increase the effectiveness to cover the original
objectives in coordination with Lyon and the
CONCERTO PLUS recommendations
5Summary (27th/04/2009)
WP1
- WP1.2 Certification tools and analysis of
current normative - Software development for quick evaluation and
optimization Meteo (ecobuildings) and URSOS
(urban sustainability) (ongoing). - Climate data performed for the first real TRY in
Aragón (finished). - Buildings evaluation with different tools
dynamic calculations with TSBI3 -Bsym-, Energy
Plus, Lyder and Calener, compared with static
calculations made with Meteo and URSUS (ongoing). - Buildings analysis (in Valdespartera and out) to
verify if certification procedures are working or
need some modifications (ongoing). - 12 months program
- Software evaluation and comparison including
certification tools and optimization tools (ß
version) - Conclusions about ecobuildings evaluation
6Summary (27th/04/2009)
WP1 (Urbic)
- WP1.2
- Completed calculations of thermal and
electrical demands of Zaragoza. Raising various
scenarios of uncertainty Energy demand more or
less than expected (depending on level of
bioclimatic design), in order to analyze the
feasibility of energy services in adverse
scenarios (WP1.4). - WP1.3
- Started work on the availability of biomass in
the surroundings of Zaragoza, there arent
significant results at the moment (close to end). - WP1.4
- Once completed the technical-economic analysis
of different options and analyzed the dependency
with adverse scenarios Urbic and UoZ will start
the study of several real cases that could be the
application of the theoretical studies performed
in precedent years what means an extra value
with this new objectives. -
7Summary (27th/04/2009)
WP1
- WP1.5 Alternative procedure to the previous
methodology - We will start with the results o a survey of 1200
people and will use the same test with an
intensive work with selected groups with the
support of blogs and forum in Internet - Selection of 15/18 buildings in Valdespartera and
2/3 in Picarral to develop the following actions - Definition of people interested in the project
- General presentations
- Workshops with small groups (meeting groups)
- Formation/information to interested people
Providing users with saving ideas and tools in
order to get data from them. - Organisation of visits to selected sites
- /
8Summary (27th/04/2009)
- WP2
- WP2.1 Data collecting starting last weeks. Works
in collabo-ration with EVZ and Endesa. Most of
work to be done - WP2.2 Valdespartera buildings evaluation (mostly
done). Coordination with WP1.2 . It will be
almost completed next 12 months. - WP2.3 Data validation to be done next months.
Monitoring will be prepared also for Picarral and
specific buildings. Coordination with Lyon and
CONCERTO PLUS.
9UofZ
WP 1.2 , monday, 27th abril 09
Comparison of methods and results of Z and L
WP 2.1 WP 2.2 WP 2.3
Coordinating the different actions centred on
users and the effect on habits and final energy
consumptions by using the successive series of
measured data
Final set up of probes in Valdespartera and CUS.
We are considering options for Picarral y CP C. D.
Data of houses probes by Telemando local net
Microclimate measures by Telemando local net
Simulations and analysis of buildings ongoing
Thermography analysis and air infiltrations in an
extended number of buildings to find constructive
techniques or elements that can be problematic or
inadequate
To completed data with electricity and gas
information
To analize the energy flows for the Analizar los
flujos energéticos completos de la urbanización
(con extensión a Picarral)
Crossing data with socioeconomic information
gathered from users to comparer efficacy of
saving measures
Development of a series of course materials for
training in different levels and different
professional people colleges, masters,
technician, promoters y administration
Dissemination of the results effect on the
energy consumption and its reduction, about the
changes in the attitude of users and there
habits, about the project R. and its different
elements and about the program CONCERTO
itself. Production of materials for dissemination
Coordinated work with Lyon and CONCERTO PLUS to
compare results and relative efficiencies
10Summary (27th/2008)
WP2
- WP2.2 Building simulation and performance
- Information relative to the constructive elements
of the dwelling blocks of each parcel has been
provided by architects and / or the builders of
the plots to start the simulation and
certification process. - As a first step it is checked that the data are
consistent with those stipulated in the partial
plan. If the constructive elements are changed
these new materials must fulfil to the superior
features of the partial plan.
- As the second step energy building simulation is
made for each building with TSBi3 and EnergyPlus. - We provide recommendations to new buildings in
order to optimize results when actions are
possible. - Certification of buildings using the criteria of
the certification program officer LIDER/CALENER
11Blower Laboratory Tests
- Lab tests have been done previous to a series of
measures performed in Picarral and others to be
done in Valdespartera. - So that we will verify the impact of new
normative for the quality or indoor air. - Also a lab cell has been implemen-ted to check
the thermal transmi-ttance of materials, windows
and constructive elements when this information
is not available.
12(No Transcript)