Integrated Information Technologies Measurement
Solutions for the Gas Industry
Richard Cline Integrated Information
Technologies 10960 Stancliff Road, Houston, TX
77099
2
Integrated InformationTechnologies, Inc. (IIT)
IIT has been providing SCADA and data acquisition
turnkey solutions to oil, gas, and utility
industries for over 17 years.
  • Integrated SCADA and data acquisition solutions
    for
  • Custody Transfer Metering / Check Metering
  • Process Plant / Power Substation Monitoring /
    Control
  • Pressure Monitoring / Water Treatment
  • Gas Measurement Applications
  • Data Logging / Data Concentration / Protocol
    Conversion
  • Instrument Monitoring/Controller Applications
  • Strategic alliances / interfaces
  • EFC, RTU, PLC, AMR equipment manufacturers
  • Field Instrumentation / Transmitter Vendors

3
IIT Products
  • SCADA Systems and Data Acquisition Systems
  • IIT Energy Meter with SwRI Algorithm
  • Packaged for PC or field enclosure
  • IIT Measurement Sentinel
  • Instrument Monitoring / Cross-Checks
  • SwRI Energy Meter Algorithm option
  • Other monitoring application options
  • Packaged for PC or field enclosure

4
Components for Real TimeEnergy Measurement
5
SwRI AlgorithmConceptual Flow Chart
6
Heating Value Uncertainty
7
Energy-Meter (IEM)General Applications
  • Enhancement of Composite and Spot Sampling
    Systems With Immediate Response!
  • Gas Quality Monitoring for Natural Gas Engines
    and Turbines
  • Reduce maintenance costs for Online Gas
    Chromatograph.
  • New Method for Determination of Density/Gravity,
    either in Portable or Permanent.
  • Measurement of Fluid Properties in Gas Production
    and Gathering Networks.
  • Energy Metering for Industrial Users.
  • Detect Phase Changes (Dew-Point)

8
Potential Sites for IEM
  • LDC and Industry purchase points
  • Daily history for check-metering against Supplier
    Btu, SpGrav.
  • Real-time Btu, SpGrav insures that required gas
    quality is maintained.
  • Pipeline Company gas sales/delivery points
  • EFM obtains real time Btu and SpGrav from IEM for
    its flow calculations and for energy billing.
  • Gas Storage Facilities (LNG and Wells)
  • Metering of storage withdrawals
  • Blending Applications

9
IIT Energy Meter Interfaces
  • RS485 or RS232 USM Interface to obtain VOS
  • Daniel
  • Sick Maihak
  • Instromet
  • GE Sensing
  • Sensus Low Pressure Ultrasonic
  • RS485 or RS232 EFM Interface to obtain Pressure,
    Temperature, and (optionally) N2 and CO2
  • MODBUS
  • Mercury ECAT
  • Bristol BSAP

10
Energy Meter Primary Features
  • Calculates Btu and SpGrav at pipeline pressure
    for up to 5 USMs
  • Continuous real-time Btu and SpGrav output for
    control, for BTU check-metering, or for analysis
  • Btu backup source and diagnostic for GC
  • Pass-thru port for RS485 maintenance access to
    USM
  • Polling of live inputs via RS485 and/or RS232
  • MODBUS host software access via RS232 local port
    and via internal modem

11
Energy Meter Primary Features
  • Optional AIs for input pressure, temperature
  • Optional AO for 4-20 mAmp Btu or SpGrav real-time
    control output
  • Meter Reports -instantaneous, hourly, daily
    history
  • Optional Interface to Gas Chromatographs
  • Includes IIT Energy Meter Host Software for local
    or remote access
  • CPak Programmable model pipeline to derive
    estimate of N2,CO2 from knowledge base and
    flowrates
  • Optional compact flash board for offload of
    history

12
Energy Meter SoftwarePrimary Features
  • Win2000 / WinXP Platform
  • Local/remote dial-up to configure IEM and to
    upload history
  • Auto-polling of IEM
  • Import history files from optional IEM Compact
    Flash
  • Export history to other software, e.g. Excel
  • Data review/analysis via spreadsheet and graphic
    trending
  • Download Diluent Reference Table (DRT)
  • Optional embedded SwRI Algorithm and AGA-10 for
    analysis

13
Field Beta TestsAgua Dulce Site
  • Prototype Energy Meter configured using IIT RGC
    data logger platform
  • Beta Tests conducted at El Paso Energy Meter
    Station
  • Data collected from Spring 2004 through December
    2004
  • Initial data identified some metering and GC
    related problems at site showing unexpected
    diagnostic benefits of technology. Subject of
    SwRI paper at AGA in March 2005.
  • Final results validated SwRI target of /- 2 BTU
    accuracy.

14
BTU Comparisonw/ Live CO2, N2 (SwRI)
15
IEM User Interface
16
IEM User Interface
17
IEM Diluent Reference Table
18
IIT Measurement SentinelAudit Measurement
Performance
  • Real time calculation of Btu and SpGrav using
    the SwRI Algorithm
  • Audit and monitor measurement site performance
  • Validate GC Using SwRI Algorithm
  • Monitor/Check Ultrasonic Diagnostic Data
  • Validate Ultrasonic VOS using AGA-10 and GC
    composition
  • Do Phase dew-point/bubble-point calculations
  • Synchronize physical sampling to GC sampling
    and IEM calculation
  • Monitor Inlet Filter condition as function of
    flow rate
  • Monitor key measurement parameters for abnormal
    rate-of change

19
  • Actual Applications
  • using the
  • Stand-alone IIT Energy Meter

20
Energy-Meter Installed and Working
21
Energy Meter Installed and Working
22
Energy Meter Installed and Working
23
BTU Comparison-Fixed CO2,N2Patriot Energy Group
24
SpGrav -Fixed CO2, N2Patriot Energy Group
25
BTU ComparisonEFM CO2,N2 (SCP)
26
SpGrav ComparisonEFM CO2,N2 (SCP)
27
IIT Energy Meter (IEM) with SwRI Algorithm
28
INTEGRATED INFORMATION TECHNOLOGIES
  • 10960 Stancliff Road
  • Houston, TX 77099