Title: Integrated Information Technologies
1Integrated Information Technologies Measurement
Solutions for the Gas Industry
Richard Cline Integrated Information
Technologies 10960 Stancliff Road, Houston, TX
77099
2Integrated InformationTechnologies, Inc. (IIT)
IIT has been providing SCADA and data acquisition
turnkey solutions to oil, gas, and utility
industries for over 17 years.
- Integrated SCADA and data acquisition solutions
for - Custody Transfer Metering / Check Metering
- Process Plant / Power Substation Monitoring /
Control - Pressure Monitoring / Water Treatment
- Gas Measurement Applications
- Data Logging / Data Concentration / Protocol
Conversion - Instrument Monitoring/Controller Applications
- Strategic alliances / interfaces
- EFC, RTU, PLC, AMR equipment manufacturers
- Field Instrumentation / Transmitter Vendors
3IIT Products
- SCADA Systems and Data Acquisition Systems
- IIT Energy Meter with SwRI Algorithm
- Packaged for PC or field enclosure
- IIT Measurement Sentinel
- Instrument Monitoring / Cross-Checks
- SwRI Energy Meter Algorithm option
- Other monitoring application options
- Packaged for PC or field enclosure
4Components for Real TimeEnergy Measurement
5SwRI AlgorithmConceptual Flow Chart
6Heating Value Uncertainty
7Energy-Meter (IEM)General Applications
- Enhancement of Composite and Spot Sampling
Systems With Immediate Response! - Gas Quality Monitoring for Natural Gas Engines
and Turbines - Reduce maintenance costs for Online Gas
Chromatograph. - New Method for Determination of Density/Gravity,
either in Portable or Permanent. - Measurement of Fluid Properties in Gas Production
and Gathering Networks. - Energy Metering for Industrial Users.
- Detect Phase Changes (Dew-Point)
8Potential Sites for IEM
- LDC and Industry purchase points
- Daily history for check-metering against Supplier
Btu, SpGrav. - Real-time Btu, SpGrav insures that required gas
quality is maintained. - Pipeline Company gas sales/delivery points
- EFM obtains real time Btu and SpGrav from IEM for
its flow calculations and for energy billing. - Gas Storage Facilities (LNG and Wells)
- Metering of storage withdrawals
- Blending Applications
9IIT Energy Meter Interfaces
- RS485 or RS232 USM Interface to obtain VOS
- Daniel
- Sick Maihak
- Instromet
- GE Sensing
- Sensus Low Pressure Ultrasonic
- RS485 or RS232 EFM Interface to obtain Pressure,
Temperature, and (optionally) N2 and CO2 - MODBUS
- Mercury ECAT
- Bristol BSAP
10Energy Meter Primary Features
- Calculates Btu and SpGrav at pipeline pressure
for up to 5 USMs - Continuous real-time Btu and SpGrav output for
control, for BTU check-metering, or for analysis - Btu backup source and diagnostic for GC
- Pass-thru port for RS485 maintenance access to
USM - Polling of live inputs via RS485 and/or RS232
- MODBUS host software access via RS232 local port
and via internal modem
11Energy Meter Primary Features
- Optional AIs for input pressure, temperature
- Optional AO for 4-20 mAmp Btu or SpGrav real-time
control output - Meter Reports -instantaneous, hourly, daily
history - Optional Interface to Gas Chromatographs
- Includes IIT Energy Meter Host Software for local
or remote access - CPak Programmable model pipeline to derive
estimate of N2,CO2 from knowledge base and
flowrates - Optional compact flash board for offload of
history
12Energy Meter SoftwarePrimary Features
- Win2000 / WinXP Platform
- Local/remote dial-up to configure IEM and to
upload history - Auto-polling of IEM
- Import history files from optional IEM Compact
Flash - Export history to other software, e.g. Excel
- Data review/analysis via spreadsheet and graphic
trending - Download Diluent Reference Table (DRT)
- Optional embedded SwRI Algorithm and AGA-10 for
analysis
13Field Beta TestsAgua Dulce Site
- Prototype Energy Meter configured using IIT RGC
data logger platform - Beta Tests conducted at El Paso Energy Meter
Station - Data collected from Spring 2004 through December
2004 - Initial data identified some metering and GC
related problems at site showing unexpected
diagnostic benefits of technology. Subject of
SwRI paper at AGA in March 2005. - Final results validated SwRI target of /- 2 BTU
accuracy.
14BTU Comparisonw/ Live CO2, N2 (SwRI)
15IEM User Interface
16IEM User Interface
17IEM Diluent Reference Table
18IIT Measurement SentinelAudit Measurement
Performance
- Real time calculation of Btu and SpGrav using
the SwRI Algorithm - Audit and monitor measurement site performance
- Validate GC Using SwRI Algorithm
- Monitor/Check Ultrasonic Diagnostic Data
- Validate Ultrasonic VOS using AGA-10 and GC
composition - Do Phase dew-point/bubble-point calculations
- Synchronize physical sampling to GC sampling
and IEM calculation - Monitor Inlet Filter condition as function of
flow rate - Monitor key measurement parameters for abnormal
rate-of change
19 - Actual Applications
- using the
- Stand-alone IIT Energy Meter
20Energy-Meter Installed and Working
21Energy Meter Installed and Working
22Energy Meter Installed and Working
23BTU Comparison-Fixed CO2,N2Patriot Energy Group
24SpGrav -Fixed CO2, N2Patriot Energy Group
25BTU ComparisonEFM CO2,N2 (SCP)
26SpGrav ComparisonEFM CO2,N2 (SCP)
27IIT Energy Meter (IEM) with SwRI Algorithm
28INTEGRATED INFORMATION TECHNOLOGIES
- 10960 Stancliff Road
- Houston, TX 77099
- Ph. 281-564-4950
- Fax. 281-564-6710