New look at bioluminescence data - PowerPoint PPT Presentation

1 / 18
About This Presentation
Title:

New look at bioluminescence data

Description:

(CompactFlash) Acquisition principle. Timer, then CPU triggers the development of a sequence ... Configuration file defines the run conditions: Thresholds on ... – PowerPoint PPT presentation

Number of Views:153
Avg rating:3.0/5.0
Slides: 19
Provided by: jeanpierr3
Category:

less

Transcript and Presenter's Notes

Title: New look at bioluminescence data


1
New look at bioluminescence data
  • Line setup
  • Data acquisition
  • Optical background rates _at_ 2000 m
  • Sea currents
  • Correlations
  • Biolum vs. current
  • 2000 m vs. 3000 m

2
Experimental layout
3
Batteries
Functional diagram
Container
Scaler A
CPU
Mem
Scaler B
Discri A
Discri B
4
Acquisition principle
Timer, then CPU triggers the development of a
sequence
5
Counting algorithm
7.8 ms
Time limit?
Read Store
no
N0
End of run
Counter reading done in flight ? no dead time
Count duration integer number of ticks ? very
precise
Dead time between counts ? 1 tick
  • What is computable
  • Average frequency for each count
  • What is not accessible
  • The timestamp of the pulses
  • The shape of the pulse

6
Acquisition principle
Timer, then CPU triggers the development of a
sequence
Everyday starts _at_ 0h and 12h
We got 419 files !
?Base lines
7
Most of the time
But, sometimes
8
Baseline extraction
  • Full distribution to define cuts.
  • Choice 45 lt FA lt 75 kHz

Biased due to tail on the right
9
Baseline for the full sample
? 50 kHz
? 30 kHz
10
  • c2 gt 3
  • rmsA gt .8

Reduced sample
? 217 runs left
11
Burst fraction
Which definition?
Number of peaks ? threshold to be defined
Time fraction above threshold ? to be defined
Sources of continuous background
  • K40 Poisson distribution
  • Bacteria emitting continuously light Poisson
    distribution

? Points in the time stream will fluctuate
according to Poisson law
Lets take as limit mean 3 rms
For counter A ? 75 kHz
12
Current velocity
Measurements performed every 30 mn Single shot
measurement ( not average!)
Some peaks at 10 cm/s Average value
3.26 1.62 cm/s
13
Current direction
Dominance NW and SW
Many turns
14
r days
q heading
Units km
15
Correlation Burst Rate / Current velocity
Clear relation between burst activity and current
velocity
16
Correlation with depth Current directions
  • 2 preferred directions
  • 210
  • 300
  • Especially _at_ 3000 m
  • Correlated ?

17
Correlation with depth Current velocities
Comparison, first
18
Conclusions
Background rates measured over 100 days at 2000
m depth at thresholds of .5 and 1 spe
2 times higher than a previous measurement done
_at_ 3000 m
Correlation of burst rate on current intensity
A lot of interesting current data. Need to be
interpreted by expert!!!!
Write a Comment
User Comments (0)
About PowerShow.com