Title: H. Wieman
1EIC Vertexing for A A
- H. Wieman
- Sept. 19, 2002
- BNL
2Motivation for an inner tracker
- A tool for reducing combinatory background to
measure yields of particles with short decay
times - Works with collections of many events
- Background can be less than 1 per event, but
signal is still less - Does not extract special decays event by event in
the high multiplicity environment of AA - Measure D mesons
3Invariant mass reconstruction of D0s ?k
?(preliminary simulation)
D0
S
B
M (GeV)
Because AA at RHIC produces very high
multiplicity events the vertex detector must be
exceptionally good to reduce B
Number of events required to get a statistically
significant result
41 priority go thin to reduce Background
Shows effects of first layer SI thickness,
includes contribution from 760 ?m beam pipe.
Preliminary GEANT simulation
B
Si thickness reduction 300 ?m ? 50 ?m reduces
beam time by factor 19
Si thickness (?m)
5The options
- ATLAS style hybrid
- Thick 300 ?m Si
- High power 800 ?W/cm2 requires liquid cooling,
more thickness - CCDs
- Very thin
- Power vs speed ?
- Rad soft
- Active Pixel Sensors (APS)
- Very thin
- Rad hard enough
- Slow? But good potential with low power
- New technology with normal uncertainties
6APS Compromises
- Short, does not cover diamond
- Most running not luminosity limited so not an
issue unless run with a very good trigger - Slow, contains multiple events
- Background rejection is pileup tolerant
7False rejection by pileup
- Purpose of vertex detector remove primary
tracks before calculating invariant mass - 40 x design luminosity, 5 ms readout
- 400 hits/cm2
- 1.4 pixels filled
- false rejection 0.5
- 40 X design luminosity, 20 ms readout
- 1500 hits/cm2
- 5.3 pixels filled
- false rejection 2.9
8A Monolithic Active Pixel Sensor for Charged
Particle Tracking and Imaging using Standard VLSI
CMOS TechnologyJ.D. Berst, B.Casadei, G.Claus,
C.Colledani, W.Dulinski, Y.Hu, D.Husson, J.P.Le
Normand, R. Turchetta and J.L.RiesterLEPSI,
StrasbourgG.Deptuch, Y.Gornushkin, S.Higueret,
M.WinterIReS, Strasbourg
- LEPSI - IReS APS
- 20 ?m square pixels
- 4 64X64 arrays
- MIMOSA 1, 0.6 ?m CMOS
- MIMOSA 2, 0.35 ?m CMOS
9All this on a 23 ?m by 23 ?m pixel
Rapid progress toward fast low power readout with
on detector zero suppression
10LBL APS test with 1.5 GeV/c e-beam
17 e RMS per pixel
11LBL APS measured MIP signal
Sums of 25 pixel regions centered on pixels with
ADC ? 7
Same sums with empty frames
Background subtracted APS signal with Bichsel
calculation for 8 mm Si
- Conclusion, signal to noise is good enough to get
good efficiency without excessive false hits - The above analysis is with CDS and leakage
current subtraction
12Active Pixel Sensor (APS)
- 20 ?m square pixels
- 5 chips per slat
- 90 million pixels
- 50 ?m thick chips
- 760 ?m Be beam pipe
5.6 cm
8 cm
13One of 8 Modules
LBNL mechanical concept for an inner vertex
detector for STAR
Aluminum/Kapton flex cable under tension
50 ?m Silicon supported under tension
14(No Transcript)
15END