Title: ZenDropper Introduction (EN)
1ZenDropper
- by ZenTech s. a.
- Author Chris Becker
2Index
- Philosophy of ZenDropper
- Technical Specifications
- Integrated Software
- Working Process
- Components
- Features Benefits
- References
3Philosophie of ZenDropper (1)
- We developed the ZenDropper in order to comfort
the increasing demand to automate processes in
laboratories, this need is based on cost
awareness and the need of reproducibility in
order to comply with Quality Standards - The ZenDropper guarantees a uniform output
quality of its working results ensures by that
high cost efficiency as repetition are obsolete - A working process free form human intervention
allows the operator to dedicate himself to other
tasks
4Philosophie of ZenDropper (2)
Sampling
- The ZenDropper eases a crucial step within the
process of karyotyping the Distribution of the
Cells on the Media
Cells Culture
Cells Prepation
Distribution on media
Banding
Reading
5Technical Specifications
- Power
- requirement 230 or 115 VAC
- 50-60 Hz, 500W
- Dimension 79 x 61 x 61 cm
- Weight 65 kg
- Number of
- Needles 2
- Tube holder
- for samples 8
- Racks 1 rack for 40 slides
- Dispensation time
- for samples 3 min / 5 slides
- Extra washing
- needle solution 2 positions
- Applicable cells blood, bone marrow amniotic
fluid and CVS after culture (specific protocol)
6Components
- ZenDropper includes
- Automate
- 2 needls
- 1 distribution of water and distribution,
mixing, aspiration as well as dispensing of
sample - 2 aspiration of residual water
- 1 rack for 40 slides
- Tube holder of 15 ml tubes
- PC Printer
- Software
- ZToolbox for set up, calibration and maintenance
- ZenDropper Soft for operation
- Options
- Exhaust filter
- External Bar Code Reader
7Integrated Software
- ZToolbox
- faciliates the Calibration of ZenDropper and
manages the Maintenance Routine of the equipmente - ZenDropper Soft
- Allows the input and establishment of the Work
List particulars such as - Name of Patient
- Lab internal ID
- Number of slides
- Starts the session on ZenDropper
-
8Working Process (1)
Operator allocates sample tubes and slide rack
1. Placement
Automate measures electronically volume in each
sample tube
2. Sample Validation
Automate creates water layer on all slides for 1
specimen
3. Water Dispensation
Automate creates homogenous solution, ejects 2 µl
on single slide, creating a crater
4. Pre-dispensation
Automate dispense cells in carnoy solution on
single slide
5. Cell Dispensation
Automate aspirates residual water from the very
slide
6. Water Aspiration
Automate repeats steps 4 6 for the remaining
slides of the same specimen
7. Continuation same Sample
Automate repeats steps 3 6 for the remaining
specimens
8. Conclusion of Session
Operator removes sample tubes and slide rack
9. Clearing
9Working Process (2)
10Working Process (3)
manual
1 Sample
2 Sample
ZenDropper
11Working Process (4)
- Alternatively Dry Method is available, it skips
the Water Layer - Dispenses the cells on dry slide
- Applicable for FISH probes
- Improved cell distribution compared to manual
application
12Features Benefits (Automate)
- The ZenDropper
- Works autonomously
- replaces all manual work
- Chassis consist of Front Cover and Exhaust Filter
(option) - Technicians not exposed to methanol and acetic
acid vapours - Low number repetition
- rapid return on investment
- Creates Work Lists via Software
- traceability in laboratory practices
- Sample data could be customised
- Unifrom appearance of data
- Software stores Work Lists
- Availability of each sessions history
13Features Benefits (Process)
- During the working process
- Water Layer Method creates repeatetly same
environment - No time consume for daily set up
- Dispenses cells more homogeneously than manual
- constant position on all the slides / high
reproducibility - When Time Management System detects missing
sample it stalls the automate - Needle does not pass over the slides
- Washing process of 1 needle after dipensation
process - A-sequential order to patient samples
- Slow vertical motion to avoid contamination
- Avoids cross contamination
14References (users)
- 1 unit at Hospital Trousseau, pubilc hospital,
Paris - France - 2 units at Pasteur Cerba, private laboratory
Paris - France - 2 unit at BIOMNIS, private laboratory, Paris -
France - 1 unit at Genetic Department CHU Liège, state
university, Liège Belgium - 1 unit at University of Milan - Italy
- Installation Base of Basic Equipment
- North America Canda, USA
- Middle East Turkey, UAE
- Europe Italy, France, Spain, Germany,
Switzerland ... - Oceania Korea, Australia
- Latin America Argentina, Brazil, Colombia
15References (comparison)
- ZenDropper Process Validation
- (in routine application)
- Comparative study
- Manual vs. ZenDroper, Study performed by CERBA
Pasteur Paris (Genetic department - more than
12000 samples with ZenDropper) - Contamination
- Protocol cells pellets of 240 patients have been
distributed on routine microscopic slide
alternating male/female patient. - Results
- no chromosome Y on female sample observed and
confirmed by Quinacrin test - Conclusion
- No contamination between patients (with regular
maintenance of ZenDropper hydraulic systems)
16Additional information
- Sample volume
- in tube
- Min. 330 µl
- Max. 4000 µl (to create homogeneity)
- Dispensing / slide 30 µl per slide
- Bar Code Labels must comply with banding and
rinsing process hazard of spoiling / washing
off labels - CVS Chorionic Villus Sampling
- 1- technique dit "directe" réaliser directement
sur le prélèvement sans réel culture cellulaire.
Pour cette technique le zendropper ne peut pas
être utilisé. - 2- Technique dit "culture" réaliser après une
semaine de culture des cellules de Chorionic
villus sampling et à la fin de cette technique le
procédure est exactement identique à celui des
Liquide amniotique dont le Zendropper peut être
utiliser très facilement
- Washing of needles
- After each patient with carnoy solution.
- Carnoy Solution is a fixative (60 ethanol 30
chloroform 10 glacial acetic acid)
composition varies Cerba uses 25 Acetic acid
75 Methanol) - Each day with hypochlorid solution
- Customs Clasification No. 90.18.90.85