Title: CESARE Centro dEconomia Sperimentale A Roma Est
1CESARECentro dEconomia Sperimentale A Roma Est
- Plans for Laboratory
- Info Aula 4.
- John Hey
- August 2007
2Observations
- Aula Info 4 is a strange shape.
- There is room for at most 28 workstations.
- We need to have a control room containing the
server and desks. - It seems to be the case that screens between the
subjects can not descend from the ceiling but
must be integral to the units.
3Outline of Plan
- There will be a Control Room.
- There will be five banks of units (workstations)
3 on one side and 2 on the other. Each bank
will be curved. - There will be two big screens, one at each side,
and two ceiling-mounted projectors. - The decoration of the lab needs to be discussed.
4Control Room
- There will be a control room on the right when
entering. - It will contain shelving and desking and the
server for the network. - It should have a wall the bottom part of which
is wood and the top half one-way glass. - I do not think it can have a door.
5Individual Units
- For each subject we need an individual unit
consisting of a desk and screening. - The desk shape is important.
- The CPU is to be stored under the desk.
- The computer (flat-) screen should fold away into
the surface of the desk when not in use. - The screens are crucial.
6Screens in the units
- Each unit needs two screens one in front of the
subject and the other on the long side of the
desk. - The screens should be light (in weight),
translucent and of an agreeable colour. - The should slide up and down and should be 75 cm
in height almost invisible when down and
screening the subject when up.
7Laboratory general view as is (without
workstations)
entrance
unusable
8Basic unit right hand side of lab
height of desktop 75 cm
Computer stored under desk on long side.
Raisable light translucent (plastic) coloured
screens 85 cm high when lowered show 10 cm
above desktop when raised top is 75 cm above
desktop.
9Basic unit left hand side of lab
height of desktop 75 cm
82 cm (outside) 76 cm (inside)
50 cm
Computer stored under desk on long side.
Raisable light translucent (plastic) coloured
screens 85 cm high when lowered show 10 cm
above desktop when raised top is 75 cm above
desktop.
10Juxtaposition of adjacent units right side
Note that there is no gap between the units
because the shorter side of the units is at an
angle of around 95 degrees.
11Juxtaposition of adjacent units left side
Note that there is no gap between the units
because the shorter side of the units is at an
angle of around 95 degrees.
12Laboratory general view with details of
workstations
shelves
shelves
entrance
control room
unusable
desk and screens for server
new wall half with one way glass
Projector in ceiling
Projector in ceiling
Screen for projector
Screen for projector
13Control room
shelves
shelves
desk and screens for server
Entrance no door?
New wall top half with one-way glass so that
people inside can see out, bottom half opaque.
Server located under desk.
14What is needed
- 32 (we only have room for 28 but we will need the
others later) individually built units we need
a carpenter. 32 chairs? - New screens for the workstations (preferably with
built-in video camera). - A server, two projectors and two screens.
- Software (and wiring) for the local network.
- Wall and furnishing for the Control Room desks,
shelves and chairs. - Painting and decorating.
15CESARECentro dEconomia Sperimentale A Roma Est
- Plans for Laboratory
- Info Aula 4.
- John Hey
- August 2007
16(No Transcript)
17(No Transcript)