Genova Site 2004 Report - PowerPoint PPT Presentation

1 / 7
About This Presentation
Title:

Genova Site 2004 Report

Description:

Genova Site - Report at SQTF. G. Darbo ... Status of Loaded Staves in Genova. Stave 4004 - 18/08/2004 ... The encoder parts will be in genova by mid February. ... – PowerPoint PPT presentation

Number of Views:35
Avg rating:3.0/5.0
Slides: 8
Provided by: Giovann74
Category:

less

Transcript and Presenter's Notes

Title: Genova Site 2004 Report


1
Genova Site - 2004 Report
  • C.Gemme, G. Darbo, V.Kostyukhin INFN / Genova
  • Copy of this talk on the CDS Agenda
  • http//agenda.cern.ch/fullAgenda.php?idaa036145

2
Status of Loaded Staves in Genova
  • Stave 4004 - 18/08/2004Pre-production stave,
    completely characterized, data summary available
    athttp//atlas1.ge.infn.it/pixprod/StaveAssembly/
    20212000014004/SUMMARY/
  • Stave 4028 -27/10/2004Initial production stave
    1, completely characterized. On this stave we
    had a power fail on the chiller that had the
    consequence of over heating 6 modules that were
    powered. Temperature on the modules NTC reached
    8090ºC. All the modules tested again after the
    accident and did not show damages. data summary
    available athttp//atlas1.ge.infn.it/pixprod/Stav
    eAssembly/20212000014028/SUMMARY/
  • Stave 4024 - 22/11/2004Initial production stave
    2, LOAD test performed, Burn-in. STAVE test
    underway. The LOAD test have been performed with
    a new set of analysis cuts to overcome the effect
    of HV bias off in the SURF. Survey has been
    made, but there was large difference in
    temperature (6ºC) between loading and survey
    rooms. Because all screws were left tight there
    is a suspect that this induced a deformation to
    the stave due to the large CTE of the aluminum
    cradle. The module position in Z is 1520 µm,
    while in X there is a larger error that we think
    is partially induced by change of bow due to
    thermal effect. When the STAVE test will be
    finished a new survey will be made.Partially
    filled data summary tableshttp//atlas1.ge.infn.i
    t/pixprod/StaveAssembly/20212000014024/SUMMARY/
  • Stave 4048 - 20/12/2004Initial production stave
    3, stave loaded, now under survey.

3
Robot Upgrade
  • To improve the precision of the loading robot, 3
    additions to the setup are under way
  • Temperature will be monitored by a temperature
    logger with 4 channels. Temperature probes have
    been put in thermal contact with support parts of
    the robot and also air temperature is monitored.
  • A linear encoder from Heidenhain, mod. LS-487C,
    having 5 µm precision, have been ordered. The
    encoder has a travel of 92 cm and will be used to
    monitor and correct the linear Z movement of the
    robot stage. The encoder parts will be in genova
    by mid February.
  • A digital measuring microscope has been bought
    and it will be used to measure the position of
    the modules in the garage position or on stave.
    The microscope is from Keyence, mod.VHX-100 with
    two zoom lens (25175 X and 100100 X). It has 18
    MPixels resolution and calibrated measurements in
    the image plane. Also digital image processing
    are available in the system, like depth of focus
    increase and several options for image enhance.

4
Stave T10ºC, Room T0ºC, Pump Speed 18
By Claudia
4
5
6
8
1
Pump Speed
2
3
4
5
Stave T-20ºC, Room T0ºC, Pump Speed 18
By Claudia
Pump Speed
1
2
3
4
5
6
7
8
6
Stave T0ºC,-10ºC,-20ºC, Room T0ºC, Pump Speed 6
By Claudia
Stave Temp.
T 0ºC
T -10ºC
T -20ºC
7
Electrical Test
  • The electrical test for LOAD and STAVE is
    implemented using 2 SURFs boards. It is planned
    to add other 2 to completely automatize the
    system as soon we will receive them from LBL. The
    movement of the source is controlled under
    ambush.
  • For next stave the test should run in completely
    automatic way.
  • Some new analysis cuts have been defined to
    overcome to the "bias effect" on HV off when a
    module is tested with the SURF.
Write a Comment
User Comments (0)