Transcript and Presenter's Notes

Title: Perspective Program for Commercial New Construction


1
Perspective Program for Commercial New
Construction
  • CNC Small Office
  • RTF July 2007

2
Goal A Prescriptive Program For Selected Simple
Commercial New Construction
  • Whole-building, integrated measure approach where
    possible and effective
  • Deemed or deemed-calculated savings
  • Commonality across the region
  • Training for designers, builders developers

3
Progress
  • CNC Strategy Group
  • Six meetings on regional needs opportunities
  • RTF Subcommittee
  • Small Office Focus
  • Reviewed 21 measures, analyzed 8 in detail
  • Oregon code base, two climates Boise Portland
  • Four HVAC system types considered
  • PSZGas, PSZHP, PVAVElec, PVAVGas
  • Details in DRAFT CNC Prescriptive Concept
    July2007.doc

4
Progress
  • Several iterations on baseline conditions
  • Size, fenestration, HVAC system, schedules
  • Several iterations on measures
  • What is the measure, how to model it in EQuest
  • Incremental cost difficult to acquire

5
Detailed Analysis on 8 Measures
  • Glass
  • Code to U40 SHGC40
  • Code to U35 SHGC35
  • Lighting Power Density
  • Code (1.0 W/sf) to 0.75 W/sf
  • HPT8 T5HO
  • Occupancy sensor lighting in open office
  • Fan power improvement
  • Rooftop economizer Cx
  • Premium HVAC equipment (CEE Tier 2 EERs)

6
Summary of Results to Date
  • Most measures look to be TRC cost-effective
    except
  • CEE Tier 2 equipment
  • Fan power in the VAV systems
  • Rooftop CX in the PSZ systems
  • T5HO lighting option
  • Most kWh savings provided by HPT8 lighting
  • Windows Second biggest electric measure the
    biggest gas measure
  • HVAC measures provide about 1/5 of lighting
    window savings

7
Summary of Results to Date
  • Climate makes little difference in the kWh
    savings estimates
  • Except for windows in the HP systems
  • Climate makes a very modest difference in gas
    savings for the U35 window measure
  • HVAC system type has bigger impact on kWh therm
    savings

8
kWh Savings
9
Therm Savings
10
Cost
11
TRC B/C Ratio by Measure
12
Climate Impact on Windows (kWh)
13
Climate Impact on Windows (therms)
14
CEE Tier 2 Equipment
15
Measures Combined to Packages
  • B/C ratios are between 1.0 and 2.0 for most
    packages
  • High B/C measures compensate for low
  • But not enough savings to cover all the low B/C
    ratio measures
  • Either CEE T2 OR T5HO lighting option
  • See tables in SmallOffice-PC253-alpha.xls

16
Issues
  • CEE Tier 2 HVAC Equip
  • Cost uncertainty Low B/C ratio
  • Will costs come down?
  • Packages
  • Is baseline really code? What is standard
    practice?
  • Window U value and SHGC
  • LPD
  • Other measures
  • Other state baselines

17
Recommendations
  • Plenty of cost-effective savings to proceed
  • Start program design work
  • Package measures into appropriate bundles
  • Develop specifications for measures
  • Analyze other state baselines
  • Analyze other climates
  • Design evaluation