Title: GSM Communication The Future of Alarm Communication
1GSM CommunicationThe Future of Alarm
Communication
2What is GSM?
-
- Global System for Mobile Communications
- Developed in 1990s
- One of the leading digital cellular networks
- ATT network in the U.S.
- Rogers network in Canada
- Most popular standard for mobile phones in the
world. - Approximately 70 of the worlds market
- Open standard with roaming capability
-
3Two communication paths GPRS and SMS
- GPRS
- General Packet Radio Service
- Always On connection
- Typically faster than SMS
- Real-time confirmation
- Higher bandwidth capacity
- Supports downloading
- SMS
- Short Message Service
- Store and forward communication
- Sent via SMS Center
- Less bandwidth capacity
- No downloading support
Both signaling and speech channels are
digital. Higher digital voice quality and text
messaging
4Honeywell GSM Radio Offering
- Uses GPRS for reliable transmission of alarm
signals - Back-up reporting with SMS
- Contact ID or ADEMCO Hi Speed
- Power Supply and battery included
- Panel downloading supported
- 6 HW zone inputs (seven zones)
- Tampered enclosure
- Fault Relay output
Future Proof Design Protects Your Business
5Honeywell i-GSM Radio Offering
- Uses an existing internet connection for reliable
transmission of alarm signals - Back-up reporting with GPRS or SMS
- Contact ID or ADEMCO Hi Speed
- Power Supply and battery included
- Panel downloading supported
- 6 HW zone inputs (seven zones)
- Tampered enclosure
- Fault Relay output
6Honeywell GSMCF/iGSMCF Radio Offering
- GSMCF
- Will replace the 7835CF, 7845CF and 7845CZF but
does not replace the 7720ULF or 7720ULFPLUS. - This device cannot be a stand-alone
communicator, although it can be a primary
communicator if you have another form of
communication. - It is designed to replace one phone line to a
fire panel.
- IGSMCF
- This radio has been ETL approved for primary
commercial fire use. - This radio will replace the 7835CF, 7845CF,
7845CZF, 7720ULF and 7720ULFPLUS. - This device is a stand-alone communicator,
designed to replace both phone lines to a fire
panel.
The GSMCF and IGSMCF both come in a red fire
resistant can and includes an externally mounted
antenna (3dB gain).
7GSM CommunicationInstallation Procedures
8Installation Procedures
- Installation of a GSM radio will consist of a few
steps - Activating the SIM card.
- Finding a suitable mounting location with
adequate signal strength. - Wiring to control panel.
- Programming and Registration
9Activating the SIM Card
- The SIM card on the GSM device you are installing
must be activated prior to completing the
registration process. - You will not have any signal strength indication
on your GSM radio prior to SIM activation. - The SIM card can be activated up to thirty days
prior to registration. - You may set up registration at the time of
activation. - If the radio is not registered to an account
within thirty days, the SIM will be automatically
deactivated by Alarmnet.
10Activating the SIM Card
- There are three ways to activate a SIM card
- Log on to Alarmnet Direct website and enter MAC
ID and CRC information - https//services.alarmnet.com/alarmnetdirect/
- Contact your Central Station
- Call Alarmnet SIM activation at 800-222-6525
- Select option 1 for Technical Support, then press
1 for Alarmnet GSM device activation.
- You must have the MAC ID and CRC to activate the
SIM. - It will take from several minutes to a few hours
to activate the SIM.
11Where can I get the Mac ID and CRC?
12Check Signal Strength
9VAC 15VA
NOTE It is extremely important that you select a
suitable mounting location that allows for
adequate signal strength!!!
13Wiring for ECP and 4204 modes
9VAC 15VA
NOTE AC Power must be applied on 1 and 2.
14Wiring for ECP on a LynxR-i
The LynxR-I series panels provide the primary and
backup power for the GSM radio. Do Not Connect
the 7845GSM internal battery or the GSM power
transformer.
NOTE DC Power is supplied from LynxR-i panel.
15Wiring Zone 1 input to a LynxR trigger output
9VAC 15VA
Program Trigger as V- and enable Lynx Panic
NOTE AC Power must be applied to terminals 1 and
2 on 7845GSM.
16Wiring Zone Input for Bell (or positive voltage)
output
17Zone input using NO/NC contact with EOLR
Supervision
18GSM CommunicationProgramming and Registration
19Programming and Registration
- There are several options to program and register
the GSM radio - Log on to Alarmnet Direct website and enter the
appropriate radio and account information - https//services.alarmnet.com/alarmnetdirect/
- Program and register using the 7720p program
tool. - Contact your Central Station
- Call Alarmnet Registration at 800-222-6525
- Select option 1 for Technical Support, then press
1 for Alarmnet GSM device registration.
You must have an account number (provided by your
Central Station) and be able to provide radio MAC
and CRC to proceed with registration.
20Programming Using the 7720p
You must have AC power on terminals 1 and 2 for
7720p to work.
21Programming Basics Using the 7720p
-
- Plug in 7720P programmer and press Enter key
- Press Enter to accept entries
- Use the up/down arrow keys to scroll through the
programming questions without changing any
values. - Perform a Shift function by pressing Shift key
and then the appropriate key.
Strt Prog Mode? Y/N_
Press Shift Y
22Programming Options
Enter Password
Program 7845? Y/N
Press Shift Y
Create Password? Y/N
23Programming Options
Options ECP Zone Triggers 4204 EMU 2 4204s (Use
the space key to scroll through options)
Device Mode? ECP
Primary City ID? (??)
Acct info provided by your Central Station
Primary CS ID? (??)
Primary Sub ID? (????)
24Programming Options
2ND CS Y/N?
Option to use 2nd CS reporting only available on
High-End panels (polling loop panels)
2ND City ID? (??)
2ND CS ID? (??)
2ND Sub ID? (????)
25Programming Options
Device Address (03)
Enable DW Y/N (N)
High-end Panels Only (polling loop)
If Yes
Direct Wire Address (28)
26Programming Mode
Supervision 24 hours
- Options are
- None
- 24 Hours
- 30 days
- Note This feature does NOT enable a test report
to be sent to the Central Station
Old Alarm Time (10 Minutes)
GSM Flt Time (60 mins)
Flt Rel On Y/N (N)
27Programming Mode
Pwr Loss Rpt (Y/N) (Y)
Disable these reports if installing on the
LynxR-I (ECP)
1-3 hours of loss
Low Bat Rpt (Y/N) (Y)
Tamper Rpt (Y/N) (Y)
28Programming Mode
Zones 6 7 are available in ECP mode
Enable Zn 6 (Y/N) (N)
Zn 6 Trigger Type (V)
Restore Zn 6 (Y/N) (N)
Invert Zn 6 (Y/N) (N)
Delay Zn 6 (secs) (00)
Repeat for zone 7 if required
29Zone Mode
- When the GSM is programmed for zone mode, there
are six input zones available. - The first zone input (TB1, pin 5) can detect a
pulsed signal (reported as zone 1) or a steady
signal (reported as zone 2). - When using zone trigger mode, messages are sent
in ADEMCO high-speed format. -
30Zone Mode Programming Options
- Trip Inputs 1or2 w/Bell out (N)
- Enable this option when wiring zone 1/2 input
(terminal 5) to control panel positive bell
output. - This will help prevent false alarms caused by
supervision voltage on the bell circuit. - This will also prevent the radio from causing
bell circuit faults on the control panel. - Note Enabling this feature will raise the trip
voltage on zones 1, 2, and 3 from 2VDC to
5VDC.
This option should not be enabled with negative
trigger inputs on zones 1, 2, or 3.
31Zone Mode Programming Options
This selects the triggering method for this zone
input. Options are (V), (V-), or (EOLR)
If zone is set for (V), the zone will report an
alarm when voltage input is 2VDC-14VDC. Trigger
levels above 14VDC may damage the unit and
trigger levels below 2VDC may not trigger the
zone. Remember Enabling Trip Inputs w/Bell
out increases minimum trigger requirement for
zones 1, 2, and 3 to 5VDC.
32Zone Mode Programming Options
This selects the triggering method for this zone
input. Options are (V), (V-), or (EOLR)
- If the zone is set to (V-), the negative
triggering voltage must be less than 1.0VDC. - If the zone is set to (EOLR), the zone will
report an alarm when the EOLR is removed from the
zone. - Recommended EOLR is 2K ohms.
33Zone Mode Programming Options
Restore Zn1 Y/N (Y)
This enables the zone to report when it is
restored.
Delay Zn1 (secs) (00)
This option defines any delay in reporting for
this zone input (from 0 to 15 seconds).
This option will disable this zone from reporting
unless the conditional zone is triggered. (The
conditional zone is zone 7 when radio is in zone
mode.)
Rpt Zn1 ONLY if Armed (N)
34Zone Mode Programming Options
This option inverts the alarm and normal states
of the zone trigger.
Invert Zn2 Y/N (N)
This option is enabled only when radio is
connected to a Lynx, LynxR, or LynxR-EN. This
enables a silent panic alarm to be sent when a
single pulse is detected on zone 1.
Lynx Panic Y/N (N)
357845I-GSM Programming Options
- Basically the same as the previously discussed
GSM flt time. In the event there is loss of
contact with the network over the Ethernet
connection, enter the time delay before the
7845i-GSM notifies the Central Station of the
problem. - IP failure will always be reported as Primary
Communication Path Failure
IP Flt Time (60 mins)
- Programming options are Neither Fault or
Both IP and GSM Faults. - If Both IP and GSM Faults is selected, the
device will notify the control panel (via ECP bus
or GSM fault relay) if both communication paths
fail.
Notify Panel Of (Neither Fault)_
367845I-GSM Programming Options
- If enabled, all messages (including AlarmNet
network supervisory messages) are sent over GSM
network in the event of an internet failure. - If disabled, all messages (except AlarmNet
network supervisory messages) are sent over GSM
network in the event of an internet failure.
GSM Rollover Y/N (Y)_
- If enabled, the 7845i-GSM sends a supervision
ping over the GSM network once a day to verify
backup communication path. - A secondary communication path loss message is
generated if the message is not successfully
delivered.
GSM 24Hr Tst Y/N (N)_
377845I-GSM Programming Options
Use DHCP Y/N (Y)_
DHCP dynamically allocates the IP addresses
(recommended). If you select No, then you must
program the following fixed (static) IP addresses
NIC IP Address 255.255.255.255_
Gateway IP Addr 255.255.255.255_
Subnet Mask 255.255.255.255_
DNS Server IP Addr 255.255.255.255_
387845I-GSM Programming Options
Enable Pwr Save (Y)_
For 24 UL battery backup requirement, this
feature must be enabled, or the unit must be
powered by an appropriate UL listed UPS.
What does it do?
If the feature is enabled, the communicators NIC
card will power down and will power up every 20
seconds to send a test ping (to test internet
path) then power down again. The NIC will also
power up anytime the unit needs to transmit
information over the internet. If connectivity
problems occur with certain routers or switches,
disable this option.
39GSM CommunicationRegistering the GSM New and
Replacement
40New Registration (Radio on New Account)
After exiting programming mode on the 7720p, you
may register the radio by hitting the Shift key,
then the up arrow.
Shift
Registering
Registration Success
41Replacement Registration
- When registering a replacement radio on an active
account, a pin number must be entered. After
exiting programming mode, select the down arrow
key. You will be prompted to enter a pin. -
- Enter PIN and hit the Enter key to proceed with
registration. - If replacing a C radio, enter the last four
digits of the min number. - If replacing a GSM with another GSM, a PIN must
be generated by your Central Station.
Enter PIN
Registering
Registration SUCCESS
42GSM CommunicationProgrammerless
RegistrationUsing Alarmnet Direct
43Programmerless Registration
- Preliminary Steps Required Before Registration
- Before registering, you must have the following
information available - CITY number
- CS number
- RADIO SUBSCRIBER number
- DEVICE MODE
- Daily or Monthly Supervision
- MAC Address from 7845GSM Radio
- MAC CRC number from the 7845GSM Radio
- City number, CS number, and Radio Subscriber
number is assigned by your Central Station
44Programmerless Registration
- Steps Required to Enter Data
- Log into AlarmNet Direct using your user name and
password. https//services.alarmnet.com/AlarmNetDi
rect - To program a radio on a NEW account, select
Program New Device GSM/I - To replace a C radio with a GSM, select
Replace C Device - To replace a GSM with another GSM, select
Replace Other Device
45Programmerless Registration
- Enter the radios information
- CITY number
- CS number
- SUBSCRIBER number
- Supervision Rate
- MAC number
- CRC number
- Confirm the Device Mode, and if using ECP with
device address 03 click Done.
46Programmerless Registration
Enter 10 digit MIN number from old C Radio
47Programmerless Registration
Enter PIN number generated by your Central Station
48Programmerless Registration
- Important Note About
- Programmerless Replacements!
- The PIN is only transferred to the 7845GSM device
on the first data transfer attempt. - If your device fails to register, take the
following steps using AlarmNet Direct. - Delete the account from Show Programmed
Devices. - Add the account back using Replace C or
Replace Other Device. - From the Show Programmed Devices page, execute
the SEND DATA command and get confirmation of the
data transfer by refreshing the page. - After current date and time are showing in the
Transferred column, execute the Register
command. - Following these steps will ensure the PIN is
transferred to the device. Remember, If the
device fails to register the first time, the PIN
will be reset to FFFF and will not be accepted by
the AlarmNet servers.
49Programmerless Registration
- Selecting Done sets programming to default
values, which is ECP Mode, Device Address 03. - If the installation requires you to change any
programming option from the default value, select
Advanced Programming.
50Programmerless Registration
Screenshot of Advanced Programming screen
51Programmerless Registration
Screenshot of Advanced Programming screen
52Programmerless Registration
Screenshot of Advanced Programming screen
53Programmerless Registration
54Programmerless Registration
- On site click the Tamper Switch 3 times. The
green (status) and yellow (message) LEDs on the
top left should start flashing together.
55GSM CommunicationIP Downloading
56IP Downloading Support
Panels that can be downloaded via GSM
57IP Downloading Support
Panels that can be downloaded via GSM
58Vista-20P and LynxR-i
- The Vista-20P and LynxR-I communicates with the
7845GSM over the ECP (keypad) bus. - To setup the control panel, do the following
- Connect the 7845GSM module to the control panels
ECP (keypad) terminals as you would a keypad. - Enable the 7845GSM as a Long Range Radio in the
control panel to enable alarm reporting and
module supervision. - Vista - 29 1
- LynxR-I - 55 1
- Program the 7845GSM and set the ECP address to 3.
- Register the 7845GSM with AlarmNet. The module
must be registered before downloading or alarm
reporting can take place.
59Vista-128/250BP and Vista-128/250FBP
- To set up the control panel, do the following
- Connect the 7845GSM module to the control panels
ECP (keypad) terminals as you would a keypad. - Program the 7845GSM as required using the 7720P
programmer. (To do this, temporarily disconnect
the RJ11 from the 7845GSM and plug in the
programmer). Remember to program - Question 13 (ANI ECP Address) with the same
address programmed in Step 4. Two additional
programming questions have been added for direct
wire downloading over IP - Question 14 (Enable DW) to enable direct wire
downloading and - Question 15 (Direct Wire Address), to tell the
7845GSM what keypad address the 7845GSM is going
to use for direct wire downloading (same address
as entered in Step 5). - Connect the trigger cable between the control
panel trigger connector and the 7845GSM (RJ11
connection). - Enable an address for the 7845GSM as a Long Range
Radio (LRR) in the control panels Device
Programming Mode (93). This enables the 7845GSM
on the control panel.
60Vista-128/250BP and Vista-128/250FBP
- Enable a second address for the 7845GSM as a
keypad in the control panels Device Programming
Mode (93). This enables the control panel to
perform downloading over IP. Do not connect an
actual keypad or any other device at this
address. - Register the 7845GSM with AlarmNet. The module
must be registered before downloading or alarm
reporting can take place.
61Direct Wire Connections
62GSM CommunicationDiagnostics
63Exterior L.E.D. Status
64Mode and Status Indicator Switch
LED 4 not used on 7845GSM
65Mode and Status Indicator Switch
Remember LED 4 not used on 7845GSM
Connected To Web
667845i-GSM Network Connectivity Display
677845GSM ECP Keypad Display Status Codes
Note You can only display Status Codes on an
alpha keypad.
687845i-GSM ECP Keypad Display Status Codes
Note You can only display Status Codes on an
alpha keypad.
697845GSM Central Station Messages
707845i-GSM Central Station Messages
71http//www.security.honeywell.com/hsce/ and click
on MyWebTech User name honeywell Password
support99 Honeywell Security support e-mail
mywebtech_at_honeywell.com