Working Principle of the Heat Recovery System
SOLAR HEAT
Hot Water Systems
The ecogen HRS can be installed anywhere where
hot water is needed. The HRS water tank is
linked to the A/C system which comprises a
condenser, expansion valve, evaporator and
compressor. The whole system can be explained by
using two loops.
COOLED AIR
4
5
The refrigerant gas then passes through the
condenser where it is further condensed into
liquid.
The Refrigerant is super-cooled returned to the
evaporating unit to complete the refrigerant loop.
6
1
HEATS ABSORBED FROM THE ENVIRONMENT
2
The refrigerant evaporates and flow into the
compressor where it is compressed and superheated
CONDENSER Gives out the heat energy
3
The superheated compressed refrigerant passage
through the copper tube coiled round the Heat
Recovery Water Tank
3
SOLAR HEAT
Tank Construction
Hot Water Systems
Service Valve
Service Valve Bracket
Top Lid
Dip Tube
PT Valve
Sacrificial Anode
P.U Foam
Copper Tube 3/8
Water Inlet
Jacket
E.P.S Foam Base
Thermostat
Bottom Lid
Area
4
SOLAR HEAT
Key Elements
Hot Water Systems
Most heat pump and air-conditioner water heaters
have their hot and aggressive vapor refrigerant
tube direct contact with the storage water. This
poses the danger of the stored water to be
contaminated by the refrigerant in event there
is R22 which all contain the hazardous chemical.
The ecogen Heat Recovery System does not pose
any threat of contamination to the storage water
in the event that the refrigerant vapor leaks
because the refrigeration coils are not in direct
contact with the water.
ecogen Heat Pump Water Heater
ecogen Heat Recovery Water Heater
Other Hot Water Generation System
5
SOLAR HEAT
Sedna Aire Hot Water
Hot Water Systems
Heat Recovery Water Heater
Storage Tank / Clarifier Tank
Heat Pump Water Heater
1 1.5 HP
2 3 HP
60litres, 90 litres and 340 litres.
3 5 HP
Series Compact Unit 1.1kW (RC) Series Split
Unit 1.8kW (CC)
6
SOLAR HEAT
Hot Water Systems
Frequently Asked Questions
Q Do I need to turn on my air conditioner
whenever I need to use hot water? A No. You do
not need to do so. Once the air conditioner has
been on for 2 hours, the hot water can be
retained as the ecogen hot water tank well
insulated. If its not used, the hot water can be
retained for a number of days. Q How long does
it take to heat the hot water? A For 1 HP (9k to
12k BTU) air conditioner with the ecogen 60
Liters tank the water can be heated up from 28
degrees C to 40 degrees C in ½ hour and 60
degrees C in 2 hours. Q How much approximately
I can save by using the Sedna Air ecogen system?
A 100 of your current cost for producing hot
water! You are using free energy! Q What is the
requirement to install? Do I need to change my
air conditioner? A No. You do not have any
special requirement to install a Sedna Aire
ecogen system it can be used with any brand of
the air conditioner! Q Will my air conditioner
consume more electricity? A No. a Sedna Aire
ecogen system in fact reduces work done by
condenser thus 9.8 less wattage of electricity
is consumed by the air conditioner. Q Will it
damage my air conditioner or compressor? A No.
It will not damage your compressor as the heating
coil for the air con is not immersed in the water
thus preventing any contamination of water with
refrigerant and vice versa. Q Is the
maintenance cost high? A No. As there are no
moving parts in the Sedna Aire ecogen system,
there is no maintenance cost at all. Q How does
it help the environment? A The Sedna Aire ecogen
system extracts the discharged heat from the
compressor of the air conditioning unit before it
is vented outside to heat water. This will
protect the environment by drastically reducing
greenhouse gas (CO2) emissions compared to
virtually all other form of heating and this also
reduce the amount of heat being discharged to the
environment by the air con thus helping in
reducing global warming.
7
SOLAR HEAT
Comparisons
Hot Water Systems
Cost Comparison of Hot Water Generation Methods
8
SOLAR HEAT
References
Hot Water Systems
Jumeirah Meradhoo Resort, Maldives Heat
Recovery System AL270DC 35 Units
Four Seasons, Langkawi
Heat Recovery System AL340 60 Units
Cinnamon Island Alihood,
Falhumaafushi Resort, Maldives Heat Recovery
System AL270 98 Units
Heat Recovery System AL150 50 Units
Lone Pine Hotel, Penang
ILOILO Suites, Philippines Heat Recovery
System AL90DC 20 Units
Heat Pump 340T2 15 Units Storage Tank 11
Units
Cinnamon Lodge, Sri Lanka
Hotel Putra Muda, Malaysia Heat Pump 340T2 4
Units Storage Tank ST340 4 Units
Heat Recovery System AL60 16 Units, AL90(DC)-14
Units AL120(DC) 13 units
Please feel free to contact any of these
references
9
SOLAR HEAT
References
Hot Water Systems
Four Seasons, Maldives Heat Recovery
System AL340 50 Units
Kuredu Resorts, Maldives Heat Recovery
System AL150 50 Units
Baros Resorts, Maldives Heat Recovery
System AL150 30 Units
Kandooma Tourist Resort, Maldives Heat Recovery
System AL60 32 Units, AL270 2 Units
Anantara Resort, Maldives Heat Recovery
System AL60 6 Units, AL90 -160 Units, AL150
275 units
Alamanda Resort, Seychelles Heat Recovery
System AL150 100 Units
Fullmoon Resorts, Maldives Heat Recovery
System AL60 25 Units, AL90 -50 Units
Four Seasons, Seychelles Heat Recovery
System AL270 60 Units
Please feel free to contact any of these
references
10
SOLAR HEAT
References
Hot Water Systems
Nanyang Technology University Heat Pump 340Ti
30 Units Storage tank 9 units
Sonaisali Island , Fiji
International Islamic University, Malaysia Heat
Pump 340T2 56 Units Storage tank 21 units
Vatulele Island Resort, Fiji
Shangrila Residences, Singapore
Sunway Resort Spa, Malaysia Heat Pump 340T2
2 Units Storage Tank 2 Units
Sunway Convention Hall, Malaysia Heat Pump
340T2 4 Units (Function Room Kitchen)
Raffles Hotel, Singapore (2001)
Please feel free to contact any of these
references
11
SOLAR HEAT
References
Hot Water Systems
Sheraton Hotel, Tasmania
Indo Chine Restaurant, Singapore
TTS Hospital, Singapore
Laguna Country Club Resort, Singapore
Please contact any of these references.
Additional references are available.
12
SOLAR HEAT
Gallery
Hot Water Systems
Four Season Resorts Langkawi
13
SOLAR HEAT
Contact Us
Hot Water Systems
Advance Solar Construction LLC 7008 Dusty
Rd Riverview Fl, 33708 813-677-7373
Write a Comment
User Comments (0)
About PowerShow.com