Phobos Magnet Status - PowerPoint PPT Presentation

About This Presentation
Title:

Phobos Magnet Status

Description:

Phobos Magnet Status Leslie Rosenberg & Patrick Decowski, MIT Technical Advisory Committee November 1998 Magnet Design Phobos Magnet is: Double dipole Resistive coils ... – PowerPoint PPT presentation

Number of Views:98
Avg rating:3.0/5.0
Slides: 15
Provided by: Deco151
Learn more at: https://www.sdcc.bnl.gov
Category:

less

Transcript and Presenter's Notes

Title: Phobos Magnet Status


1
Phobos Magnet Status
  • Leslie Rosenberg Patrick Decowski, MIT
  • Technical Advisory Committee
  • November 1998

2
Magnet Design
  • Phobos Magnet is
  • Double dipole
  • Resistive coils
  • 2 Tesla in spectrometer
  • Low Field outside of spectrometer

100 MeV/c
1 GeV/c
3
The Phobos Magnet _at_ Danfysik
4
Manifolding
5
More Manifolding
6
Coils
7
Factory Acceptance Tests
  • Factory Acceptance tests were conducted on Oct 1
    2 _at_ Danfysik
  • Voltage drop, Pressure drop, Temperature rise
    were measured. All according to Specs
  • At 1/7 of the nominal magnet current
  • B 0.4 T in center
  • Field is uniform, no surprises
  • No measurable deflection at this reduced current
    setting.

Magnet passed Factory Acceptance tests!
8
Magnet Arrival _at_ BNL
9
Safety Review
  • The Phobos Magnet was reviewed by the Safety
    Commitee in Feb. 98
  • Some action items arose, a response to the action
    items was submitted to the Safety Committee
  • We are working with J. Scaduto to generate
    procedures for operating the magnet. These will
    be refined while the magnet is at the AGS
  • Magnet Stand was designed
  • Seismic tie-down (action item from the safety
    review)
  • 3-axis adjustment

10
Magnet Stand Design
Top View
Horizontal Movers
Side View
Vertical Adjustment
Bolts screw into bolt holes in yoke
Tie-down to the tunnel floor
11
Field Mapping
Determining number of points for field map
By field in y0 plane
Max. absolute By gradient
12
Field Mapping II
By field weighted by the gradient
  • Strategy
  • measure one arm in detail, other in a few points,
    use symmetry
  • 45 deg trajectories
  • 3cm spacing between trajectories (40
    trajectories)
  • B measurement every 1cm along trajectory
  • 3cm vertical spacing (5 planes in gap)
  • 1 trajectory 1/2 hrs

Trajectories of probe
40x5x0.5 100hrs for one current setting
13
Schedule
  • Nov 3 Magnet arrives _at_ BNL
  • Nov 3 - Dec 2 Commissioning of magnet _at_ AGS
  • Assembly of components
  • Interlock sensors
  • Manifolding Buss-bars
  • B-field and mechanical tests _at_ full power
  • Dec 7 Move magnet to RHIC
  • Dec 8 - 18 Commissioning of magnet _at_ RHIC
  • Power and cooling
  • Hook up with RHIC controls
  • Dec 21 - Jan 29, 99 Mapping of magnet
  • AGS magnet mapping group

14
Summary
  • Phobos Magnet is on-track!
  • Magnet is delivered to BNL
  • Full power tests will be conducted at the AGS
    this month
  • The magnet will be moved to RHIC in early
    December
  • Magnet mapping will start in January
Write a Comment