The Fumigation Monitor Company - PowerPoint PPT Presentation

1 / 26
About This Presentation
Title:

The Fumigation Monitor Company

Description:

The Fumigation Monitor Company. Integrated Fumigation Monitoring &Web Based Data Acquisition. Methyl Bromide & Alternatives Conference. Surabaya, Indonesia – PowerPoint PPT presentation

Number of Views:158
Avg rating:3.0/5.0
Slides: 27
Provided by: govt70
Category:

less

Transcript and Presenter's Notes

Title: The Fumigation Monitor Company


1
The Fumigation Monitor Company
Integrated Fumigation Monitoring Web Based Data
Acquisition Methyl Bromide Alternatives
Conference Surabaya, Indonesia PART 2
2
Sulfuryl Fluoride SO2F2
3
  1. Corrects Temperature Differences
  2. Compensates for Pressure Changes
  3. Gas Specific NO Interference Gases
  4. Calibration (14,000Sensors)
  5. NOT EMF Susceptible
  6. Consistent Ideal Gas Law PVnRT

4

???????gt????gt????
??????????????????

       ??,??????????????????????????????????????????????????????????????????????????,?????????????????????????,?????????????????????????,??????????????????????????????????
????
5
Warehouse SF Fumigation
6
Warehouse SF Fumigation
Gas Added
7
(No Transcript)
8
Methyl Bromide
CH3Br
9
(No Transcript)
10
(No Transcript)
11
Shanghai CIQ Quarantine Fumigation
12
Shanghai CIQ Quarantine Fumigation 20-30 Error
with Thermoconductivity Monitor (NO PT
Correction)
start time Duration Container Position ?? reading(g/m3) reading(g/m3) reading(g/m3)
start time Duration Container Position ?? MB3000 MB-ContainIR ZR-A
11/5/2008 1200 26 hours 011031 bottom 22? 43 42.8 55.9
11/5/2008 1213 20 hours23mins 022435 bottom 22? 63 63.4 88.3
11/5/2008 1340 27hours40mins 011031 top 22? 34 34.2 42.2
11/5/2008 1430 22hours40mins 022435 top 23? 58 59.0 87.2
11/5/2008 1435 28hours35mins 011031 bottom 23? 41 40.9 56.3
11/5/2008 1440 28hours40mins 011031 top 23? 35 34.8 47.2
11/5/2008 1450 23hours 022435 bottom 23? 62 61.6 72.6
11/5/2008 1510 10mins 228489 bottom 23? 123  124.0 147.2
11/5/2008 1520 29hours20mins 011031 middle 23? 41 40.6 55.7
11/5/2008 1530 35mins 336106 bottom 23? 85 83.9 109.2
11/5/2008 1540 45mins 401681 bottom 23? 82 81.3 109.4
13
APPROVED
USDA Test of Methyl Bromide MBContainIR LV1008
12/17/2007 MeBr at Lab Temperature - Spectros Test MeBr at Lab Temperature - Spectros Test MeBr at Lab Temperature - Spectros Test MeBr at Lab Temperature - Spectros Test MeBr at Lab Temperature - Spectros Test LV1008

Pr. Temp. PPM per Air MeBr PPM g/m3 Spectros Difference
mm Hg C g/m3 ml ml Calc. Calc IR-g/m3 Calc-Instr.
748.0 28 264.44 8000 20 2,494 9.4 9.5 0.1 0.7
753.2 28 262.61 8000 40 4,975 18.9 18.6 -0.3 -1.8
748.2 28 264.37 8000 80 9,901 37.5 37.4 -0.1 -0.1
748.0 28 264.44 8000 120 14,778 55.9 56.9 1.0 1.8
748.0 28 264.44 8000 160 19,608 74.1 74.7 0.6 0.7
749.7 28 263.84 8000 240 29,126 110.4 110.5 0.1 0.1
749.9 28 263.77 8000 320 38,462 145.8 145.0 -0.8 -0.6
749.9 28 263.77 8000 420 49,881 189.1 187.4 -1.7 -0.9
750.5 28 263.56 7800 500 60,241 228.6 225.5 -3.1 -1.3
751.5 28 263.21 8000 600 69,767 265.1 262.1 -3.0 -1.1
751.5 28 263.21 8000 700 80,460 305.7 302.5 -3.2 -1.0
752.1 28 263.00 8000 800 90,909 345.7 339.3 -6.4 -1.8
752.5 28 262.86 8000 1000 111,111 422.7 418.0 -4.7 -1.1
14
MBContainIR is USDA Approved
APPROVED
15
Apples from New Zealand to Japan
Compliant Quarantine Pre Shipment
Certification
16
APPROVED
17
Web Based Fumigation Monitoring Data
Acquisition
18
Web Based Platforms
  • Hardened Enclosure
  • Advanced Infrared Technology (NDIR)
  • Solid State Electronics
  • Modular Components
  • Multiple Sample Positions
  • Web Based Data Acquisition Management

NEMA Fixed
Transportble
19
Encrypted, Flexible ,Secure Data
Transmission
20
Secured, Encrypted Website
21
Threshold Settings for Action Alerts
22
Main Networking Functions FTP-Based File Transfer
23
Electronic Notebook Traceable to Compliance
  • USA Federal Register 21 CFR Part 11
  • Calibrated Fumigant Gas Cylinder
  • Spectros Monitors Pressure and Temperature
  • Calibration Verification Onsite and Individual
    Fumigation Proof of Compliance
  • Encrypted Transfer of Secured Data Like Bank
    Transfer
  • Government Enforcement PROOF

24
China CIQ Chile SAG
  • AN ENCRYPTED WEB BASED TRANSFER OF FUMIGATION
    DATA
  • STEP1 Fumigation Collects CxT Secured Data
  • STEP2 Method Defined CxT has Spectros Issues
    Certificate Pass/Fail
  • TRACEABLE TO CERTIFIED CALIBRATION GAS
  • STEP3 Good Fumigation gets Spectros Notification
    to Customer/ Government
  • Agency Protected Server
    (ENCRYPTED)
  • STEP4 Governing Agency Issues THEIR TRACKING
  • (Unique and No Way to Counterfeit)
  • STEP5 This Used by Brokers/Forwarders/Shipping
    Companies
  • USA FEDERAL REGISTER Electronic Notebook 21CFR
    Part 11

25

Poor Fumigation Monitoring Proof Increased
Pest Resistance!
Vs.
26
Thank You Dennis Glennon Ph.D. Chief Technology
Officer Spectros Instruments, Inc. 17D Airport
Road Hopedale, MA USA Office 508.478.1648 Direct
508.579.6301 dglennon_at_spectrosinstruments.com
Write a Comment
User Comments (0)
About PowerShow.com