Title: Diapositiva 1


1
Electro-optical Spectro-polarimeter for Ground-
and Space-based Solar Coronagraphy S.
Fineschi, INAF-Osservatorio Astronomico di
Torino, Italy
2
OUTLINE
  • Proba-3 ESA Formation-flying space coronagraph
  • LC Tunable-filter Polarimeter (LCTP) for the
    green line
  • LCTP Lab performances evaluation
  • Eclipse 2010 observations with LCTP prototye
  • Case for ground-based emission-line coronagraphy
    in Europe

3
ESA PROBA-3 (ESA Startiger 2009-10 Phase-A)
Formation-Flying Coronagraph
A coronagraph with the external occulter on one
spacecraft and the optical instrument on the
other spacecraft at 150 meters from the first
one.
Proba-3 ESA launch 2017. ASPIICS 2009
selection 2010 Phase-A (Startiger) 2012 Phase-B
4
ASPIICS
LC Lyot filter
5
Liquid-crystal Tunable Lyot Filter for Solar
Coronagraphy
6
LC Tunable-filter Polarimeter Procurement
7
LCTP Perfomances
8
SET-UP _at_ TURIN Astronomical Obs. LAB
Monochr. slit width 25 µm height 6
mm Monochr. spectrum CW 530.3 nm FWHM
0.1nm Collim. lens (L1) f 140 mm Camera lens
(L2) f 1130 mm CCD pixel sixe 25? Spatial
scale 5 arcsec/pix (ASPIICS 3 arcsec/pix)
9
LCTP SPECTRAL tests
10
0
45
90
135
11
LC SPACE VALIDATION (rad-hardness)
  • Proba-3 rad-hard requirement
  • (Summary Mission Requirements ESA
    P3-EST-TN-7002)
  • 1996 ? 1.5 Mrad of lt 32 MeV e- (Graham et al.,
    SPIE 2811)
  • 1998 ? 12 krad of ? 20 MeV protons (Noto et
    al., Opt. Eng.)
  • 2007 ? 50 krad of ?-rad Thermal-vac Vibe
    tests
  • (Heredero et al., Appl. Opt. 46)
  • 2009-2010 ? 50 krad 100 MeV p, 10 MeV e-
  • ESA-ITT LC Space Validation for SolO

12
The CorMag was operated during the total solar
eclipse of July, 11th 2010 on Tatakoto Atoll
(French Polynesia)
13
LCTP based spectropolarimetercormag
14
Coronal Temperature contour levelsBlue
1.5?106 Kgreen 2?106 K
K-corona image by M. Drukmuller
15
HAO CoMP LC Lyot filter Polarimeter FeXIII
1074.7 nm
S. Tomczyk, et al. Science 317, 1192 (2007)
16
COMP observations. HAO model . S. Gibson
courtesy, 2012
17
CoMP-S instrument _at_ Lomnicky Peak Observatory
(SLOVAK R.)
18
LCTP FILTER _at_ CLIMSO CORONAGRAPH PIc du midi
(france)?
19
LCTP FILTER ASPIICS telescope _at_ DOMEc
French-italian concordia base (antartica)?
Sky Brightness Monitor _at_ Concordia J. Arnaud, M.
Faroubert, 2009
ESCAPE proposal L. Dame, 2011
20
Thanks !!!
21
Liquid-crystal Tunable Lyot Filter for Solar
Coronagraphy
  • The LCTP achieves all the spectroscopy
    performances expected from the F-P etalon
  • The LCTP has additional science capabilities
    (e.g., polarimetry, simultaneous spectroscopy
    high-res imaging)
  • ESA completed a LC space validation program
  • The LCTP operational advantages
  • no mechs,
  • some science preserved even in fail state,
  • OPS monitoring capability also during coronal
    images acquisition

22
SET-UP _at_ OATo LAB
23
Monochromator setting Center wavel. 530.3
nm FWHM 0.1 nm
24
LCTP vs. F-P etalonSpectroscopy
25
LC Tunable-filter
26
LCTP and F-P Characteristics
Liquid-crystal Tunable Lyot Filter for Solar
Coronagraphy
27
LCTP based SPECTRopolarimeter - cormag
28
LCTP based spectropolarimetercormag
29
(No Transcript)
30
(No Transcript)