Title: THE UNIVERSITY OF ATHENA
1 THE UNIVERSITY OF ATHENA
Aristotelis Vasiliadis Athanasios Balafoutis Riza
Fatih Mendilcioglu Ludovic Vanquin
2OUTLINE
- INTRODUCTION ARCHITECTURAL CHARACTERISTICS
- CURRENT STATUS
- LIGHTING CONCEPT DECISIONS
- LUMINAIRES
- FINAL RESULT
- IF THERE WAS MORE TIME.. THINGS TO CONSIDER
ABOUT
3- 1.INTRODUCTION ARCHITECURAL CHARACTERISTICS
- The main building of the University of Athens
- designed by the Danish architect Hans Christian
Hansen - constructed between 1839 and 1842
- Today
- headquarters of the University of Athens
- houses the offices of the Rectorate, the
Juridical Department, the Archives and the
Ceremonial Hall for official ceremonies refering
to the University community.
- INTRODUCTION ARCHITECTURAL CHARACTERISTICS
- CURRENT STATUS
- LIGHTING CONCEPT DECISIONS
- LUMINAIRES
- FINAL RESULT
- IF THERE WAS MORE TIME.. THINGS TO CONSIDER
ABOUT
4 1. INTRODUCTION - ARCHITECTURAL
CHARACTERISTIC OF THE BUILDING
- The Building
- Neoclassical style with a double T or H shape
- Two symmetrical courtyards
- Strictly symmetrical facade with an Ionian-style
entrance - Entrance emphasized by two heavy columns with
impresive capitals, similar architecture to the
Propylaea of Acropolis - Classical fresco on the inner walls designed by
the Bavarian Karl Rahl and painted after 1888 by
Eduardo Lebiedzky
5- The Exterior
- Five statues stand in front of the building,
commemorating important figures of the modern
Hellenic history (William E. Gladstone, Rigas
Pheraios of Velestino, Gregorios V,Count, loannis
Kapodistrias, Adamantios Korais). - Exterior consists of stone and green areas,
formatting a circular entrance space. Two marble
fountains at the front of the entrance complete
the scene. - There also two paths that climb up sideways, at
the front of the building.
62. CURRENT LIGHTING STATUS
- SPOT PROJECTORS FOR THE FRESCO
- LINEAR LIGHTING OF THE UPPER TRIANGLE OF THE
BUILDING - TRADITIONAL LUMINAIRES FOR THE SURROUNDINGS
- PATHWAY MARKERS (NOT WORKING)
72. CURRENT LIGHTING STATUS (Cont.)
- Actually, we saw no light nor water in the
fountains!!
83. LIGHTING CONCEPT - DECISIONS
- Aims and goals
- Emphasize the functionality of the building ( a
place for learning, communication and
intellectual exchanges). - Show the historical and cultural characteristics
of building. - Use the lighting to create an attractive
atmosphere. Visitors are invited to feel
attracted and curious to explore. Emphasize the
hug-shaped entrance. - Arrange the surroundings to create a friendly and
calming place. - Emphasize the green space, highlight the
fountains and the statues. - Finally Playing with columns and fresco, giving
the impression of a book that is ready to reveal
its content but not without effort.
93. LIGHTING CONCEPT DECISIONS (Cont.)
103. LIGHTING CONCEPT DECISIONS (Cont.)The model
113. LIGHTING CONCEPT DECISIONS (Cont.)General
luminaire arrangement
12- 4. LUMINAIRES USED - CHARACTERISTICS
13AmazonLED² Ground marker used to show the hug
shape of the entrance Type BBC200 (230 V,
class II version) BBC201 (24 V, class
IIIversion) Light source Integral
LED-module Power (/-10) BBC200 lt 2 W BBC201 lt
1 W Luminous flux Warm white (WW) 20 lm Blue
(BL) 5 lm Correlated Color Temperature 3000
K Color Rendering Index 80
Maintenance of lumen output - L70 35,000 hours
at 35ºC Operating temperature range -20 to
35ºC Driver BBC200 integrated BBC201 not
integrated Mains voltage BBC200 220-240 V /
50-60 Hz BBC201 24 V DC Inrush current 100 mA
at 14 ms Optical cover Opal cover
Material Ringstainless steel, grade
316x Optical cover polycarbonate, opal,
UV-stabilized Connection Delivered with mains
cable, 20 cm of length Installation Ground
recessed Cable gland M20 Accessories Tube for
installation in concrete/ asphalt, ZBC200
TUBE Pack of 10 transformers 230/24 V, EBC201 PSU
230/24V (10 pieces) 1 transformer 230/24 V,
EBC201 PSU 230/24V
14C-Splash 2 Underwater color luminaire to be used
in the fountains
Type BCP468 Light source Integral
LED-module Power 25 W Beam angle 10º (clear
lens) or 22º (frosted lens) Luminous flux 583 lm
(10º), 515 lm (22º) Luminaire efficacy 20.6 lm/W
(frosted lens) / 23.3 lm/W (clear
lens) Maintenance of lumen output - L50 50,000
hours at 50ºC
Operating temperature range -20 to 50ºC Driver
Integrated Power/Data Supply PDS-60 24 V supply
for indoor and outdoor applications PDS-150e
supply for Ethernet and DMX installations Mains
voltage 24 V DC Dimming Digital via PDS-60 24V
or PDS-150e Material Housing cast brass Lens
clear or frosted tempered glass
Connection 18.3 m unified power/data
cable, standard, 45.7 m maximum 121.9 m total per
power/data supply Installation Surface mounted
15eW Burst Compact Powercore
Spot luminaire used to accent the trees Type
BCP463 Light source Non-replaceable LED
module Available in white (2700K or 4000K) as
well as 4 solid colors (Red, Blue, Green,
Amber) Power 20 W max. at full output Beam angle
8º primary optic 14, 23 or 41º spread lenses 10 x
41º asymmetric spread lens Luminous flux 624 lm
(8º), 543 lm (14º), 540 lm (23º), 520 lm (41º),
557 lm (10 x 41º) - 2700 K 812 lm (8º), 685 lm
(14º), 674 lm (23º), 646 lm (41º), 695 lm (10 x
41º) - 4000 K
Correlated Color Temperature 2700 K, warm
white 4000 K, neutral white Color Rendering
Index gt 82.6 (2700 K) or gt 80.6 (4000
K) Maintenance of lumen output - L50 120,000 hrs
at 25ºC Maintenance of lumen output - L70 90,000
hrs at 25ºC 45,000 hrs at 50ºC Operating
temperature range -40 to 50ºC operating -20 to
50ºC start-up
Driver Built-in Mains voltage 100-277 V AC /
50-60 Hz Optic Symmetrical and asymmetrical
with spread lenses Maintenance No internal
cleaning required
16(No Transcript)
17iW Burst Compact Powercore
- Spot luminaire of variable CCT used to accent
- - the fresco
- - the upper part of the building
- - the statues
- - the columns of the entrance
- Type BCP464
- Light source Non-replaceable LED module
- Beam angle 8 primary optic
- 14/ 23/ 41 spread lenses
- 10 x 41 asymmetric spread lens
- Correlated Color Temperature
- Warm white, 2700 K to cool white,
- 6500 K
Operating temperature range -40 to 50C
operating -20 to 50C start-up Driver Separate,
to be ordered separately Via Data Enabler Pro
(DMX or Ehernet) Mains voltage 100-240 VAC /
50-60 Hz via Data Enabler Pro
Controls system input Philips full range of
controllers, including Light System Manager
and iPlayer3, or third-party DMX
controllers Optic Symmetrical and asymmetrical
with spread lenses Material Housing
high-pressure, die-cast aluminum, powder-coating
finished Glass tempered Mounting bracket
high-pressure, diecast aluminum, powder
coating finished
18(No Transcript)
19(No Transcript)
20(No Transcript)
21(No Transcript)
225. And finally the results!!
235. And finally the results!! (Cont.)fresco 1
245. And finally the results!! (Cont.)fresco 2
255. And finally the results!! (Cont.)the
fountains
265. And finally the results!! (Cont.)water play
276. IF THERE WAS MORE TIME.. THINGS TO CONSIDER
ABOUT
- Examine different scenarios
- Examine lighting with respect to the two other
buildings which consist Athens's Trilogy - Full technical and economical analysis, regarding
various different types of luminaires - Exact photometric computations how much lux
needed and how much are finally delivered?
(insert virtual surfaces in Relux) - Regard mistakes done and have feedback
- Examine side views
- .. and maybe have a better presentation!
28THANK YOU FOR YOUR ATTENTION!