Title: FCS/IB
1 FCS/IB DES SISPI WORKSHOP FERMILAB MARCH
13, 2007
2(No Transcript)
3Focus on the FCS and IB
Here behumans
Where isFocus?
DTS
to DM
4Proposed SISPI and Front End Network Showing Bulk
Data Rates (MBps)
DAQ electronics
Fiber
Ethernet
PCs
DTS (not SISPI) Data staging on mountain
21
4
24-port switch
lt 21 ?
Database
the same
5How should DES represent its system? E.g. as a
state machine? For now, make tables for the
FCS and for the IB, of the senders and receivers
of 1. the Control and State information 2. the
Data
6FCS and IB Interfaces in SISPI Controls and
State
From ???? OCS FCSMSL FCSPANsw/DHE IB DTS
OCS FCS StateExposure DoneReady for Exposure DAQ State e.g.Image ID AcqdImage ID Done(Error to OCS? Alarms?)
FCSMSL ConfigureTake Exposure IDAbort?? TLV Status, Telemetry x
FCSPANsw/DHEs ? (Debugging) PAN DHE Instructions ? (DAQ State Via OCS) x
IB Next Exposure Data Ready State(Protocol Dependent) ? ? Subscribe tothe IB Image iD Acq State
DTS x x Publishes pxl data QA
7FCS and IB interfaces in SISPI Data
From ???? DB FCSMSL FCSPANs w/DHE IB/ QAFOCUS ?
DB Hardware Status?? ? QA DiagnosticsHardware Status(Hot ADC..) ??Focus Results
FCSMSL Configuration Calibration Data CCD RO DB Header Info (more?) Hardware Status x
FCSPANs x Configuration Calibration Data CCD RO DB Header Info (more?) x
IB Configuration Calibration Data Hardware Status(e.g., Dead pxls) Other Header Info? x Pixel DataMetadataTelemetryOther Header Info ?
DTS x x PXL Dataw/Metadata
Display Gui History Plots DAQ status (Expert Only) Image DisplayQA DiagnosticsHardware Status(Hot ADC..) ??
8The Data (IB/QA?DB) will include diagnostic and
monitoring data. What information needs to be
collected for the history displays, from the data
and from the metadata ? E.g., occupancy/CCD,
ltPHgt /CCD. Other questions, also about the
data flow, outside FCS and IB, include Who
will be responsible for the DTS ? (SISPI or
NOAO)Will the DTS send data to DM, and to the
local data storage on the mountain (3 days
worth) ? Display Gui will it need to have
access to all pxl data, to make a partial HR
display, as well as a low resolution display of
the whole array?
9(No Transcript)
10Extra slides 1. Start of the list of commands
and data 2. Data, Metadata 3. CCD Readout and IB
Data Base Requirements
11Initial list of commands and data for discussion
OCS ? FCS
Set Focal Plane Configuration
Take Exposure
Abort Exposure
?
OCS ? IB
Next Exposure
Stop
?
FCS ? IB
Data Ready State
?
FCS ? OCS
Problem wexposure
?
FCS ? Database
Telemetry signals such as CCD temperatures
Focal Plane Configuration
Status of DHE
?
IB ? OCS
Image ID Acqd
Image ID Done
Problem with IB
?
12Data and Metadata
Pixel Datastandard FITS format (Multi-Extension
FITS ?)headers need a list of requirements
MetadataMonsoon board IDs CCD ? PAN/Address
in crate/ADC-channel map/CBB-channel mapCCD
geometry mapCalibration constants information
Bias and clock voltage telemetry CCD and
environmental temperatureFocal plane
versionSoftware versionFocus and hexapod
positions Cryogenics Dewar pressure Shutter
performanceTelescope Status Environment
(weather, seeing)Other
13CCD Readout and IB Data Base Requirements
For each CCD the DB has CCD orientation- will
all be the same? (archive)CCD geometric location
in the array (probably stable? archive) e.g.
relative location x,y of the bottom left pixel
x(1),y(1) CCD voltage rail requirements
stable? archive?DHE map (must be able to
change) PAN, Crate, preamp1 and 2 ACQ card
slot, ACQ Card ID, ADC subaddress CBB card
slot, CBB Card ID, CBB subaddressDead channels,
light bulbs, defects etc special infoWe have to
be able to find DHE info for geometry key and
vv Geometry ? PAN/Crate/ACQ Card/ADC
subaddress(es)