Title: JAN VENTER MD
1Artisan Phakic IOL
JAN VENTER MD Optimax, laser eye
specialists London, UK
1
2Prediction for theFuture
- ? Phakic IOLs will increase
- ? LASIK will decrease
- ? Both will improve
-
3Normal Optics
? Closer to Nodal point better quality
vision ? Cornea Disadvantages ? Optical
correction needs to go inside the eye
Cornea
Lens
4Problems With Corneal Procedures
- Flap Induced aberrations
- Small ablations (night vision problems)
- - Eccentric ablation (diplopia)
- - Abnormal beam profile (lines loss)
? Distance from Nodal point ? Optical Problems
with LASIK
5Anatomical Problems
LASIK
? Corneal Ectasia ? Irreversable
Phakic IOL
? Minimal alterations in Optical
aberrations ? Minimal anatomical problems
6Artisan Advantages
? One size fits all ? Pupil Centration ? Myopia
Hyperopia - Astigmatism
7Artisan Disadvantages
? 5mm OZ Toric Glare ? PMMA 5 or 6mm
OZ 5.2 6.2mm incision ? Iris fixation
long term ? Claw disengagements ? ? Flare
8Anatomical Position
Endothelium IOL 2mm IOL Crystalline lens
0.5mm Endothelial cell count no ?
9Hyperopia
(75 eyes)
Mean age 38 years (from 22 to 54)
10Refractive outcome
87 within ? 1 D 65 within ? 0.5 D
pre SR equiv mean 5.88 D 1.57 D (from 2.50 to
10.00) post SR equiv mean -0.25 D 0.57 D (from
-2.00 to 1.25)
11Predictability
12Stability
13Efficacy
88 0.5 or better 22 1.0 or better
14Safety
35 gained 1 line or more 8 gained 2 lines or
more
15Myopia
(274 eyes)
Mean age 38 years (from 21 to 68)
16Refractive outcome
90 within ? 1 D 61 within ? 0.5 D
pre SR equiv mean -11.05 D 3.62 D (from
-24.00 to -4.13) post SR equiv mean -0.32 D
0.51 D (from -2.13 to 1.25)
17Predictability
18Stability
19Efficacy
94 0.5 or better 29 1.0 or better
20Safety
36 gained 1 line 20 gained 2 lines or more
21Toric Artisan lens Technical Specs
Overall diameter 8.5mm
Lens Width 5.0mm Optical
Diameter 5.0mm Height 1.04mm
Weight 10 OMG in Air Available
Powers Myopia -2.00 to -20.00D
Cylindrical Correction -1.00 to -7.00D
Hyperopia 2.00 to 12.00D Cylindrical
Correction -1.00 to -7.00D
22Artisan Toric
(136 eyes)
Mean age 38 years (from 17 to 59)
23Refractive outcome
91 within ? 1 D 72 within ? 0.5 D
pre SR equiv mean -10.31 D 4.46 D (from
-22.25 to 7.13) post SR equiv mean -0.20 D
0.48 D (from -2.125 to 2.625)
24Predictability
25Stability
26Efficacy
84 0.5 or better 25 1.0 or better
27Safety
55 gained 1 line or more 21 gained 2 lines or
more
28Endothelial cell count
Average endothelial cell count Pre-op 2809
cells/mm2 ? 555 Standard deviation Post-op
2988 cells/mm2 ? 514 Standard deviation
29Surgical Complications
Remove Artisan 2 Pupil block glaucoma 1
Additional treatment 15 Shallow A/C 10
Hyphema
5
18
30Conclusion
The predictability, efficacy and safety
were excellent in all 485 eyes implanted with
Artisan lens The resulting correction of
astigmatism is better than any Phakic IOL
currently available
31Conclusion
This is the first choice in Phakic IOLs
for correction of combined Myopia, Hyperopia and
astigmatism The new foldable Artiflex will allow
implantation through a 3.2mm incision. Will only
correct myopia. Toric Artiflex trial to start
early in New year
32Thank you
33Different Meanings of 20/20
P-IOL, Acuvue, Spectacles20/20, high contrast
acuity
Wavefront LASIK20/20, medium contrast acuity
Standard LASIK20/20, low contrast acuity
34(No Transcript)