Title: Selective removal of CO2 from a contaminated gas stream
1Selective removal of CO2 from a contaminated gas
stream
United Arab Emirates University College of
Engineering
Saber Mohammed AL-Ammari 199900156 Bassam
Mohammed AL-Hedhani 199900146 Faris AbuBaker
AL-Ameri 980711333
Faculty Advisor Dr. Mohamed Al-Marzouqi
2Introduction
- Carbon dioxide (CO2) is commonly found in natural
gas streams at levels as high as 3.5 . - Typical composition of the gas in UAE oil gas
industry
ADMA/OPCO Lab Manuals.
3Introduction
- There are several technologies for removal of CO2
from a gas mixture such as adsorption, cryogenic,
absorption and membranes. Each technology has
it's own advantages and disadvantages. - absorption is widely used for CO2 removal,
especially in the United Arab Emirates. - the main drawback of the absorption process is
the need for the high amount of amine along with
the high regeneration cost.
4Introduction
- In order to overcome this drawback, we propose
membrane contactors for CO2 removal from a gas
mixture. - The advantages of membrane contactors are
- lower capital and operating cost
- operational simplicity and high reliability, high
flux, high mass transfer rate - high CO2 removal efficiency
- environmentally friendly.
5Material Balance
6Material Balance
Boundary conditions at z 0, CA 0, CB
CB initial at r 0,
(Symmetry)
at r R1,
7Material Balance
Boundary conditions at r R1,
at r R2,
8Material Balance
Boundary conditions at z L,
CAg CAinitial at r R2,
at r R3,
(Symmetry)
9Modeling Results
- Femlab was used to solve the set of non-linear
differential - equations.
10Modeling Results
11Modeling Results
- Factors affecting carbon dioxide removal
efficiency and total flux - Solvent Concentration
- Solvent Average Velocity
- Feed CO2 Concentration
- Pressure Gradient in the shell side (-A
)
12Solvent Concentration
13Solvent Average Velocity
14Feed CO2 Concentration
15Pressure Gradient in the shell side (-A)
16CO2 Flux values in shell and tube (shell at r
0.000297, z 0.00298) (Tube at r 0.00004, z
0.000298)
CO2 Flux values in shell and tube (Shell at r
0.000297, z 0.00003) (Tube at r 0.00004, z
0.00003)
The diffusion flux is the dominant flux in the
shell side while the reaction term is dominant
in the tube side
17Membrane and solvent membrane Selection
18Membrane and solvent membrane Selection
19EXPERIMENTAL SET-UP
- A laboratory-scale unit was specially constructed
to study CO2-CH4 separation through membrane
contactors.
Membrane contactor.
Experimental set-up.
20Membrane Contactor
- The gas mixture was pumped through the shell side
of the contactor whereas propylene carbonate - Solvent was pumped through the fibers in a
counter-current flow. - Helium is used as a sweep gas to carry the
desorbed CO2 to the online gas chromatograph for
analysis.
21Experiment result
- Data generated (area under the curve vs. time) by
gas chromatograph (GC).
Area under curve vs. time generated by gas
chromatograph.
22Based on these data, the calculation of CO2 total
flux and percentage removal are explained as
followsThe percentage removal and CO2 flux are
calculated
removal
CO2 Flux
6.610E-6
23Conclusion of experiment
- The CO2 flux is less than the value reported in
the literature and predicated by modeling . - This discrepancy may be due to the problems in
desorption part since the complete removal of CO2
in desorption section was not possible using the
current set-up. - the propylene carbonate was not free of CO2 as it
was circulated through the system. Therefore, it
reduced the transport rate, due to smaller
concentration difference and as a result reduced
the CO2 flux and removal efficiency.
24Design Consideration
- Many process parameters can be adjusted to
optimize performance depending on the customer
and application needs. - Some typical requirements are
- Low cost
- High reliability
- High on-stream time
- Easy operation
- High hydrocarbon recovery
- Low maintenance
- Low energy consumption
- Low weight and space requirement
25The Scaling Procedures
- Requirements
- Gas mixture flow rate (from industry)
- The flux from experiments or (article)
- Outlet flow rate (estimated)
- removal (from industry)
- Area of the membrane (estimated)
- Tube and shell diameter of the membrane contactor
(estimated)
26Tube Side Calculation
27(No Transcript)
28Standard Specification
Final Results
29Shell Side Calculation
COULSON RICHARDSONS, Chemical engineering
design, R K Sinnot.
30Where Nt number of tubes do tube outside
diameter
31Amine Treating Unit
- The amine treating unit consist of six major
equipments depend on an information from ADNOC
company. -
32Heat Exchangers Capital Cost
33Materials for the Heat Exchangers
34Shell and Tube Heat Exchanger Purchase Cost Figure
The purchase cost (bare cost from figure)
type factor pressure factor
35The Purchase Cost of the Heat Exchangers
36CO2 and Regenerator Vessels Purchase Costs
The type for both vessels is packed bed. The
packing size 50 mm, (pall rings, stainless
steel). The packing height is 35 m. The material
that the both vessels consist of is carbon steel.
37Vessels Purchase Cost Figure
The purchase cost is 270000 for the CO2
absorber and 320000 for the regenerator.
38Packing Cost
39The Final Purchase Cost of Amine Treating Unit
The total purchase cost (PCE) the purchase
cost for (CO2 Absorber Regenerator Lean/Rich
DEA solution heat exchanger Lean DEA solution
cooler DEA Reboiler Condenser) 2141420
40The Final Capital Cost of Amine Treating Unit
41Total Capital Cost Total Purchase Cost (1
i( Total investment cost _at_ 2005 5371570
1.04 9007264
42The Operating Cost of the Amine Treating Unit
43 Summary of Production
Costs
44- Variable Costs
- Raw materials, solvent make up 342 kg/d 347
d/yr 1.35 /kg 160210 - Miscellaneous materials, 10 of maintenance cost
4124200.1 41242 - Utilities Cost
- Steam, at 12/t 128328(22871/1000) 2285636
- Cooling Water, at 0.01/t 0.018328(897000/1000
) 74702 - Power, at 0.023/MJ (2150/1000)0.02336008328
1482550 - Shipping and packaging, not applicable.
- Fixed Cost
- Maintenance, take as 5 of fixed capital
82484110.05 412420 - Operating labour, say 25000
- Laboratory costs, take as 20 of the operating
labour 250000.2 5000 - Supervision, 20 of the operating labour 5000
- Plant overheads, 50 of the operating labour
250000.5 12500 - Capital charges, 15 of the fixed capital
82484110.15 1237261 - Insurance, 1 of the fixed cost 82484110.01
824841 - Annual Operating Cost at 1998 4044340 2522022
6566362
45Membrane Cost
The area is 30070 m2. The fibers cost is 92.96
Euro/m2 (from literature search). The cost of the
tube side (fibers) of the membrane contactor will
be (in dollars) 30070 92.96 1.3 3633899.
The shell side is calculated as a vessel, using
the previous figure for shell and tube purchase
cost figure.
Membrane contactor purchase cost _at_1998 3633899
9000 3642899
46The cost index must be used after the purchase
cost was estimated, because it is in 1998 and now
we are in 2005. So, the purchase cost in 2003
for the process will be
Allowing 4 inflation from 2003 to 2005, so the
final purchase cost of the project _at_ 2005
3930496 1.04 4087716
47Total Capital Cost Total Purchase
Cost(1i) Total Capital Cost for the Membrane
Contactor _at_ 2005 14020866 701043 14721909
48The Operating Cost of the Membrane Contactor
-
- Fixed Costs
- Maintenance, take as 5 of fixed capital
140208660.05 701043 - Operating labour, say 25000
- Laboratory costs, take as 20 of the operating
labour 250000.2 5000 - Supervision, 20 of the operating labour 5000
- Plant overheads, 50 of the operating labour
250000.5 12500 - Capital charges, not applicable.
- Insurance, 1 of the fixed cost 140208660.01
140209 - Variable Costs
- Raw materials, solvent make up, not required.
- Miscellaneous materials, 10 of maintenance cost
7010430.1 70104 - Utilities Cost using table (..)
- Steam, not required
- Cooling Water, not required
- Power, not required
- Shipping and packaging, not applicable.
49Cost Comparison
- The main objective of our project is to reduce
the cost (specially the operating cost) of the
gas separation process in the oil fields, by
replacing the amine treating unit by a membrane
contactor.
The total cost difference between the two
processes after 20 years is 84.2 million dollars
50Environmental impact
- The good thing in membrane contactor system
comparing to other system of removing that CO2
removal collected where the other possess release
it to atmosphere. - The removal carbon dioxide that collected was
storage it to use in to other applications such
as in the soft drinks industry or fire protection
or inject it in oil reservoir to enhance oil
recovery.
Membrane Contactor injection or storage of
carbon dioxide.