Title: P1252428399WyGYx
1 Vision 6.0 Clinical Applications
2Vision Power Station
- Full panel cardiology software
- Industry Standard Applications (Emory )
- Complete Clinical Software Library
- Large panel of connectivity solutions
- Fast processing
3Vision Power StationCardiac SPECT Processing
- Up to 3 simultaneous reconstruction (stress,
rest, delay) - Any combination of gated and/or non-gated studies
- Sinogram, Linogram and raw cine mode quality
control - Fast assessment of wall motion, perfusion and
thickening - Slices cine mode for Gated SPECT studies
Read Master Display
4Vision Power StationCircumferential Profiles
Analysis
- Stress and rest dual study comparison
- Applicable to thallium or technetium agents
- Circonferential profiles with expected
redistribution - Perfusion and washout bullseyes
- Adjustable distribution 3D map
3D perfusion map
5Vision Power StationTARGET Bullseye
- Perfusion bullseyes display
- Thallium or technetium based perfusion agents
- Cedars thallium reference database (option)
- Multiple user-created databases
- Quantitative patient/database comparison
Comparison bullseye
Patient bullseye
6MultidimTM Comparative ProcessingOwnership gated
tomography protocol
- Up to 3 gated or non-gated datasets may be
analysed - 4D cine of the endocardial wall (3D surface
wall motion) - Solid or wire-mesh display
4D cine and physiological indexes
7MultidimTM Comparative Processing Ownership
gated tomography protocol
- LV EF and volume calculation
- ES, ED and stroke volumes, EF and cardiac output
computation - 3D mapping
- regional ejection fraction
- regional perfusion
- stress/rest subtraction (washout)
3D perfusion map
8Vision Power Station Planar Gated Bloodpool
- Automatic tail drop correction
- Automatic or manual Region-Of-Interest
- Left and right global ejection fraction
- Exercise gated comparison with up to eight
datasets - Fourier analysis
- amplitude and phase image
- contraction wave propagation
- Regional and sectorial EF
Functional images
9Vision Power StationStasis Motion Correction
- Correction for patient motion and cardiac creep
- Vertical and horizontal shifts treated
independently - Automated analysis of sinogram and linogram
- Compatible with both gated and non-gated
Linogram
Sinogram
10Vision Power StationRestore Resolution
Recovery
- Depth dependent resolution recovery
- Scatter correction
- Filter adjustement (maximum gain, cutoff,
filter-shape) - Collimator and acquisition setting
- Improves cardiac spect images quality
- enhances contrast between heart and background
- gives better definition of ventricular cavity
- leads to a more homogeneous visualization
3D map of Restore filter
11Vision Power StationTACTM Transmission
Attenuation Correction
- Myocardial SPECT non-uniform attenuation
correction - 153Gd or 99mTc as transmission source
- 201Tl or 99mTc-sestamibi as radiotracer
- Multi-iterative reconstruction optimization
- Chang algorithm
- Single or gated cardiac SPECT
Transmission map
12Vision Power StationTACTM Transmission
Attenuation Correction
- Eliminates non-uniform attenuation artifacts
- enhances activity in inferior / infero-spetal
regions - decreases relative activity of antero-lateral
region - decreases hyperactivity of apex
13Vision Power StationSPECT reconstruction / 3D
package
- Real time slice reconstruction for SPECT
acquisition - Decay, COR, uniformity post-acquistion correction
- Large choice of reconstructiuon filters
- 3D volume rendering or iso-surface display
Bone tomoscintigraphy
14Vision Power StationCerebral Blood Flow
- Regional brain flow quantification
- Dual SPECT comparison
- Automatic circumferential segmentation
- Segmental left/right and early/delay analysis
- Numeric and bar graphic display
Cerebral stroke
Circumferential analysis
15Vision Power StationRenal Package
- Automated processing
- DTPA, MAG3 and IOH acquisitions
- Renogram analysis
- Effective Renal Plasma Flow (ERPF)
- Glomerular Filtration Rate (GFR)
- Renal uptake, clearance and excretion assessment
MAG3 study
16Vision Power StationLungs Ventilation /Perfusion
- Analysis of pulmonary function
- Automated processing
- Global and segmental analysis
- Ventilation and perfusion time activity curves
- Functional images
- Ventilation index
- Perfusion index
- Vent/Perf ratio
- Mean transit time
Vent/Perf ratio
Image Histogram
17Vision Power StationWhole Body Processing
- Ant/Post single or dual study processing
- Full 10241024 screen display
- Hot spot masking
- ROI counts statistics
- Magnification tools
Whole body scan
18Vision POWERstation 6.0
- New Clinical Appliation
- PER (Scatter correction software)
- BrainQuant (Stereotaxic Brain Quantification)
- Myoflex (3D Myocarial Fuzzy Logic Expertise)
19PER - Scatter Correction
- Objectives
- Improve the effective energy resolution of
acquisition system, - Correct the images for
- Compton scatter
- Crosstalk down scatter contamination
- gt Multispectral analysis based on iterative
energy spectrum deconvolution - Benefits
- Better image contrast
- Improved spatial resolution
- More accurate quantification
20PER - Scatter Correction
Thallium Stress SPECT Scintigraphy
Without correction
With Scatter Correction
Inf. wall Ant. wall
Line profile through a middle VLA slice
21MyoFLEX
Processing steps
? ? ? ?
? ?
2D views
3D views
22MyoFLEX
- Automatic myocardial edge detection algorithm
- Perfusion 3D Quantification (3D ROI)
3D automatic analysis
23MyoFLEX
- 18 Sectors Segmentation
- Normal Reference Databases available
- User-defined databases capability
Myocard segmentation
24MyoFLEX
- Color-coded perfusion scores
- Relative tracer uptake distribution
- Simultaneous Rest / Stress analysis
- Reversibility 3D map (Rest-Stress)
Perfusion Mapping
25XT-ERNA 2 Multi-harmonic Fourier Analysis
- Automatic tail drop correction
- R-R waves histogram
- Automatic or manual Region-Of-Interest creation
- Left and right global ejection fraction
calculation - Multi-harmonic capability (1 or 3 harmonics)
- LV and RV percentile analysis
26XT-ERNA 2
- Exercise gated comparison with up to eight
datasets - Fourier analysis
- amplitude and phase image
- contraction wave propagation
- Sectorial EF
- Improved cine display
- Comprehensive result pages
- Standard display
- User-defined screens
27BrainQuant
- Anatomical localization of functional
abnormalities is difficult to implement in NM
without MRI and CT scan images.
?
Ability to identify cerebral structures by
comparing functional images with a standard
reference system (Talairach atlas).
28BrainQuant
Talairach grid
AC-PC orientation
- AC-PC plane determination and Talairach grid
applied on transverse cerebral slices
29Patient Motion Correction (MoCo)
- Can be launch from any SPECT Protocols
- Fully Automatics
- Support Gated SPECT
30QGS / QPS
Complementary (but similar) application referring
to Myocardial SPECT
31BPGS
Recon Reformat uses eNTEGRA UI, BPGS uses UI of
Cedars-Sinai.