Title: Status of Thermal Heat Balance Analysis


1
Status of Thermal Heat Balance Analysis
NSTX
Supported by
Art Brooks
College WM Colorado Sch Mines Columbia
U CompX General Atomics INEL Johns Hopkins
U LANL LLNL Lodestar MIT Nova Photonics New York
U Old Dominion U ORNL PPPL PSI Princeton U Purdue
U SNL Think Tank, Inc. UC Davis UC
Irvine UCLA UCSD U Colorado U Illinois U
Maryland U Rochester U Washington U Wisconsin
Culham Sci Ctr U St. Andrews York U Chubu U Fukui
U Hiroshima U Hyogo U Kyoto U Kyushu U Kyushu
Tokai U NIFS Niigata U U Tokyo JAEA Hebrew
U Ioffe Inst RRC Kurchatov Inst TRINITI KBSI KAIST
POSTECH ASIPP ENEA, Frascati CEA, Cadarache IPP,
Jülich IPP, Garching ASCR, Czech Rep U Quebec
NSTX Centerstack Upgrade Peer Review LSB,
B318 August 13, 2009
2
Planned Scope of Analysis
  • Assess Overall Heat Balance During Normal
    Operation
  • Heating of CS FW, Divertor, PP VV from Plasma
    including
  • RF Heating (High harmonic Fast Wave) max 4 MW
  • Neutral Beam Injection max 2x 5 MW
  • Total Power 14 MW for 5s at 1200s reprate
  • Initial Power 9 MW for 5s at 2400s reprate
  • For Reference, NSTX previously analyzed for 6 MW
    for 5s at 300s reprate
  • Active Cooling of VV, PP and Divertor
  • Heat Losses thru CS to OH1, PF1A,B and C
  • Evaluate Max Temperature Excursions of CS (and
    other Components)
  • Impact on Thermal Expansion of Center Stack
    Casing
  • Impact on Adjacent Coils

2
NSTX
August 13, 2009
NSTX Center Stack Upgrade Peer Review
3
Comparison of Averaged Heating Power
  • Total Power per Pulse has increased significantly
    while Pulse Duration has remained the same
  • May lead to higher first pulse FW temperatures
  • Mitigated in part by larger surface area of
    center stack
  • Rep rate is significantly longer at full power
  • Average heating (based on above??) is lower
  • Thermal Ratcheting expected to be relatively less
  • Pulse Power Distributed Assumed (based on prior
    analysis for natural divertor)
  • 30 radiative from plasma, uniformly distributed
    over exposed surfaces
  • 0.11 MW/m2
  • half of non-radiative power (35) to CS, other
    half to outboard divertor
  • GRD also specifies local Heat Flux and Power Flux
    width on PFCs (Table 3-2)
  • Max 15.5, Avg 9.8 MW/m2 to IBDHS
  • Max 6.3, Avg 4.0 MW/m2 to IBDAS IBDVS
  • Max 0.2, Avg 0.1 MW/m2 to CSFW

4
Power Distribution in Center Stack FW
14 MW
  • GRD Specification shows larger fraction of total
    power being dumped on center stack tiles than
    assumed in baseline analysis

5
Section Thru ProE Model of NSTX CSU
Areas of Concern
PF1C
PF1B
PF1A
OH (Not Shown)
6
2D Axisymmetric Radiation Exchange ModelGeometry
7
Heating, Cooling and Radiation Exchange
Plasma Heating of FW and exposed VV Radiation
Enclosure assumes emissivity of .7 for Graphite
tiles .27 for SS surfaces
Existing Active/Convectively Cooled Surfaces Need
to verify existing cooling parameters Cooling
to be added to new IBD
8
ANSYS Model with Boundary Conditions
9
Test Case
  • Assume All Heating dumped into Center Stack
  • 14 MW for 5 sec averaged over 1200 rep rate
  • Center stack area 8 m2
  • Steady State Average heat load 7291 w/m2
  • Assume Cooling at VV, PP, Outboard Divertor and
    Horizontal Inboard Divertor Section
  • Assume CS perfectly insulated from coils
  • Results in higher averaged temperature

10
Test Case SS Temperature Distribution
11
Test Case SS Temperature Distribution
12
Test Case - Overall Heat Balance
13
Work has just begun
  • Need to examine global transient behavior of
    Single and Double Null Divertor Plasmas as
    specified in GRD
  • Need to evaluate local heating of tiles
  • Need to confirm adequacy of existing cooling of
    VV, PP and Outboard Divertor