Title: Status of Thermal Heat Balance Analysis
1Status of Thermal Heat Balance Analysis
NSTX
Supported by
Art Brooks
College WM Colorado Sch Mines Columbia
U CompX General Atomics INEL Johns Hopkins
U LANL LLNL Lodestar MIT Nova Photonics New York
U Old Dominion U ORNL PPPL PSI Princeton U Purdue
U SNL Think Tank, Inc. UC Davis UC
Irvine UCLA UCSD U Colorado U Illinois U
Maryland U Rochester U Washington U Wisconsin
Culham Sci Ctr U St. Andrews York U Chubu U Fukui
U Hiroshima U Hyogo U Kyoto U Kyushu U Kyushu
Tokai U NIFS Niigata U U Tokyo JAEA Hebrew
U Ioffe Inst RRC Kurchatov Inst TRINITI KBSI KAIST
POSTECH ASIPP ENEA, Frascati CEA, Cadarache IPP,
Jülich IPP, Garching ASCR, Czech Rep U Quebec
NSTX Centerstack Upgrade Peer Review LSB,
B318 August 13, 2009
2Planned Scope of Analysis
- Assess Overall Heat Balance During Normal
Operation - Heating of CS FW, Divertor, PP VV from Plasma
including - RF Heating (High harmonic Fast Wave) max 4 MW
- Neutral Beam Injection max 2x 5 MW
- Total Power 14 MW for 5s at 1200s reprate
- Initial Power 9 MW for 5s at 2400s reprate
- For Reference, NSTX previously analyzed for 6 MW
for 5s at 300s reprate - Active Cooling of VV, PP and Divertor
- Heat Losses thru CS to OH1, PF1A,B and C
- Evaluate Max Temperature Excursions of CS (and
other Components) - Impact on Thermal Expansion of Center Stack
Casing - Impact on Adjacent Coils
2
NSTX
August 13, 2009
NSTX Center Stack Upgrade Peer Review
3Comparison of Averaged Heating Power
- Total Power per Pulse has increased significantly
while Pulse Duration has remained the same - May lead to higher first pulse FW temperatures
- Mitigated in part by larger surface area of
center stack - Rep rate is significantly longer at full power
- Average heating (based on above??) is lower
- Thermal Ratcheting expected to be relatively less
- Pulse Power Distributed Assumed (based on prior
analysis for natural divertor) - 30 radiative from plasma, uniformly distributed
over exposed surfaces - 0.11 MW/m2
- half of non-radiative power (35) to CS, other
half to outboard divertor - GRD also specifies local Heat Flux and Power Flux
width on PFCs (Table 3-2) - Max 15.5, Avg 9.8 MW/m2 to IBDHS
- Max 6.3, Avg 4.0 MW/m2 to IBDAS IBDVS
- Max 0.2, Avg 0.1 MW/m2 to CSFW
4Power Distribution in Center Stack FW
14 MW
- GRD Specification shows larger fraction of total
power being dumped on center stack tiles than
assumed in baseline analysis
5Section Thru ProE Model of NSTX CSU
Areas of Concern
PF1C
PF1B
PF1A
OH (Not Shown)
62D Axisymmetric Radiation Exchange ModelGeometry
7Heating, Cooling and Radiation Exchange
Plasma Heating of FW and exposed VV Radiation
Enclosure assumes emissivity of .7 for Graphite
tiles .27 for SS surfaces
Existing Active/Convectively Cooled Surfaces Need
to verify existing cooling parameters Cooling
to be added to new IBD
8ANSYS Model with Boundary Conditions
9Test Case
- Assume All Heating dumped into Center Stack
- 14 MW for 5 sec averaged over 1200 rep rate
- Center stack area 8 m2
- Steady State Average heat load 7291 w/m2
- Assume Cooling at VV, PP, Outboard Divertor and
Horizontal Inboard Divertor Section - Assume CS perfectly insulated from coils
- Results in higher averaged temperature
10Test Case SS Temperature Distribution
11Test Case SS Temperature Distribution
12Test Case - Overall Heat Balance
13Work has just begun
- Need to examine global transient behavior of
Single and Double Null Divertor Plasmas as
specified in GRD - Need to evaluate local heating of tiles
- Need to confirm adequacy of existing cooling of
VV, PP and Outboard Divertor