PMT pulse timing w a FADC - PowerPoint PPT Presentation

1 / 12
About This Presentation
Title:

PMT pulse timing w a FADC

Description:

PMT pulse timing w/ a FADC. FADC allows determination of pulse timing since ... A singe typical shower resolves event time to 65 ps. Other Features, 3-point method ... – PowerPoint PPT presentation

Number of Views:30
Avg rating:3.0/5.0
Slides: 13
Provided by: scot131
Category:
Tags: fadc | pmt | pulse | singe | timing

less

Transcript and Presenter's Notes

Title: PMT pulse timing w a FADC


1
PMT pulse timing w/ a FADC
  • FADC allows determination of pulse timing since
    several samples are taken during each PMT pulse
  • Several algorithms are possible
  • FEU-115 and FEU-84-3 are compared
  • Sub-nanosecond resolution is possible

2
Full fit method
  • A full fit of the pulse to the di-gaussian form
    is used
  • Typical pulse and fit result is shown

3
Five-point method
  • Pulse height is transformed to linearize via
  • F(v)(-ln(V/Vmax)).5
  • Five points are used to determine the time

4
Results for the FEU-84-3 (MC)
  • Solid curve is full fit method, dashed is
    five-point method
  • Full fit fails at low pulse height, defaults to
    bin center

5
Results for the FEU-115 (MC)
  • Solid curve is full fit method, dashed is five
    point method
  • Low pulse height remains difficult
  • Performance generally inferior to FEU-84-3

6
Experimental results (84-3)
  • A limited pulse library exists
  • Sampled with 8 bit precision, 0.5 ns sampling
    period
  • T0 is not known but is determined via fit to 9th
    deg. polynomial
  • Peak, 75, 50 and 25 crossing are used

7
5-point peak finding
  • The 5-point algorithm is used to locate the pulse
    peak time
  • Fail only on rare events
  • 426 ps resolution at 10 of full scale pulse.
    (better than MC)

8
5-point edge finding
  • Compare 5-point time to time of 50 crossing
  • Resolution slightly worse, 526 ps.
  • 50 crossing jitters about 200 ps relative to the
    peak

9
2-point edge finding
  • Use peak sample and sample 2 bins previous to
    interpolate to 50 crossing
  • Always works, 293 ps resolution

10
3-point edge finding
  • Use bins 1 and 2 samples before peak to
    interpolate to 50 crossing
  • Always works, resolution is 160 ps at 10 of full
    scale
  • A singe typical shower resolves event time to 65
    ps.

11
Other Features, 3-point method
  • 25 crossing s159 ps.
  • 50 crossing s157 ps.
  • 75 crossing s279 ps.
  • Peak time s339 ps.

12
Conclusion and Question
  • 250 MHz, 8 bits seems to maintain all features
    of PMT pulses
  • What feature carries the real timing
    information?