INTRODUCTION TO LFG INSTRUMENTS
2
SENSORY THEORY
  • CATALYTIC - PPM AND 0 TO 10 GAS (O2 DEPENDENT TO
    2)
  • THERMAL - 10 TO 100 GAS BY VOLUME (NON O2
    DEPENDENT)
  • CHEMICAL - O2, H2S, CO

3
GMI INSIDE CASE
4
GMI AND SAMPLING COMPONENTS
5
GMI BODY AND BATTERY
6
PROBE AND COMPONENTS
7
GMI IN COMBUSTIBLE GAS INDICATOR MODE USES AND
FEATURES
  • COMBUSTIBLE PPM RANGE
  • NO AUDIBLE OR VISUAL ALARMS
  • MANUAL DATA LOGGING ONLY
  • MANUAL RANGE VIEWING WITHOUT AUTOMATIC HAZARD
    OVERRIDE

8
GMI IN COMBUSTIBLE GAS INDICATOR MODE USES AND
FEATURES CONT.
  • MEASURES CO AND H2S, PPM RANGES
  • HEALTH SAFETY AND REGULATORY SCREENING TOOL
  • NOT TO BE USED IN LIEU OF LAB ANALYSIS

9
USING THE GMI IN COMBUSTIBLE GAS INDICATOR MODE
(CGIM)
  • Press SECOND button ONCE to turn on
  • Press second button ONCE to change range
  • Press second button TWICE to re-zero ppm range
  • Press third button to take samples
  • Press top/first button twice to turn off
  • ONE SECOND OR MORE

10
CGI Mode-Ranges
  • GAS BY VOLUME
  • TOTAL COMBUSTIBLE GAS IN PPM
  • OXYGEN BY VOLUME
  • PPM CARBON MONOXIDE (CO)
  • PPM HYDROGEN SULFIDE (H2S)
  • THEN BACK TO
  • GAS BY VOLUME

11
GAS SAMPLING EQUIPMENT
  • MAGNAHELICS
  • EVAC/TRANSFER PUMP
  • TEDLAR BAGS
  • TUBING AND CONNECTORS

12
MAGNEHELIC
13
EVAC/TRANSFER PUMP