North American Energy Standards Board - PowerPoint PPT Presentation

1 / 12
About This Presentation
Title:

North American Energy Standards Board

Description:

Bumping is not allowed during the Intraday 2 Nomination Cycle. ... Bumped parties are notified via EDI, e-mail or web page (shipper's choice) ... – PowerPoint PPT presentation

Number of Views:31
Avg rating:3.0/5.0
Slides: 13
Provided by: raemc2
Learn more at: http://www.naesb.org
Category:

less

Transcript and Presenter's Notes

Title: North American Energy Standards Board


1
North American Energy Standards Board
  • North American Energy Standards Board
  • Wholesale Gas Quadrant
  • Overview of Gas Day Standards
  • December 2004

2
North American Energy Standards BoardWGQ
Overview of Gas Day
  • The Gas Industry Standards Board (GISB), a
    precursor of the Wholesale Gas Quadrant, adopted
    a standard gas day in March 1996.
  • Similarly, in December 1997, GISB adopted an
    intraday nomination schedule, which is based from
    gas day.
  • Both sets of standards have been adopted by the
    FERC and incorporated by reference into federal
    orders.

3
North American Energy Standards BoardWGQ
Overview of Gas Day
  • The three standards of most importance in
    discussing Gas Day are NAESB WGQ Standard Nos.
    1.3.1, 1.3.2 and 1.3.41
  • NAESB WGQ Standard No. 1.3.1
  • Standard time for the gas day should be 9 a.m. to
    9 a.m. (central clock time).

4
North American Energy Standards BoardWGQ
Overview of Gas Day
  • NAESB WGQ Standard No. 1.3.2
  • (This is a six part standard)
  • All Transportation Service Providers should
    support the following standard nomination cycles
  • (i) The Timely Nomination Cycle 1130 am for
    nominations leaving control of the nominating
    party 1145 am for receipt of nominations by the
    transporter noon to send Quick Response 330 pm
    for receipt of completed confirmations by
    transporter from upstream and downstream
    connected parties 430 pm for receipt of
    scheduled quantities by shipper and point
    operator (central clock time on the day prior to
    flow).

5
North American Energy Standards BoardWGQ
Overview of Gas Day
  • NAESB WGQ Standard No. 1.3.2 (Continued)
  • (ii) The Evening Nomination Cycle 600 pm for
    nominations leaving control of the nominating
    party 615 pm for receipt of nominations by the
    transporter 630 pm to send Quick Response 900
    pm for receipt of completed confirmations by
    transporter from upstream and downstream
    connected parties 1000 pm for Transportation
    Service Provider to provide scheduled quantities
    to affected shippers and point operators, and to
    provide scheduled quantities to bumped parties
    (notice to bumped parties), (central clock time
    on the day prior to flow).

6
North American Energy Standards BoardWGQ
Overview of Gas Day
  • NAESB WGQ Standard No. 1.3.2 (continued)
  • (ii) Scheduled quantities resulting from an
    Evening Nomination that does not cause another
    Service Requester on the subject Transportation
    Service Provider to receive notice that it is
    being bumped should be effective at 900 a.m. on
    gas day and when an Evening Nomination causes
    another Service Requester on the subject
    Transportation Service Provider to receive notice
    that it is being bumped, the scheduled quantities
    should be effective at 900 a.m. on gas day.

7
North American Energy Standards BoardWGQ
Overview of Gas Day
  • NAESB WGQ Standard No. 1.3.2 (continued)
  • (iii) The Intraday 1 Nomination Cycle 1000 am
    for nominations leaving control of the nominating
    party 1015 am for receipt of nominations by the
    transporter 1030 am to send Quick Response
    100 pm for receipt of completed confirmations by
    transporter from upstream and downstream
    connected parties 200 pm for Transportation
    Service Provider to provide scheduled quantities
    to affected shippers and point operators, and to
    provide scheduled quantities to bumped parties
    (notice to bumped parties), (central clock time
    on the gas day). Scheduled quantities resulting
    from Intraday 1 Nominations should be effective
    at 500 pm on gas day.

8
North American Energy Standards BoardWGQ
Overview of Gas Day
  • NAESB WGQ Standard No. 1.3.2 (continued)
  • (iv) The Intraday 2 Nomination Cycle 500 pm for
    nominations leaving control of the nominating
    party 515 pm for receipt of nominations by the
    transporter 530 pm to send Quick Response 800
    pm for receipt of completed confirmations by
    transporter from upstream and downstream
    connected parties 900 pm for Transportation
    Service Provider to provide scheduled quantities
    to affected shippers and point operators (central
    clock time on the gas day). Scheduled quantities
    resulting from Intraday 2 Nominations should be
    effective at 900 pm. on gas day. Bumping is not
    allowed during the Intraday 2 Nomination Cycle.

9
North American Energy Standards BoardWGQ
Overview of Gas Day
  • NAESB WGQ Standard No. 1.3.2 (continued)
  • (v) For purposes of 1.3.2 ii, iii, and iv,
    "provide" shall mean, for transmittals pursuant
    to standards 1.4.x, receipt at the designated
    site, and for purposes of other forms of
    transmittal, it shall mean send or post.

10
North American Energy Standards BoardWGQ
Overview of Gas Day
NAESB WGQ Standard No. 1.3.2 (continued)
(vi)
11
North American Energy Standards BoardWGQ
Overview of Gas Day
  • NAESB WGQ Standard No. 1.3.41
  • The daily grid-wide synchronization times for
    scheduled flow are 900 a.m., 500 p.m., and 900
    p.m.

12
North American Energy Standards BoardWGQ
Overview of Gas Day
  • Bumping "Rules
  • ? Firm transportation always "bumps"
    interruptible (scheduled or flowing), except in
    the Intraday 2 Cycle.
  • Scheduled or flowing firm is never bumped,
    regardless of any respective "class" of the firm
    service involved.
  • Bumped parties are notified via EDI, e-mail or
    web page (shipper's choice)
Write a Comment
User Comments (0)
About PowerShow.com