Title: Passive House
1Passive House a Positive Net Energy Home
Katrin Klingenberg Director Passive House
Institute US PHIUS ph 217.819.7988 katrin_at_passi
vehouse.us www.passivehouse.us
21 Introduction
- 2000 Watt Society
- IEA World Energy Outlook
- Carbon Neutrality
3(No Transcript)
4IEA World Energy Outlook 2006
(Slide with permission from Keynote Presentation
Passive House Conference 2007 Dr. Wolfgang
Feist)
5 - Alternative Fuel
- Sources to
- reduce CO2
- Emissions
- 1. Nuclear
- 2. Renewables
- 3. Biofuels
- 4. Efficient Technologies
CO2 emissions estimated to increase by 56. 32
in increase still remain unaccounted for!
(Slide with permission from Keynote Presentation
Passive House Conference 2007 Dr. Wolfgang
Feist)
6Stabilizing CO2 Emissions until 2030
through 1. Passive House technology applied
for all new construction 2. Renewables II
Technological advancements in Renewable
Technologies
Passive House Technology
Renewables II
(Slide with permission from Keynote Presentation
Passive House Conference 2007 Dr. Wolfgang
Feist)
72 Basic Design Principles
- Why Passive House?
- Economic Feasibility as Core Concept
- Envelope Thermal Comfort Principles
8Why Passive House?
Optimize the House to the Heating System
9 Minimimize Losses First- Maximize Gains
(Krapmeier and Drossler 2001)
10Climate Neutrality achieved
11Image Source McKinsey Quarterly Report
12Economic Feasibility as Core Concept
- Passive House Concept Developed in the early
1990s by Dr. Wolfgang Feist and Professor Bo
Adamson as optimization of early superinsulation
work - First Passive House Prototype built in 1990 in
Kranichstein, Germany - 70-80 reduction in overall energy consumption,
90-95 reduction of heating and cooling energy - Passivhaus Institut (PHI) founded in 1996
(W. Feist 2006)
PASSIV HAUS INSTITUT
13The Small Homes Council University of Illinois,
Urbana-Champaign Wayne Schicks Team develops
the Lo-Cal House in 1974-76
Walls Double stud Walls, R-30 Roof R-40
14Harold Orr builds the Saskatchewan Conservation
House In Saskatoon, Canada in 1977
First superinsulated house that showed that
airtight construction is feasible. It is equipped
with a ventilation system with an air-to-air heat
exchanger. Peak heat load at -10 degrees
Fahrenheit is 3000 watts (10,640 Btu per
hour) Walls 12 thick, R-44 Roof R-60
15Amory and Hunter Lovins finish the Rocky Mountain
Institute in Snowmass, Colorado in 1984
Tunneling through the cost barrier Amory
Lovins
16Eliminating the Heating System for Market
Viability
Cost asymptote occurs when standard heating
system is eliminated
17Envelope and Thermal Comfort Principles
- Continuous Insulation- creating steady indoor
temperatures that wont drop below 50 degrees
without heating source - Thermal Bridge Free Construction- minimizes
condensation/ building deterioration - Compact Building Shape- excellent
surface-to-volume ratio (lt 1) - Airtightness- minimizes moisture diffusion into
wall assembly - Balanced Ventilation with Heat Recovery with
minimal Space Conditioning System - exceptional
efficiency, indoor air-quality and comfort - Optimal Solar Orientation and Shading
maximizing solar gains for winter, minimizing
gains for the summer case
7. Energy Efficient Appliances and Lighting-
highly efficient use of household
electricity 8. User Friendliness - user manuals
are recommended to be given homeowners
18Major comfort criteria
59F
68F
No !
6F
conventional house
Low surface temp discomfort
(Slide with permission from Manfred Brausem)
19Major comfort criteria
64F
68F
Yes !
6F
Passive House
min 64F surface temp comfort
Slide with permission from Manfred Brausem
20Windows Doors
Passive house window requirements for cold
climates (triple-pane, argon filled, low-e on the
right)
21- Uglass 0.54 SHGC, triple glazing
- Uframe 0.64 W/(m²K) superior insulation
- Uwindow 0.77 W/(m²K), R7.4 whole window
www.optiwin.net/mueller-en?set_languageen
www.enersign.de
22Raico Therm
Uframe 0.8 W/(m²K) Uframe 0.7 W/(m²K)
www.optiwin.net/mueller-en?set_languageen
www.raico.de
23- Passive house window
- frames, door frames and doors for cold climates
need to be insulated - Multiple lock systems for operable windows and
doors to ensure air-tightness and even wear - Excellent, multiple seals
- at sill
24Wall Construction Components
No best method, just must meet the thermal
resistance requirements of the building in the
specific climate
25Insulation Materials
- Expanded Polystyrene in various densities for
wall and under-slab insulation - Cellulose damp-spray insulation (40 times lower
embodied energy than fiberglass) - High-density spray-in fiberglass insulation
- Mineral Wool (Rock Wool)
- Vacuum Insulation
26Wall Construction Methods
Rastra (insulated Concrete form made from
recycled material) and Straw Bale Wall
Structural insulated panels Agriboard panels
(Straw boards instead of EPS)
Various Passive House applicable Wall Type
Sections
Regular insulated concrete forms
273 US Projects
- Built Examples
- Townhouses
- Apartment Buildings
28Detailing Construction
29(No Transcript)
30(No Transcript)
31(No Transcript)
32Fairview 2 Prefabricated Panels
33 34 35(No Transcript)
36Fairview 12 - 2005-07
37Tahan Residence, Berkeley - 2008
38Smith House - 2003
393 Passive Houses in Illinois Fairview 12 and
Smith House in Urbana, built in 2005-07 and 2003
40Tahan Residence, Berkeley - 2008
41Isabella Lake Passive Home in MinnesotaMike
LeBeau, Conservation Technologies
42Towards the Passive House in Duluth, MNSkyline
House Wagner-Zaun Architects, Mike LeBeau,
Conservation Technologies
43Solar Decathlon 2007
University of Darmstadt
44BioHaus School, Bemidji MN 2006
45Marthas Vineyard
46(No Transcript)
47(No Transcript)
48Planned Multifamily Projects in the US
- 70 Unit Multifamily Development in Boston,
Massachusetts - 36 Unit Townhouses and Multifamily Residences,
Urbana, Illinois - 30 Unit Multifamily Development in Yellow
Springs, Ohio - 250 Unit Multifamily/mixed Development in
Boulder, Colorado
AIA (1980)
49Kerr Avenue, Urbana IL Passive Townhouses 2006
50Kerr Avenue, Urbana IL Passive Townhouses 2006
51Kerr Avenue, Urbana IL Passive Townhouses 2006
52Kerr Avenue, Urbana IL Passive Townhouses 2006
53Kerr Avenue, Urbana IL Passive Townhouses 2006
54Kerr Avenue, Urbana IL Passive Townhouses 2006
- PHPP Multifamily Calculation
- Overall Volume can be used to certify
- building/meet PH standard
- 2. End house or worst case scenario
- apartment has to be modeled separately
- to calculate heat/cooling load
- Passive Townhouse only needs about 4kW PV array
to become a net positive energy and carbon
negative home! Cost for PH components 18,000
PV after Rebate 20,000 - 10 additional cost for PH, approx. 10 for PV
554 European built Examples
- Townhouses
- Apartment Buildings
56Nuremberg, Germany Passive Townhouses 2007
57Kranichstein, Germany Passive Townhouses 2008
58Cologne, Germany Passive Townhouses 2007
59Nuremberg, Germany Passive Apartments 2006
60Community Center built to Passive House standards
in Vorarlberg, Austria.
61Retrofitted to Passive House standards the
Drexel Weiss factory.
62European Passive House Examples
Passive House Gym Heidelberg, Germany
Passive House School Waldshut, Germany
63European Passive House Examples
Passive House Office Building Ulm, Germany
Single Family Passive House, Austria
64Energie Agentur Oberoesterreich, 75 m tall
office tower, Linz Austria
656 Summary
- Outlook
- Measured Energy Performance Comparison
- Certification
66Passive House Requirements
Requirements SI Units IP Units Annual
Heating Energy Demand 15 kWh/(m2a) 4750
Btu/ft2 (per net floor area) Annual Cooling
Energy Demand 15 kWh/(m2a) 4750
Btu/ft2 (per net floor area) Annual Total
Primary Energy Demand 120 kWh/m2 11.1
kWh/ft2 Air Leakage _at_ 50 Pa n500.6
ACH n500.1 CFM
67Passive House recommendations
- Recommendations SI Units IP
- Heat Load 10 W/m2 1 W/ft2
- Cooling Load 8 W/m2 0.8 W/ft2
-
- Envelope Insulation CA U0.26 W/m2K
R22 hr-ft2-F/Btu - Europe U0.15 W/m2K R38
hr-ft2-F/Btu - IL U0.1 W/m2K R56 hr-ft2-F/Btu
- Thermal Bridge Free Construction
- Linear Thermal Transmittance ?0.01 W/mK
?0.006 Btu/hr-ft-F - High Performance Windows
- Overall Thermal Transmittance U0.8
W/m2K U0.14 Btu/hr-ft2-F - Solar Heat Gain Coefficient g-value50 SHGC50
-
- Heat Recovery Ventilation
- Net Efficiency h75 h75
- Electric Consumption of motor 0.4 Wh/m3
0.68 Wm/ft3
68Outlook
Passive House construction has grown
exponentially in Germany and Austria and
continues with that trend. 10,000 passive house
units had been constructed by the end of 2007 and
are inhabited.
69Study done by the Florida Solar Energy Center in
conjunction with the Lawrence Berkeley National
Laboratory, Author Danny Parker
70(No Transcript)
713rd ANNUAL NORTH AMERICANPASSIVE HOUSE
CONFERENCEWHOLE gt SUMPARTS
November 7-9, 2008 Hosted at the Duluth
Entertainment Convention Center, Duluth,
Minnesota www.passivehouse.us