Title: Minimum Detectable Activity Lower Limit of Detection Specific Activity
1Minimum Detectable ActivityLower Limit of
DetectionSpecific Activity
2Definitions Specific Activity
- Specific Activity ratio of radioactivity per
unit mass of a radionuclide or labeled compound - Units Ci/mmol or Bq/mmol
- SA ยต 1/half-life
- Theoretical Specific Activity Maximum specific
activity for a carrier free isotope or compound
3Minimum Detectable ActivityLower Limit of
Detection
- LLD
- Smallest amount of activity that can be detected
for comparison with limits - Normally survey instruments
- MDA
- Smallest amount of activity that can be
quantified for comparison with limits - Normally counting equipment
4General Information Needed
- Normal background
- Counting efficiency
- Effective service area (portable survey
instruments) - Surface area monitored (i.e., 100 cm2)
- Counting time (counting equipment)
- Counting standards
5LLD
- 1.645(Rb/Tb)1/2
- LLD -----------------------
- E(A / 100 cm2)
- Rb Background count rate
- Tb Time of the background count
- E Detection efficiency of the meter
- A Effective area of the probe
6Example of LLD
- A portable survey meter is used to monitor for
fixed P-32 contamination in an active laboratory.
It is operated in a count rate mode and has a
standard Pancake GM probe attached - Data
- Rb 50 CPM (background count rate)
- Tb 1 minute
- E 25
- A 20 cm2
7Example of LLD
- A portable survey meter is used to monitor for
fixed P-32 contamination in an active laboratory.
It is operated in a count rate mode and has a
standard Pancake GM probe attached - Data
- Rb 50 CPM
- Tb 1 minute
- E 25
- A 20 cm2
1.645(Rb/Tb)1/2 LLD (DPM)
----------------------- E(A
/ 100 cm2)
Answer 233 DPM
8MDA
- ( 2.71 / TS ) 3.29 ( Rb/Tb Rb/Ts
)1/2 - MDA --------------------------------------------
-- - E(A / 100 cm2)
- Rb Background count rate
- Tb Time of the background count
- Ts Time of the sample count
- E Detection efficiency of the counter
- A Area monitored or wiped
9Example of MDA
- A liquid scintillation counter is used to monitor
for tritium contamination. A wipe test was take
over a 100 cm2 area. - Data
- Rb 25 CPM (background count rate)
- Tb 5 minutes
- Ts 5 minutes
- E 68
10Example of MDA
- A liquid scintillation counter is used to monitor
for tritium contamination. A wipe test was take
over a 100 cm2 area. - Data
- Rb 25 CPM (background count rate)
- Tb 5 minutes
- Ts 5 minutes
- E 68
( 2.71 / TS ) 3.29 ( Rb/Tb Rb/Ts
)1/2 MDA --------------------------------------
----------------
E(A / 100 cm2)
Answer 16 DPM
11Theoretical Specific Activity Examples
- Iodine-123 (13.2 h half-life)
- SA Ci/ mol
- A N l -gt N A / l -gt N A t1/2 / ln 2
- N / 6.022 x 1023 mol
- mol (A t1/2 / ln 2) / 6.022 x 1023
- 1 Ci of I-123 3.7 x 1010 dps
- mol (3.7 1010 s-1 13.2h 3600 s/h / ln
2) / 6.022 x 1023 - mol 4.2128 x 10-9 mol
- SA Ci/ mol 1 Ci / 4.2128 x 10-9 mol 2.3737
x 108 Ci/mol - SA (Iodine-123) 237370 Ci/mmol
12Theoretical Specific Activity Examples
- Iodine-123 (13.2 h half-life)
Iodine-125 (59.4d half-life)
SA Ci/ mol
A N l -gt N A / l -gt N A t1/2 / ln 2
N / 6.022 x 1023 mol
mol (A t1/2 / ln 2) / 6.022 x 1023
1 Ci of I-123 3.7 x 1010 dps
mol (3.7 1010 s-1 59.4d 24h/d 3600 s/h
/ ln 2) / 6.022 x 1023
mol 4.550 x 10-7 mol
SA Ci/ mol 1 Ci / 4.550 x 10-7 mol 2.198 x
106 Ci/mol
SA (Iodine-123) 237370 Ci/mmol
SA (Iodine-125) 2198 Ci/mmol