Validation of CSCs at FNAL - PowerPoint PPT Presentation

1 / 10
About This Presentation
Title:

Validation of CSCs at FNAL

Description:

1. We have not enough testing experience in EMU CMS project. ... relative gane value. Series2. Series3. Gas Gain non-uniformity. for ME23/2-003. Cs137 & Cosmic Rays ... – PowerPoint PPT presentation

Number of Views:35
Avg rating:3.0/5.0
Slides: 11
Provided by: yuriypisc
Category:
Tags: fnal | cscs | gane | validation

less

Transcript and Presenter's Notes

Title: Validation of CSCs at FNAL


1
Validation of CSCs at FNAL
  • Why we decided to proceed with CSC Validation
    works?
  • 1. We have not enough testing experience in EMU
    CMS project..
  • 2. At the time, when FAST sites will be able to
    test CSCs at full speed
  • FNAL already will assemble 25-40CSCs. And this
    is wrong not to have quick feedback to
    production floor
  • 3. Production Readiness Committee strongly
    recommend to test at least 20 CSCs at FNAL. in
    parallel with production

2
CRTS at LAB711 scale prototype of FAST site
Trigger Scintillating
Counters
  • Steel Hardener

Picture of FNALs CRTS - as a full scale
prototype of UF and UCLA FAST sites , during
last couple years role of LAB7 facility was test
of first several prototypes, troubleshooting
before CERN test-beam, etc
Today this is facility for CSC integration
efforts Validation of 20 first production CSCs.
3
CSC VALIDATION Tests
  • 1. HV scan of all 6 planes with/without Cs137
  • (darksource currents)
  • 2. Gas gain non-uniformity with Cs137 source
    (HV3700V)

  • 3. ZERO DEAD channels (anode cathode)
  • 4. Anode wire groups (64group/plane) efficiency
    measurements
  • 5. Single wire (group) noise rate (TDC)
  • 6. Gas gain non-uniformity with Cosmic Rays
    measurements (CFEB)

4
2. Gas gain uniformity measurementswith Cs137
source (HV3700V).
Cs137 measurements correction according
radiation profilefor one layer
(layer6,ME23/2-003)
5
Cs137 .vs. Cosmic Rays(ME23/2-003)
layer 1
layer 3
Cosmic Rays
Cs137
6
Cosmic Rays .VS. Cs137
Gas Gain non-uniformity for ME23/2-003Cs137
Cosmic Rays
Correlation between Cs137 Cosmic ray
7
4. Anode wire groups (64group/layer) efficiency
measurements
8
4. Anode wire groups (64group/layer) efficiency
measurements
9
Single wires group Noise (TDC)
10
Summary
  • Panels Production
  • Production Rate and Quality of Panels are under
    control
  • 100 of ME23/2 panels (for 148CSCs) will be done
    next week !!!
  • Next step is start production of Panels for
    PNPI(Russia) IHEP(China) CSCs Factories.
  • Chambers Assembling
  • FNAL Factory reached assembling rate 2
    chambers per month
  • 14 CSCs have been assembled at MP9 already
  • Tooling, QC/QA, trained technical personal on
    place (going through learning curves !!!)
  • CSCs Validation
  • LAB7 CRTS facility is a place for 20 CSCs
    Validation work
  • We have tested 9 CSCs already, and accumulated
    important experience for FAST Sites operation
  • Results from test of 9 CSCs shown NO SURPRISE
  • Support of Foreign Factories
  • FNAL designed, built and ship critical tooling
    to Russia and China
  • Trained at MP9(FNAL) technical personal for
    foreign factories tech. from R.C. built
    ME1/22/11/33/1 prototypes at FNAL physicists
    from RC participated at FAST sites planing and
    development