RBX Monitoring - PowerPoint PPT Presentation

About This Presentation
Title:

RBX Monitoring

Description:

Architecture of the CMS control system (functional block diagram): Run CTRL ... Wolfgang Funk -CERN CMS. fieldbus devices, PLCs, VME, HV LV power supplies ... – PowerPoint PPT presentation

Number of Views:46
Avg rating:3.0/5.0
Slides: 9
Provided by: dang179
Learn more at: http://physics.bu.edu
Category:
Tags: rbx | funk | monitoring

less

Transcript and Presenter's Notes

Title: RBX Monitoring


1
RBX Monitoring
  • RBX Production Readiness Review
  • Monitoring, Fieldbus and DCS
  • John E. Elias
  • HCAL Electronics Coordinator

2
Architecture of the CMS control system
(functional block diagram)
Selection of runtype resource manager (selection
of needed resources)
Run CTRL
ext.communication(LHC,infrastructure,magnet,
safety,)
DAQ, Trigger
Supervisory System
SCADA System
Supervision of subdetector controllers
Device Server
Request to download and read of constants and
programs
LAN (ethernet)
Classsical slow control
(OPC, others)

fieldbus (CAN, Profibus, ..)
DB
Subdetector 1 controller
fieldbus devices, PLCs, VME, HVLV power supplies
Devices

Downloading and reading of constants and
programs
Calibration events (T, laser, )
Sensors, Actuators
FE electronics
Wolfgang Funk -CERN CMS
11/02/2000
2
3
Clock and Control Module
  • One clock and control module per RBX
  • Star configuration, not daisy chained
  • Control functions
  • Download the Channel Control ASICs
  • Readback (verify) the Channel Control ASICs
  • Configure the TTC Rx
  • Readback the electronics temperatures
  • Readback the low voltage supply values
  • Execute master reset on command
  • Translate between fieldbus and RBX serial bus

4
Design Basis
  • Proven CAN bus technology
  • ATLAS Tile Calorimeter
  • ATLAS DCS
  • Radiation tolerance
  • http//atlas.web.cern.ch/Atlas/GROUPS/FRONTEND/rad
    hard.htmContent
  • http//radhome.gsfc.nasa.gov/top.htm
  • http//www.national.com/appinfo/milaero/
  • http//www.xilinx.com/partinfo/military.pdf
  • Part availability

5
Candidate Parts
6
Clock Distribution
7
Control Block Diagram
8
Summary
  • Monitor and control integrated with DCS
  • Joint Controls Project team at CERN provides
    hardware and software support for CAN bus
  • Client/server interface to the official SCADA,
    PVSS II, to be done by DUBNA collaborators
  • Engineering
  • Development platform for CAN is LabView
  • Principal challenge is implementing the
    functional block diagram using radiation tolerant
    COTS the design may not be as simple and
    elegant as it could be otherwise
  • Prototype milestone is July 2001
Write a Comment