1
Sensible Solutions for Refurbished Radiology
Diagnosis Solve Common C-Arm Issues
By Vikki Harmonay
2
Sensible Solutions for Refurbished Radiology
  • Is your C-Arm performing perfectly? Or, are you
    experiencing poor image quality, communication
    errors or other issues? Problems with C-arms The
    experts at Atlantis Worldwide put together this
    list of the most common C-Arm problems and how to
    solve them.
  • The X-ray tube could be damaged or pitted
  • The Image Intensifier might be damaged.
  • Charger failure
  • Hard drives may be full or need replacing
  • Communication error

3
Sensible Solutions for Refurbished Radiology
  • In addition to these problems, you could have
    minor issues, which can include
  • Switches failing
  • C-Arm lock up
  • Your Laser targeting device needs adjustments
  • Insulation around the cables could be degrading
  • Residue might have been imbedded in the components

4
Sensible Solutions for Refurbished Radiology
It All Starts with A Basic C-Arm Diagnosis
  • If you want to get to the bottom on your C-Arm
    image quality issues, be sure to perform basic
    diagnosis. It pretty easy, if you follow these
    steps
  • If the anatomy being imaged is above or below the
    iso-center of the image intensifier, it can give
    you high contrast or grainy images. By simply
    adjusting the height of the C-Arm, the image
    quality can be improved.
  • If your C-Arm is positioned near varying tissue
    densities, the Automatic Exposure Control will
    adjust to both densities at the same time which
    can cause a grainy or high contrast image. Try
    centering the tube to the area that is most dense
    first, then wait for the AEC to adjust to the
    body section being imaged.

5
Sensible Solutions for Refurbished Radiology
  • Use the (flouro ) boost function when imaging a
    dense body section like a lateral hip joint.
    Position the C-Arm to the densest area of the
    body first, like the L5-S1. Wait for the
    brightness/contrast to adjust and then move to
    the part being imaged.
  • You can also try re-booting the C-Arm. Just turn
    it off, count to 10 and then restart the unit.

6
Sensible Solutions for Refurbished Radiology
What To Look For While Diagnosing Your C-Arm
  • Are your images grainy, dark or light? Are the
    edges sharp or blurry? Is there a good range of
    whites, grays and blacks? Does your C-Arm render
    objects with good tonal value? If not try this
  • Use manual controls to adjust the contrast or
    brightness
  • Try using the edge enhancement feature
  • Attempt a manual technique
  • If these steps dont solve your image issues,
    its time to call in a professional for a C-Arm
    diagnosis.

7
Sensible Solutions for Refurbished Radiology
Extend The Life of Your C-Arm
  • C-Arms arent cheap. Thats why youll want to
    take these five steps to keep your up and running
    for a long time.
  • Keep your batteries charged by keeping your C-Arm
    plugged in even when its not being used. Youll
    get better technique with full generator
    batteries.
  • Have a Service Engineer perform preventative
    maintenance every year. This will help you
    recognize any developing issues, maintain solid
    image quality and catch little problems before
    they become big ones. Inspect the brakes, cables,
    wheels and all mechanical assemblies.

8
Sensible Solutions for Refurbished Radiology
  • Use protective C-Arm drapes to prevent blood and
    human bio from seeping through covers into the
    tube and electronics.
  • Clean the keyboard, C-Arm Covers, tube, image
    intensifier and power cables regularly. And dont
    forget to check and clean the fan filters. This
    can prevent dust in the electrical components. Be
    sure to check the C-Arm wheels and monitor cart
    wheels for sutures and other items that can get
    stuck. This can affect drivability and braking.
  • Protect your monitors by adjusting the sleep mode
    setting. A short sleep mode is better for units
    with CRT monitors since images can get burned in
    after a system stays on for long periods of time.

9
Sensible Solutions for Refurbished Radiology
Talk To An Expert
Is your C-Arm still performing well for you? If
not, talk to the experts at Atlantis Worldwide.
Oftentimes you can find a used or refurbished
C-Arm that delivers great performance at a much
lower price pointand you still get a terrific
warranty. Or, if youve outgrown your C-Arm, talk
to Atlantis Worldwide about trading in or selling
your current one. Were here to help. Contact Us
Today!
10
Sensible Solutions for Refurbished Radiology
Some blogs you may have missed
  1. Top 10 Tips for the Operating Theater
    Radiographer
  2. Single-Plane Or Bi-Plane Cath Labs Which Is
    Right For You?
  3. C-Arms Vascular Health
  4. Comparing The GE Innova Digital Cath Lab Family
    2100, 3100 4100
  5. Top 7 C-Arms for Your Orthopedic Practice

11
You can read this on our website
https//info.atlantisworldwide.com/blog/diagnosis-
solve-common-c-arm-issues
12
Sensible Solutions for Refurbished Radiology