Capillary is a long narrow tube used in gas chromatography specifically in zero-air gas generators. These are filled with the stationary phase and play a key role in the process of GC. It helps to pass differently through it at different temperature depending upon the boiling point of two compounds which need to be identified. – PowerPoint PPT presentation

Number of Views:4

less

Transcript and Presenter's Notes

Title: Understanding the Significance of GC Capillary Column


1
Understanding the Significance of GC Capillary
Column
  • Capillary is a long narrow tube used in gas
    chromatography specifically in zero-air gas
    generators.  These are filled with the stationary
    phase and play a key role in the process of GC.
    It helps to pass differently through it at
    different temperature depending upon the boiling
    point of two compounds which need to be
    identified.
  • The Capillary Column is of two different types
  • Packed Column,
  • Open tubular column

2
  • Understanding the types of GC capillary columns
    used in making zero-air gas generators in
    detail-
  • Packed Column,
  • Packed GC Capillary columns are usually made up
    of stainless steel, nickel, glass, or Teflon. The
    amount of pressure drop per length is very less
    in a packed column. Its inner diameter may vary
    from 1.5m to 4mm and a maximum length of 3
    meters. They are having inert solid support or
    absorbent in their coating which works as a
    support material to the column. Absorbent like
    Porous polymers and finely graded silica gel is
    used in Gas-Solid Chromatography. In Gas-liquid
    chromatography, the stationary medium is
    supported with diatomaceous earth, if the
    corrosive solute is analyzed then sieved Teflon
    steel is used.

3
  • Open tubular column
  • Fused silica or stainless with high tensile value
    is used for its construction. The length and
    diameter may vary from 5-100mm and 0.1- 0.75mm
    respectively. In this, the stationary medium is
    not coated but is on the internal part of the
    column so that the gas flow faces the least
    resistance. To protect it from outer scratches
    polyamide coating is used.
  • Understanding them more through-
  • Wall coated open tubular column, (WCOT)
  • The inner surface of the capillary column has a
    thin layer filled with liquid as a stationary
    medium whose thickness may vary from 0.05 to 3µm

4
  • Support coated open tubular column, (SCOT)
  • In this column, the inner part of the column has
    deposited a porous substance working as an
    adsorbent in the internal part of the column. The
    liquid absorbent work as support material to the
    porous substance.
  • Porous layer open tubular column, (PCOT)
  • A porous layer solid absorbent such as alumina,
    molecule sieve, or porapak is at the internal
    part of the column. These are well suited for
    light, gas, and volatile substances.
  • Fused silica open tubular column, (FCOT)
  • This column is internally covered by fused silica
    and is having a chemically bond stationary phase.

5
Understanding the Significance of GC Capillary
Columns for Zero Air Gas Generator Zero gas is
the air that has no or very less amount of
hydrocarbon. The oxidative catalyst like platinum
or palladium is used to convert air into zero
gas. It only contains less than 0.1 ppm of total
Hydrocarbon. The generator used a cellulose inlet
filter to remove all excess oil, particles, and
filters. There are many companies that deal in
the manufacturing of GC Capillary Columns,
wherein Quadrex has been the number one
manufacturer of GC Capillary Columns.
SOURCE
http//quadrexcorp.over-blog.com/2021/05/understan
ding-the-significance-of-gc-capillary-column.html
Write a Comment
User Comments (0)