Astronomy Neutrino Telescope with Abyss
environmental RESearch
http//antares.in2p3.fr/
ANTARES Status report
  • RD and site properties studies
  • Detector design
  • High energy performances
  • Lower energy studies
  • Results from a prototype line
  • Construction plans

Antoine Kouchner University Paris 7 Laboratoire
APC and CEA/Saclay for the ANTARES collaboration
HENA Workshop Paris, June 17th 2003
2
The ANTARES collaboration
  • NIKHEF, Amsterdam
  • University of Sheffield
  • University of Leeds
  • ITEP, Moscou
  • IFIC, Valencia
  • Universitat, Erlangen

Particle physicists, oceanographers,
astronomers
3
The ANTARES immersion site
4
Electro-optical cableOctober 10th 2001
5
The ANTARES Fleet
6
Sea floor survey with Cyana
Obstacle Average density 1 big object per ha
Ex historic compass
Accuracy reached for deployments 5m all objects
around detector located ?No concern
7
Water transparency
  • Scattering absorption
  • ?
  • Angular resolution effective detection surface

- Blue light (470 nm) labs 60
? 8 m lscat eff 265 ? 30 m - UV
light (370 nm) labs 26 ? 2 m
lscat eff 120 ? 4 m
Timing of photons (pulsed by LED sources)
Errors ? different measurements
Photons arrival time
(ns)
8
Demonstrator immersion
November 1999 - June 2000
Castor
Real time sonar display
Line (descending)
9
Acoustic positioning
2 cm
Relative positioning ? 5 cm confirmed with
tilt-meters
10
The Antares detector
Shore station
12 equipped lines 75 PMTs / line 5 sectors /
line 5 floors / sector 3 PMTs / floor
Optical module
14,5 m
Octagonal geometry
2475 m
Compass, tilt meter
float
Electro-optic submarine cable 40km
350 m active
Electronics containers
Readout cables
100 m
Junction box
anchor
Acoustic beacon
11
Junction box deployment December 2002
12
The optical module
Mu metal magnetic shield
Active PMT base (ISEG)
PMT 10 Hamamatsu
13
The ARS front-end digitizer
14
Storey layout electronics
to the cable
Calibration Beacon
Block of Electronics LCM
Optical Module in the glass sphere
to the cable
Hydrophone
15
Scientific Motivations
Medium Energy 10 GeV lt E? lt 1 TeV
Low Energy 10 GeV lt E? lt 100 GeV
High Energy E? gt 1 TeV
? from galactic and extra-galactic sources
neutralino search
? oscillations
Oceanography - measurements of oceanographic
parameters of deep sea - studies of
bioluminescence


16
HE expected performances
  • Angular resolution
  • Em gt 10 TeV ? 0.2º
  • Em lt 10 TeV ? n-m interaction dominated

Log(Emrec) GeV
  • Spectral resolution
  • 10 GeV lt Em lt 100 GeV muon path
  • Em gt 1 TeV ? E estimated by a factor 2-3

Log(Emtrue) GeV
17
Effective areas (rate/flux)
For n induced muons at the detector 0.01-0.07 km2
For neutrinos when entering earth 1-20 m2
known sources fit quality
Earth Opacity
18
Diffuse flux sensitivity
Includes full simulation of tracks and energy
reconstruction
MPR98
19
Point-like sources - Sky coverage
One year limit for an E-2 spectrum
ANTARES (43o N) 3.5p sr
After 1 year Antares can improve limit
for Southern hemisphere or discover something
ANTARES
Cowen, Neutrino 2002
20
Galactic microquasars
Promising sources detectable by Antares after one
year !
21
Extra-galactic fireball GRBs
Source localization and duration ? Low
background ? Soften quality cuts
Compact Object Explosion
Relativistic ejecta
Robust background estimate based on BATSE 4th
catalog burst duration / intensity 6 x 10-3 Bkg
events / year all GRB sources
Shock wave
Fermi acceleration
Different models for neutrino emission WB, MPR,
Guetta et al. 0.5 10 signal events / year
22
Search for Dark Matter
23
Atmospheric n oscillations
Looking for nm ? nX
Survival probability 1- sin2 2q sin2(1,27 L/E
Dm2) Dm2 squared masses difference eV2
L oscillation length km E nm energy
GeV q mixing angle
24
Prototype sector line
Buoy
Optical module - 10 PMT and active base - LED
calibration system
acoustic Rx 2
Local control module - Front end
electronics - positioning monitoring tools
- clock
LED beacon
Master local control module - Processor
5 storeys ? 1Gb/s ethernet to SCM
String control module - power supply
- DWDM
acoustic Rx1
acoustic Rx/Tx
Junction box
Bottom String Socket
Interlink cable
To shore
25
Sector line 20 décembre 2002
26
(No Transcript)
27
Pre-immersion tests
  • Acoustic system in a pool

acoustic Rx/Tx transducer
  • Calibration in dark room

28
Dark room results
  • Data
  • Without walk correction
  • With walk correction
  • MC
  • Reflects the PMT time transit spread

?t /?21.5 ns
?t /?21.4 ns
?t /?21.3 ns
29
Counting rate monitoring
5 mins
50 m
No short time correlation along the line Long
term monitoring foreseen until September
30
Counting rate monitoring
Z O O M
20 s
Baseline 60 kHz, correlated spikes seen within
triplets
31
Line movement orientation
As an example 40 days monitoring
These measurements allow a 10 cm accuracy on
line position estimate
32
Conclusion outlook
ANTARES has successfully met essential milestones
Collaboration forming
1996 1997 1998 1999 2000
_________________
2001 2002 2003 2004 2005