Vapor-compression refrigeration - PowerPoint PPT Presentation

1 / 10
About This Presentation
Title:

Vapor-compression refrigeration

Description:

(psychrometer) Cellulose sponge-type material expands with changes in relative humidity, which can be calibrated or used with dial indicator. – PowerPoint PPT presentation

Number of Views:404
Avg rating:3.0/5.0
Slides: 11
Provided by: MAE37
Category:

less

Transcript and Presenter's Notes

Title: Vapor-compression refrigeration


1
Vapor-compression refrigeration
Vapor-compression refrigeration and its
representation on T-s diagram (Thermodynamics 4th
ed., Cengel and Boles, Figure 10-3)
2
Question to Ponder
  • You know that you have a saturated R12 mixture
    at the exit of the expansion valve. You have both
    a temperature and a pressure gauge at that point.
    If your pressure gauge reads 400 kPa when the
    actual pressure is 390 kPa (only a small error),
    what type of substance would it look like you
    have at this point subcooled liquid, saturated
    mixture, or superheated vapor? Watch out for
    this problem whenever you have a mixture.

3
(No Transcript)
4
Hilton Air Conditioning Unit
  • Steam is added at the inlet.
  • Air is preheated before sending it through the
    evaporator. If the temperature and relative
    humidity is right, liquid will condense as the
    air passes through the evaporator.
  • Air is then reheated near the end.
  • A normal air conditioning unit would not include
    all of these processes.
  • Air flow rate is measured at the exit of the unit
    with an orifice plate and manometer.

5
Basic Equations
  • 1st law, no condensation or evaporation
  • Where is the only place in this system where
    the power input term would be kept?
  • 1st law with condensation
  • If we dont measure the temperature of the
    condensate, what would be a good estimate of the
    temperature?

6
Measuring Humidity Approaches
  • Glass thermometer with wet wick will measure
    wet-bulb temperature, which can be used with
    dry-bulb temperature to determine humidity and
    state. (psychrometer)
  • Cellulose sponge-type material expands with
    changes in relative humidity, which can be
    calibrated or used with dial indicator.
    (hygrometer)
  • Electronic Capacitance or resistance changes
    with relative humidity can be calibrated.
    Digital read-out common. (electronic hygrometer)

7
(No Transcript)
8
Humidity Meters
DMM/thermometer/ relative humidity
meters (source www.omega.com)
Sling psychrometer (becoming obsolete) Source
sciencekit.com
9
Measuring Mass Flow Rate With Pressure Drop
  • Orifice plates, flow nozzles, and venturi tubes
    are common.
  • The greater the air flow rate, the greater the
    pressure drop.
  • What general equation is used to calculate
    velocity?

Flow nozzle Source White, F.M., Fluid Mechanics
2nd Ed.
10
Examples
Orifice plate
Venturi
Rotameter (used for R12 measurement in this
experiment)
Manufacturer Airflow Measurement Systems
Source http//lambdasquare.com/
Write a Comment
User Comments (0)
About PowerShow.com