Title: GEO SOLAR HOME
1GEO SOLAR HOME
- Fossil fuels replaced by energy
- from Earth and Sun
- BIRA September 11 2006
2NW corridor of Denver metro area
3Infill site in Arvada, Colorado
4Mixed Use New Urbanism planned community
5Southern Orientation
6Energy Model
Model 1,500sf Semi-detached Townhouse
Energy Model Floor Plans
Energy Model Elevations
7Airtight, Super-insulated Shell
Blown in insulation
Airtight windows
8Raised heel trusses
Quick Specs basement R 25, ceiling R 50, walls R
25, ACH 0.15
9Passive Solar Design
Solar Access
Innovative Urban Design
GENERATION
10Thermal Mass
Model 1,500sf Semi-detached Townhouse
TILE FLOORS
THERMAL MASS
BRICK WALL
11Mobile Insulation
Double Honey Comb
Motorized
12Earth Tube Aspired Energy Recovery Ventilation
System
Westflex 250 WAC CF
13Geothermal Exchange
- Geothermal pre-heat pre-cooling for incoming
fresh air consists of 260 feet of 6 PVC pipe
buried between 6 8 feet below ground - With this system, the ERV is able to
- run continuously even if exterior temperatures
are below 28º F - achieve maximum heat recovery of 95
This winter, when exterior temperatures were 4º
F, incoming fresh air to the ERV was measured at
38º F. And in summer, 95º turns into 60º, _at_ 200
cfm.
14Community Ground Source Heat Pump for Domestic
Hot Water
240,000 Btus
- Horizontal Loop Field
- Heat Pumps 4 x 10 tons
- Tanks, Pumps, Controls
- Insulated Pipe to Homes
15Passivehaus
16Energy Efficiency Targets
17Actual Performance, November 2005 July 2006
- Warm and toasty all winter, cool this summer
- December dinner party One guest heard it was a
solar house came prepared long underwear
and flannel shirt...but with nighttime outdoor
temp at 15 after a sunny day, and with radiant
underfloor heat off, at the dining room table it
was 73offered ice packs and wet towels to help
him out - February cold snap After last sun midday
Tuesday, house held heat until midday Thursday
before underfloor heat engaged. Minus 18, home
stayed 68-70 and comfortable. - 3 a.m. and minus 7, bedrooms would stabilize at
64 with radiant heat off due to occupants
generating 400 BtU/hr.