Status of the cloud information service - PowerPoint PPT Presentation

1 / 12
About This Presentation
Title:

Status of the cloud information service

Description:

FRESCO ... FRESCO included in operational level 1 data delivery by EUMETSAT. Optional ... FRESCO product for GOME-2 data. TEMIS user workshop, Frascati, ... – PowerPoint PPT presentation

Number of Views:37
Avg rating:3.0/5.0
Slides: 13
Provided by: tem74
Category:

less

Transcript and Presenter's Notes

Title: Status of the cloud information service


1
Status of the cloud information service
  • Ping Wang, Piet Stammes, Maarten Sneep, Ronald
    van der A

2
FRESCO atmospheric model
Rsim simulated reflectance Ac cloud top
albedo As surface albedo c
effective cloud fraction T
two-way transmission
3
FRESCO atmospheric model
Rc Rs are single Rayleigh scattering
reflectances of cloudy and clear part of pixel
Tc, Ts are two way transmissions including O2
absorption and single Rayleigh scattering.
4
Cloud model
  • Effective cloud parameters
  • Middle of the cloud is retrieved
  • Useful for trace gas retrievals

5
From FRESCO to FRESCO
  • Effect on cloud information
  • cloud pressure is higher ( 60-70 hpa)
  • effective cloud fraction is a little larger
    0.02
  • chi-square is smaller
  • Effect on ozone
  • Effect of FRESCO on O3 VCD is small
  • TOSOMI 0.40 uses FRESCO (sc-v4), 0.42 uses
    FRESCO(sc-v5)
  • Effect on tropospheric NO2
  • NO2 becomes smaller
  • Difference is usually small with a few exceptions
    (with large differences)

6
Status
  • Reprocessing of O3, NO2 using FRESCO
  • Documentation up-to-date, including FRESCO
  • Version control
  • Web-access

7
Time series cloud pressure
8
Pixel sizes
9
GOME-2 cloud product
  • Status cloud information GOME-2
  • FRESCO included in operational level 1 data
    delivery by EUMETSAT
  • Optional delivery via TEMIS
  • FRESCO product for GOME-2 data

10
GOME-2 vs. SCIA cloud fraction/pressure
difference distributions
fraction
pressure
Mean difference-23 hPa, sigma108 hPa
Mean difference0.01, sigma0.12
Note SZA is larger for GOME-2 and time
difference in observation
11
OMI cloud algorithm
  • O2-O2 cloud product (OMCLDO2)
  • From validation with MODIS
  • Eff. cloud fraction abs. error 0.01 (standard
    dev. 0.10)
  • From validation with PARASOL and CloudSat
  • Cloud pressure abs. error 50 hPa (standard
    dev. 70 hPa)
  • (source Stammes et al., 2007 Sneep et al.,
    2007)
  • Daily global coverage, nadir pixel size is 13x24
    km2
  • Comparable to FRESCO

12
Possible extensions cloud product
  • GOME-2 FRESCO products
  • OMI cloud products
  • Level 3 products for climate studies (new user
    group)
Write a Comment