NPDES ENFORCEMENT SECTION - PowerPoint PPT Presentation

1 / 12
About This Presentation
Title:

NPDES ENFORCEMENT SECTION

Description:

Peak Hydraulic loads overcome the settling rate in the secondary clarifiers ... MLSS levels reduced (F/M ratio out of whack, settling characteristics changed) ... – PowerPoint PPT presentation

Number of Views:58
Avg rating:3.0/5.0
Slides: 13
Provided by: denni147
Category:

less

Transcript and Presenter's Notes

Title: NPDES ENFORCEMENT SECTION


1
NPDES ENFORCEMENT SECTION
DENNIS BENSON, BRANCH MANAGER, NPDES ENFORCEMENT
SECTION
2
Inflow and Infiltration
  • ITS NOT JUST ABOUT SSOs

3
Inflow and Infiltration
  • SOLIDS WASH OUT
  • Peak Hydraulic loads overcome the settling rate
    in the secondary clarifiers causing biomass
    (mixed liquor) to be washed out of the plant.
  • Solids in chlorine contact chamber
  • Solids in receiving stream

4
Inflow and Infiltration
  • SOLIDS WASH OUT
  • MLSS levels reduced (F/M ratio out of whack,
    settling characteristics changed)
  • BOD removal efficiencies greatly reduced
  • Large loading violations

5
Inflow and Infiltration
  • Disruption of food to microorganism ratio
  • Wash out
  • Very weak influent sewage
  • F/M disruption can result in reduced removal
    efficiencies, pin flock, or sludge bulking

6
Inflow and Infiltration
  • Loss of Alkalinity
  • Approximately 7.1 parts alkalinity are required
    to remove 1 part ammonia.
  • Disruption of nitrification process.
  • Ammonia violations until nitrification process
    restabilized.

7
Inflow and Infiltration
  • Temperature and pH Shocks
  • Inflow can bring large volumes of water to the
    treatment plant with significantly different
    temperature and/or pH than the water in the
    treatment plant. Bacteria like fairly static
    conditions, so these shocks reduce treatment
    efficiency.
  • Effluent violations
  • Violation of removal standard

8
Inflow and Infiltration
  • High Velocity of Wastewater Causes Scouring of
    Sewer Lines
  • Levels of Grit and Grease to treatment plant
    increase significantly

9
Inflow and Infiltration
  • Grit
  • Abrasion of pumps and other surfaces
  • Settles in tight layers which is difficult to
    remove and leads to loss of capacity.
  • Grease
  • Accumulates on equipment
  • Low pH values
  • Disruption of oxygen exchange

10
Inflow and Infiltration
  • Toxic Runoff
  • Inflow from certain industrial facilities can
    have high levels of toxic pollutants.
  • These toxic pollutants can pass through the
    treatment plant or cause interference.

11
Inflow and Infiltration
  • Increased energy cost
  • High volumes of water to pump and treat
  • Increased maintenance cost
  • Lots of mechanical equipment have maintenance
    schedules based upon usage
  • Shortened life of equipment

12
Inflow and Infiltration
  • Dont try to solve your SSO problem by just
    building bigger facilities. Have an active
    program to eliminate I I.
Write a Comment
User Comments (0)
About PowerShow.com