Aucun titre de diapositive - PowerPoint PPT Presentation

1 / 19
About This Presentation
Title:

Aucun titre de diapositive

Description:

Backing Store issues with very large workspaces ... shared PAT size to contain all the backing store spaces as well as TPR libraries ... – PowerPoint PPT presentation

Number of Views:44
Avg rating:3.0/5.0
Slides: 20
Provided by: Bull82
Category:

less

Transcript and Presenter's Notes

Title: Aucun titre de diapositive


1
GCOS 8 Session
TechSem 2001 Paris, March 28-30
TP8 8IT4.3 A new TP8 release Steve Stewart,
Consulting Engineer Software
2
TP8 8IT4.3
  • New Features
  • Operations
  • Administration
  • Performance
  • Misc
  • Shipped on Release SR5.1

3
Operations
  • TP8 Process Groups
  • - Process conformance enhancement
  • - Reduces net requirement for TPR pool
    virtual/real memory
  • - Allows multiple TP8 workstations to be merged
    more effectively
  • - Tailoring of processes to support subsets of
    the total application

4
Operations
  • Transparent Distributed SYSOUT and Store and
    Forward
  • - Enhance report generation of TP8 transactions
  • New Destination LID types
  • -Store_and_Forward YES
  • -DISTRIBUTED_SYSOUT YES
  • SYSOUT Destination

5
Operations
  • TP8 Pool Mix control
  • Based on TPR Type - CBL74 vs. CBL85
  • - Now will not Remove CBL85 TPR to Meet
    Wire-Count Denial of Real Memory for CBL74 TPR
    attachment
  • Reduce CBL85 TPR Attachments and Instantiations
    in a Mixed Environment
  • Improve Performance

6
Operations
  • Time Stamp Verification Applied
  • - Enhance the COPY_TPRS option
  • Spawn Job at Workstation Termination
  • - Allows automatic submission of jobs when a
    workstation is terminated

7
Administration
  • TPR Enhancements
  • - Allows more flexible administration
  • - New -RD (resets dump counter)
  • - New -SF (directs SYSOUT to temp file)
  • - New -WC (inserts wild-card characters)
  • - New -MD (modifies value of -MAXIMUM_DUMPS)
  • User Procedure for Next TPR
  • - Allow user procedure to deny request (increased
    security)

8
Administration
  • WCL for items previously configured via CX39
    alters
  • - Fully standardize features which formally
    required CX39 alters

9
Performance
  • Pre-Initialization of TP8 Workstation Structures
  • - Improved TP8 workstation start-up
  • Increased values for maximum attachments and
    Instantiations
  • - To take advantage of SR5.1 16-gigabyte feature

10
Miscellaneous
  • Automatic LOGON Command Invocation with TQ8
  • - Aid in migration from DNET/ROUT to CXI
  • Interval Control Manager Interface with Priority
    Queue Manager
  • Accounting Performance
  • - Improve accounting performance (Optional
    inhibits channel time statistics)
  • TP8 Generalized Statistics Interface
  • - Allows SIF8 to provide statistics to GCOS8 ISM
    agent

11
Miscellaneous
  • TP8/TPFF Glink Remote Forms Facility
  • - Provides remote forms support for PC endpoints
    that use Glink terminal emulation of VIP7800
    devices.
  • SUSPEND Workstation
  • LID Disable and Enable

12
Miscellaneous
  • Verbose Library List
  • - Option for displaying more detailed information
    about the TPRs
  • WMON Interface to TERM Workstation
  • - Alternative to WKS TERM
  • End of Transaction Notification
  • - Allows distinction between conversation and End
    of Transaction for correspondent

13
Miscellaneous
  • TP8 Valet Files
  • - Assist in TPR dump analysis
  • GTQS Productization
  • PST Expansion (256 processes up from 20)

14
Migration Issues
  • Need to Convert ALL the TP8 workstations at the
    same time
  • - Can run with 8IT4.2U1 on SR5.1
  • - Can NOT have a Mixture of 8IT4.2 and 8IT4.3
  • May need More House Keeping Pages (-HKP)
    in WCL

15
Migration Issues
  • Need to Configure the Max Values for Several WCL
    Items
  • - The TP1H Job will abort if Incorrect
  • Examples
  • -MAX_ACCOUNTING_FILTERS -MAX_STEPS
  • -MAX_FILE_GROUPS
    -MAX_SUB_SCHEMAS
  • -MAX_SCHEMAS
    -MAX_SOURCE_LIDS
  • - Check SYSOUT report Code 00 for more detail

16
Migration Issues
  • TPR Profiles
  • No Longer Have a default profile for the command
    file (old File Code CF new File Code F.)
  • - If the Prior WCL had profiles should be OK
  • -If the Prior WCL did NOT have Profiles and ...
  • - If the TPRs uses UFAS Conventional Files
  • - Or Other Conventional Files Access
  • - Profiles will be Required (Watch the
    Max_DB_Profiles Value)

17
Migration Issues
  • User Procedures
  • Review Current User Procedures
  • Note that CX39 is NO Longer Used
  • Use A New User Procedures Instead

18
Migration Issues
  • Migration Related Tasks
  • - Review and Re-Write User Procedures
  • - Review and Replace CX39 Alters
  • - Review and Update WCL For Current Release
  • - Find the MAX Values Needed
  • - Make release Specific Changes
  • - Setup of the New TP1H JCL etc.
  • - Review and Update TP8 Configuration Parameters

19
Migration Issues
  • 16GB (SR5.1 Feature) Issues
  • Backing Store issues with very large workspaces
  • - May need to reduce the backing store disk space
    requested via percent backing store parameter in
    WCL
  • - May need to increase the shared PAT size to
    contain all the backing store spaces as well as
    TPR libraries
  • - May use all (or a very large part) of the TEMP
    disk space in the system
Write a Comment
User Comments (0)
About PowerShow.com