Title: Diapositiva 1
118th June 2009 ENRESS CONFERENCE , BRUSSELS
Paul STEURS Export Director FAR SYSTEMS
VILLAFRANCA DI VERONA/ITALY
ENERGY MEASUREMENT MANAGEMENT DRIVE
MEASURE SAVE
2ENERGY MEASUREMENT MANAGEMENT DRIVE
MEASURE SAVE
CONTENTS OF PRESENTATION
- BUILT-UP OF THE ENERGY MEASUREMENT SYSTEM
ACCORDING EN 50463 - HARDWARE TO REALISE ENERGY MEASUREMENT
- SOFTWARE TO REALISE ENERGY MEASUREMENT
MANAGEMENT - PERSPECTIVES OF ENERGY SAVING THROUGH MEASUREMENT
3(1)
1 2 3 Energy Measurement System
V
Energy Measurement Function (EMF)
ENERGY MEASUREMENT MANAGEMENT
4 5 Communication Board to Ground
I
6 7 Data Collecting System
INTERFACING TCMS TCN(MVB,CAN,ETH)
(2)
8 9 10 Train Energy Management System
Outside of Scope of Supply FAR
(3)
(9)
ECO DRIVING Cabin Display
GPS
CATENARY VOLTAGE/CURRENT ANALYSIS
Data Handling System (DHS)
(4)
Communication System (CS)
(5)
ECO DRIVING Advanced TEMS Software
TRAIN ENERGY MANAGEMENT Basic TEMS-Tool
GSM/GPRS GSM-R
(8)
(10)
UDP-TCP/IP-HTTP GET
HOSTING SERVER Data Collecting System (DCS)
Route Plan Management
HTTP-GET FTP
Intermediate Local-server
UIC Protocol
Billing Server
(6)
(7)
4REM101 Basic Version
5LOCAL SERVER
- INTERMEDIATE STORAGE
- REDUCE ROAMING COST
- BACK UP FUNCTION
- ALLOCATED DIRECTLY TO INFRASTRUCTUR
- AVAILABLE AS APPLIANCE
6HOSTING SERVER
- DATA HOSTING
- ELABORATION OF DATA
- DATA AGREGATION
- ANALYSING TOOLS VIA WEB INTERFACE
- BACK UP
- CLUSTERING
- CAPACITY FOR UPGRADING AND NEW FUNCTIONS
- EXTERNAL ACCESS TO THE DATA THROUGH WEB
SERVICES - DATA BASE IN FRASTRUCTURE BASED ON SQL
7 BASIC TOOL SOFTWARE
INSTANT ENERGY CONSUMPTION
POWER CONSUMPTION
TOTAL ENERGY CONSUMPTION
TOTAL TIME
LOCALISATION AND STATION INFO
INSTANT ENERGY DIAGRAM
Energy (KW h)
Actual
Min/Max
7
Distance (km)
8ECO DRIVING CABIN DISPLAY
9TRAIN ENERGY MANAGEMENT SYSTEM
10CATINARY VOLTAGE CHECK
- System to check the quality of the voltage on the
Overhead Contact Line - The EMF measures voltage and current and
calculates an average voltage and current each 5
seconds. - The DHS stores each Time Reference Period (1 or 5
min.) - Uavg, the average voltage
- Umin, the minimal calculated voltage (average
during 5 seconds) - I at Umin, the current consumed in the 5 seconds
period with the lowest voltage.
11OPERATORS VIEW
12CRUCIAL POINTS OF EN50463
- ACCURACY
- TRAIN LOCALIZATION DEVICE ON BOARD
- TIME INTERVAL OF MEASUREMENT
- INTERNAL CLOCK SYNCHRONISATION
BACKGROUND FOR THESE CRUCIAL POINTS
- ENERGY PROVIDERS/DISPATCHERS
- VARIETY OF PROVIDERS / VARIETY OF TRACK USERS
- VARIETY OF TARIF ZONES
- SEASONAL TIME OF DAY ZONES
- INTEROPERABILITY
13THANKING YOU FOR YOUR ATTENTION !
AND WISHING YOU THE BEST OF SUCCESS IN SAVING
ENERGY THROUGH ENERGY MEASUREMENT AND MANAGEMENT!